Designs and Techniques That Improve the Pullout Strength of Pedicle Screws in Osteoporotic Vertebrae: Current Status

Osteoporosis is a medical condition affecting men and women of different age groups and populations. The compromised bone quality caused by this disease represents an important challenge when a surgical procedure (e.g., spinal fusion) is needed after failure of conservative treatments. Different pedicle screw designs and instrumentation techniques have been explored to enhance spinal device fixation in bone of compromised quality. These include alterations of screw thread design, optimization of pilot hole size for non-self-tapping screws, modification of the implant's trajectory, and bone cement augmentation. While the true benefits and limitations of any procedure may not be realized until they are observed in a clinical setting, axial pullout tests, due in large part to their reproducibility and ease of execution, are commonly used to estimate the device's effectiveness by quantifying the change in force required to remove the screw from the body. The objective of this investigation is to provide an overview of the different pedicle screw designs and the associated surgical techniques either currently utilized or proposed to improve pullout strength in osteoporotic patients. Mechanical comparisons as well as potential advantages and disadvantages of each consideration are provided herein.

[1]  Sean Molloy,et al.  Temperature Measurement During Polymerization of Polymethylmethacrylate Cement Used for Vertebroplasty , 2003, Spine.

[2]  T Suzuki,et al.  Improving the pullout strength of pedicle screws by screw coupling. , 2001, Journal of spinal disorders.

[3]  K. Siminoski,et al.  The accuracy of clinical kyphosis examination for detection of thoracic vertebral fractures: comparison of direct and indirect kyphosis measures. , 2011, Journal of musculoskeletal & neuronal interactions.

[4]  P. Branemark,et al.  Heat shock-induced necrosis and apoptosis in osteoblasts. , 2000, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[5]  D F Kallmes,et al.  Percutaneous polymethylmethacrylate vertebroplasty in the treatment of osteoporotic vertebral body compression fractures: technical aspects. , 1997, AJNR. American journal of neuroradiology.

[6]  S. Cho,et al.  The biomechanics of pedicle screw-based instrumentation. , 2010, The Journal of bone and joint surgery. British volume.

[7]  C. Puttlitz,et al.  Cortical bone trajectory for lumbar pedicle screws. , 2009, The spine journal : official journal of the North American Spine Society.

[8]  B. Cunningham,et al.  Straight-Forward Versus Anatomic Trajectory Technique of Thoracic Pedicle Screw Fixation: A Biomechanical Analysis , 2003, Spine.

[9]  D. Nuckley,et al.  Biomechanical analysis of pedicle screw thread differential design in an osteoporotic cadaver model. , 2012, Clinical biomechanics.

[10]  Jacques Peters,et al.  Design : an integrated approach , 1990 .

[11]  T. Steffen,et al.  Double Pedicle Screw Instrumentation in the Osteoporotic Spine: A Biomechanical Feasibility Study , 2007, Journal of spinal disorders & techniques.

[12]  H. An,et al.  Hydroxyapatite-coating of pedicle screws improves resistance against pull-out force in the osteoporotic canine lumbar spine model: a pilot study. , 2005, The spine journal : official journal of the North American Spine Society.

[13]  J. Szivek,et al.  Pullout Strengths of Cannulated and Noncannulated Cancellous Bone Screws , 1997, Clinical orthopaedics and related research.

[14]  B. Cunningham,et al.  Triangulation of Pedicular Instrumentation: A Biomechanical Analysis , 1991, Spine.

[15]  William E. Lee,et al.  Comparative analysis of posterior fusion constructs as treatments for middle and posterior column injuries: an in vitro biomechanical investigation. , 2013, Clinical biomechanics.

[16]  D. Bednar,et al.  Pullout strength of pedicle screws augmented with particulate calcium phosphate: an experimental study. , 2009, The spine journal : official journal of the North American Spine Society.

[17]  Cheng-Kung Cheng,et al.  Biomechanical analysis of different types of pedicle screw augmentation: a cadaveric and synthetic bone sample study of instrumented vertebral specimens. , 2013, Medical engineering & physics.

[18]  R. Molinari,et al.  Effects of pilot hole preparation technique on pedicle screw fixation in different regions of the osteoporotic thoracic and lumbar spine. , 2005, Journal of neurosurgery. Spine.

[19]  C. Niu,et al.  Pullout strength of pedicle screws with cement augmentation in severe osteoporosis: A comparative study between cannulated screws with cement injection and solid screws with cement pre-filling , 2011, BMC musculoskeletal disorders.

[20]  J. Goldhahn,et al.  Mechanical performance of cylindrical and dual core pedicle screws in calf and human vertebrae , 2006, Archives of Orthopaedic and Trauma Surgery.

[21]  Y. An,et al.  An expandable anchor for fixation in osteoporotic bone , 2001, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[22]  D. Moore,et al.  Restoration of Pedicle Screw Fixation With an in Situ Setting Calcium Phosphate Cement , 1997, Spine.

[23]  J Dubousset,et al.  NEW UNIVERSAL INSTRUMENTATION IN SPINAL SURGERY , 1988, Clinical orthopaedics and related research.

[24]  R. McLain,et al.  Primary Pedicle Screw Augmentation in Osteoporotic Lumbar Vertebrae: Biomechanical Analysis of Pedicle Fixation Strength , 2007, Spine.

[25]  T. Link,et al.  Axial and Tangential Fixation Strength of Pedicle Screws Versus Hooks in the Thoracic Spine in Relation to Bone Mineral Density , 2002, Spine.

[26]  S. M. Haddock,et al.  Biomechanical Evaluation of a Double-Threaded Pedicle Screw in Elderly Vertebrae , 2002, Journal of spinal disorders & techniques.

[27]  B. T. Field,et al.  A biomechanical study of intrapeduncular screw fixation in the lumbosacral spine. , 1986, Clinical orthopaedics and related research.

[28]  F. Pellisé Reviewer’s comment on: Balloon kyphoplasty for the treatment of pathological vertebral compressive fractures (I.N. Gaitanis et al.) , 2005, European Spine Journal.

[29]  R. McLain,et al.  Pedicle screw fixation strength: pullout versus insertional torque. , 2004, The spine journal : official journal of the North American Spine Society.

[30]  Zi-xiang Wu,et al.  A Study of Low Elastic Modulus Expandable Pedicle Screws in Osteoporotic Sheep , 2012, Journal of spinal disorders & techniques.

[31]  P. Augat,et al.  The impact of a distal expansion mechanism added to a standard pedicle screw on pullout resistance. A biomechanical study. , 2013, The spine journal : official journal of the North American Spine Society.

[32]  M. Helgeson,et al.  Tapping insertional torque allows prediction for better pedicle screw fixation and optimal screw size selection. , 2013, The spine journal : official journal of the North American Spine Society.

[33]  T. Webster,et al.  The influence of nano MgO and BaSO4 particle size additives on properties of PMMA bone cement , 2008, International journal of nanomedicine.

[34]  Chien-Lin Liu,et al.  Fixation strength of PMMA-augmented pedicle screws after depth adjustment in a synthetic bone model of osteoporosis. , 2012, Orthopedics.

[35]  A. Patwardhan,et al.  Balloon kyphoplasty for the treatment of pathological vertebral compressive fractures , 2005, European Spine Journal.

[36]  M. Maddocks,et al.  How practical are transmucosal fentanyl products for breakthrough cancer pain? novel use of placebo formulations to survey user opinion , 2011, BMJ Supportive & Palliative Care.

[37]  G. Sammarco,et al.  Metatarsal Osteotomy Using a Double-Threaded Compression Scew: An Adjunct to Revision Forefoot Surgery , 1989, Foot & ankle.

[38]  S. Yerby,et al.  Revision of Failed Pedicle Screws Using Hydroxyapatite Cement: A Biomechanical Analysis , 1998, Spine.

[39]  Ching-Kong Chao,et al.  Increasing Bending Strength and Pullout Strength in Conical Pedicle Screws: Biomechanical Tests and Finite Element Analyses , 2008, Journal of spinal disorders & techniques.

[40]  G. Andersson,et al.  Augmentation of Pedicle Screw Fixation Strength Using an Injectable Calcium Phosphate Cement as a Function of Injection Timing and Method , 2004, Spine.

[41]  H. Yamamoto,et al.  Mechanical strength of calcium phosphate cement in vivo and in vitro. , 1998, Biomaterials.

[42]  J. Owen,et al.  Calcium Triglyceride Versus Polymethylmethacrylate Augmentation: A Biomechanical Analysis of Pullout Strength. , 2013, Spine deformity.

[43]  J N Weinstein,et al.  Anatomic and technical considerations of pedicle screw fixation. , 1992, Clinical orthopaedics and related research.

[44]  N. Crawford,et al.  Characteristics of immediate and fatigue strength of a dual-threaded pedicle screw in cadaveric spines. , 2013, The spine journal : official journal of the North American Spine Society.

[45]  Ego Seeman,et al.  Pathogenesis of bone fragility in women and men , 2002, The Lancet.

[46]  Young-Yul Kim,et al.  Assessment of pedicle screw pullout strength based on various screw designs and bone densities-an ex vivo biomechanical study. , 2012, The spine journal : official journal of the North American Spine Society.

[47]  L. Wiltse,et al.  Anatomic Analysis of Pedicle Cortical and Cancellous Diameter as Related to Screw Size , 1989, Spine.

[48]  T. Herbert,et al.  Management of the fractured scaphoid using a new bone screw. , 1984, The Journal of bone and joint surgery. British volume.

[49]  G. Njus,et al.  The effect of pilot hole size on the insertion torque and pullout strength of self-tapping cortical bone screws in osteoporotic bone. , 2008, The Journal of trauma.

[50]  T C Hearn,et al.  Insertional Torque and Pull‐out Strengths of Conical and Cylindrical Pedicle Screws in Cadaveric Bone , 1996, Spine.

[51]  Serkan Erkan,et al.  Biomechanical Evaluation of a Novel Fenestrated Pedicle Screw Augmented With Bone Cement in Osteoporotic Spines , 2011, Spine.

[52]  Hsiang-Ho Chen,et al.  A biomechanical study of the cortex-anchorage vertebral screw. , 2003, Clinical biomechanics.

[53]  Claus Christiansen,et al.  Diagnosis of Osteoporosis , 1992, Southern medical journal.

[54]  W. Lei,et al.  Biomechanical Comparison of Expansive Pedicle Screw and Polymethylmethacrylate-augmented Pedicle Screw in Osteoporotic Synthetic Bone in Primary Implantation: An Experimental Study , 2013, Clinical spine surgery.

[55]  M. Dalstra,et al.  Titanium-alloy enhances bone-pedicle screw fixation: mechanical and histomorphometrical results of titanium-alloy versus stainless steel , 2000, European Spine Journal.

[56]  Chunhui Wu,et al.  Biomechanical Comparison of Anatomic Trajectory Pedicle Screw versus Injectable Calcium Sulfate Graft-Augmented Pedicle Screw for Salvage in Cadaveric Thoracic Bone , 2006, Journal of spinal disorders & techniques.

[57]  Reid Js,et al.  Thermally induced bone necrosis in rabbits. Relation to implant failure in humans. , 1984 .

[58]  S. Cook,et al.  Biomechanical study of pedicle screw fixation in severely osteoporotic bone. , 2004, The spine journal : official journal of the North American Spine Society.

[59]  H H BOUCHER,et al.  A method of spinal fusion. , 1959, The Journal of bone and joint surgery. British volume.

[60]  T. Washio,et al.  Structural Characteristics of the Pedicle and Its Role in Screw Stability , 1997, Spine.

[61]  T. Oxland,et al.  Enhancing Pedicle Screw Fixation in the Aging Spine With a Novel Bioactive Bone Cement: An In Vitro Biomechanical Study , 2012, Spine.

[62]  N. Crawford,et al.  Biomechanical comparison of two-level cervical locking posterior screw/rod and hook/rod techniques. , 2007, The spine journal : official journal of the North American Spine Society.

[63]  C. Niu,et al.  Pullout strength for cannulated pedicle screws with bone cement augmentation in severely osteoporotic bone: influences of radial hole and pilot hole tapping. , 2009, Clinical biomechanics.

[64]  Zi-xiang Wu,et al.  Biomechanical evaluation of an expansive pedicle screw in calf vertebrae , 2006, European Spine Journal.

[65]  Serena S. Hu,et al.  Internal fixation in the osteoporotic spine. , 1997, Spine.

[66]  C. Chao,et al.  Increase of pullout strength of spinal pedicle screws with conical core: Biomechanical tests and finite element analyses , 2005, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[67]  S. Cook,et al.  Lumbosacral fixation using expandable pedicle screws. an alternative in reoperation and osteoporosis. , 2001, The spine journal.

[68]  W. McGarry,et al.  A titanium expandable pedicle screw improves initial pullout strength as compared with standard pedicle screws. , 2011, The spine journal : official journal of the North American Spine Society.

[69]  E Schneider,et al.  Effect of cortical thickness and cancellous bone density on the holding strength of internal fixator screws , 2004, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[70]  Zhaomin Zheng,et al.  Effect of the Degree of Osteoporosis on the Biomechanical Anchoring Strength of the Sacral Pedicle Screws: An In Vitro Comparison Between Unaugmented Bicortical Screws and Polymethylmethacrylate Augmented Unicortical Screws , 2010, Spine.

[71]  B. Simpson,et al.  Cardiovascular Effects of Methylmethacrylate Cement , 1972, British medical journal.

[72]  Jessika Weiss,et al.  Machine Design An Integrated Approach , 2016 .

[73]  M. Ogon,et al.  Assessment of different screw augmentation techniques and screw designs in osteoporotic spines , 2008, European Spine Journal.

[74]  U Liljenqvist,et al.  Pullout strength of pedicle screws versus pedicle and laminar hooks in the thoracic spine. , 2001, Acta orthopaedica Belgica.

[75]  D. Pioletti,et al.  Calcium phosphate cement augmentation of cancellous bone screws can compensate for the absence of cortical fixation. , 2010, Journal of biomechanics.

[76]  B. Bai,et al.  Augmentation of Anterior Vertebral Body Screw Fixation by an Injectable, Biodegradable Calcium Phosphate Bone Substitute , 2001, Spine.

[77]  N. Kapoor,et al.  Acute adrenal insufficiency due to primary antiphospholipid antibody syndrome , 2013, Indian journal of endocrinology and metabolism.

[78]  Peter Augat,et al.  Influence of thread design on pedicle screw fixation. Laboratory investigation. , 2008, Journal of neurosurgery. Spine.

[79]  M. Kinoshita,et al.  Efficacy of novel-concept pedicle screw fixation augmented with calcium phosphate cement in the osteoporotic spine , 2005, Journal of orthopaedic science : official journal of the Japanese Orthopaedic Association.

[80]  Zi-xiang Wu,et al.  Biomechanical evaluation of fixation strength of conventional and expansive pedicle screws with or without calcium based cement augmentation. , 2011, Clinical biomechanics.

[81]  L. Lenke,et al.  The biomechanical effect of pedicle screw hubbing on pullout resistance in the thoracic spine. , 2012, The spine journal : official journal of the North American Spine Society.

[82]  D. King Internal fixation for lumbosacral fusion. , 1944, The Journal of bone and joint surgery. American volume.

[83]  D. Hukins,et al.  The effect of screw insertion angle and thread type on the pullout strength of bone screws in normal and osteoporotic cancellous bone models. , 2010, Medical engineering & physics.

[84]  F. Pfeiffer,et al.  A Comparison of Pullout Strength for Pedicle Screws of Different Designs: A Study Using Tapped and Untapped Pilot Holes , 2006, Spine.

[85]  J. Kanis,et al.  Perspective : The diagnosis of osteoporosis , 1994 .

[86]  Hiroshi Yamamoto,et al.  Enhancement of pedicle screw stability using calcium phosphate cement in osteoporotic vertebrae: in vivo biomechanical study , 2003, Journal of orthopaedic science : official journal of the Japanese Orthopaedic Association.

[87]  B. J. Doherty,et al.  A Biomechanical Study of Anterior Thoracolumbar Screw Fixation , 1998, Spine.

[88]  G. Pharr,et al.  Elastic properties of human cortical and trabecular lamellar bone measured by nanoindentation. , 1997, Biomaterials.

[89]  G. Njus,et al.  Pullout strength and load to failure properties of self-tapping cortical screws in synthetic and cadaveric environments representative of healthy and osteoporotic bone. , 2008, The Journal of trauma.

[90]  G. Rechtine,et al.  Biomechanical evaluation of pedicle screws versus pedicle and laminar hooks in the thoracic spine. , 2006, The spine journal : official journal of the North American Spine Society.

[91]  T. Albrektsson,et al.  Thermally induced bone necrosis in rabbits: relation to implant failure in humans. , 1985, Clinical orthopaedics and related research.

[92]  Yang Zhang,et al.  Surgical treatment of osteoporotic thoracolumbar compressive fractures with open vertebral cement augmentation of expandable pedicle screw fixation: a biomechanical study and a 2-year follow-up of 20 patients. , 2012, The Journal of surgical research.

[93]  Sriram Subramaniam,et al.  Electron tomography in nanoparticle imaging and analysis. , 2008, Nanomedicine.

[94]  Zi-xiang Wu,et al.  Biomechanical comparison of different techniques in primary spinal surgery in osteoporotic cadaveric lumbar vertebrae: expansive pedicle screw versus polymethylmethacrylate-augmented pedicle screw , 2011, Archives of Orthopaedic and Trauma Surgery.

[95]  Y. An,et al.  An injectable cementing screw for fixation in osteoporotic bone. , 2000, Journal of biomedical materials research.

[96]  A. Valdevit,et al.  Characteristics of pullout failure in conical and cylindrical pedicle screws after full insertion and back-out. , 2001, The spine journal : official journal of the North American Spine Society.