Practical Gamma-Ray Spectrometry

Radioactive Decay and the Origin of Gamma- and X-Radiation. Interactions of Gamma-Radiation with Matter. Semiconductor Detectors for Gamma-Ray Spectrometry. Electronics for Gamma-Ray Spectrometry. Statistics of Counting. Spectrometer Calibration. True Coincidence Summing. Computer Analysis of Gamma-Ray Spectra. Scintillation Spectrometry. Choosing, Setting Up and Checking the Specification of a Detector. Resolution: Origins and Control. Troubleshooting. Low Count Rate Systems. High Count Rate Systems. Ensuring Quality in Gamma-Ray Spectrometry. Appendices. Index.

[1]  J. Eberhardt Fano factor in silicon at 90 K , 1970 .

[2]  G. Hausser,et al.  Cosmic ray-induced background in Ge-spectrometry , 1993 .

[3]  P. Bode,et al.  A method for the correction of self-absorption of low energy photons for use in routine INAA , 1981 .

[4]  J. B. Birks,et al.  The Theory and Practice of Scintillation Counting , 1965 .

[5]  M. A. Mariscotti,et al.  A method for automatic identification of peaks in the presence of background and its application to spectrum analysis , 1967 .

[6]  S. Warren Geometrical factors in the neutron activation analysis of archaeological specimens , 1973 .

[7]  W. K. Hensley,et al.  An ultralow background germanium gamma-ray spectrometer , 1984 .

[8]  R. Gunnink New method for calibrating a Ge detector by using only zero to four efficiency points , 1990 .

[9]  R. Pehl,et al.  Effect of charge carrier trapping on germanium coaxial detector line shapes , 1987 .

[10]  D. A. Landis,et al.  Accurate determination of the ionization energy in semiconductor detectors , 1968 .

[11]  R. Gehrke,et al.  Peak position variation with source geometry in Ge(Li) detector spectra , 1975 .

[12]  Stanley G. Prussin,et al.  PHOTOPEAK METHOD FOR THE COMPUTER ANALYSIS OF GAMMA-RAY SPECTRA FROM SEMICONDUCTOR DETECTORS , 1969 .

[13]  Ron Jenkins,et al.  Quantitative X-Ray Spectrometry , 1981 .

[14]  Menno Blaauw,et al.  Multiplet deconvolution as a cause of unstable results in gamma-ray spectrometry for INAA , 1993 .

[15]  M. Blaauw The use of sources emitting coincident γ-rays for determination of absolute efficiency curves of highly efficient Ge detectors , 1993 .

[16]  G. Heusser,et al.  Study of neutron and muon background in low-level germanium gamma-ray spectrometry , 1996 .

[17]  S. Schmidt,et al.  Large, low background well-type detectors for measurements of environmental radioactivity , 1995 .

[18]  J. Verplancke Low level gamma spectroscopy: low, lower, lowest , 1992 .