Technical Note: Using experimentally determined proton spot scanning timing parameters to accurately model beam delivery time
暂无分享,去创建一个
Erik Tryggestad | Martin Bues | Michael G Herman | Yixiu Kang | James E Younkin | Jiajian Shen | Keith M Furutani | Yixiu Kang | M. Bues | K. Furutani | M. Herman | E. Tryggestad | S. Keole | Sameer R Keole | Jiajian Shen | J. Younkin
[1] Alessandra Bolsi,et al. Treatment planning and verification of proton therapy using spot scanning: initial experiences. , 2004, Medical physics.
[2] Christoph Bert,et al. Quantification of interplay effects of scanned particle beams and moving targets , 2008, Physics in medicine and biology.
[3] A J Lomax,et al. Intensity modulated proton therapy and its sensitivity to treatment uncertainties 2: the potential effects of inter-fraction and inter-field motions , 2008, Physics in medicine and biology.
[4] Radhe Mohan,et al. The M. D. Anderson proton therapy system. , 2009, Medical physics.
[5] Alfred R. Smith,et al. Vision 20/20: proton therapy. , 2009, Medical physics.
[6] Uwe Titt,et al. Commissioning of the discrete spot scanning proton beam delivery system at the University of Texas M.D. Anderson Cancer Center, Proton Therapy Center, Houston. , 2009, Medical physics.
[7] Antje-Christin Knopf,et al. Scanned proton radiotherapy for mobile targets—the effectiveness of re-scanning in the context of different treatment planning approaches and for different motion characteristics , 2011, Physics in medicine and biology.
[8] Adam Henry Aitkenhead,et al. Modelling the throughput capacity of a single-accelerator multitreatment room proton therapy centre. , 2012, The British journal of radiology.
[9] Shinichi Shimizu,et al. A Proton Beam Therapy System Dedicated to Spot-Scanning Increases Accuracy with Moving Tumors by Real-Time Imaging and Gating and Reduces Equipment Size , 2014, PloS one.
[10] Yoshiyuki Iwata,et al. Experimental studies of systematic multiple-energy operation at HIMAC synchrotron , 2014 .
[11] Xiaodong Zhang,et al. Reducing Dose Uncertainty for Spot-Scanning Proton Beam Therapy of Moving Tumors by Optimizing the Spot Delivery Sequence. , 2015, International journal of radiation oncology, biology, physics.
[12] Xiaodong Zhang,et al. Quantitative analysis of treatment process time and throughput capacity for spot scanning proton therapy. , 2016, Medical physics.
[13] Wei Liu,et al. Exploratory Study of 4D versus 3D Robust Optimization in Intensity Modulated Proton Therapy for Lung Cancer. , 2016, International journal of radiation oncology, biology, physics.