A study of titanium release into body organs following the insertion of single threaded screw implants into the mandibles of sheep.

BACKGROUND Titanium is generally considered a safe metal to use in implantation but some studies have suggested that particulate titanium may cause health problems either at the site overlying the implant or in distant organs, particularly after frictional wear of a medical prosthesis. It was the purpose of this investigation to study the levels of dissemination of titanium from threaded screw type implants following placement of single implants in sheep mandibles. METHOD Twelve sheep were implanted with a single 10x3.75mm self-tapping implant for time intervals of one, four and eight to 12 weeks. Four unoperated sheep served as controls. Regional lymph nodes, lungs, spleens and livers were dissected, frozen and subsequently analysed by Graphite Furnace Atomic Absorption Spectroscopy. RESULTS Results associated with successful implants showed no statistically significant different levels of titanium in any organ compared to controls, although some minor elevations in titanium levels within the lungs and regional lymph nodes were noted. Two implants failed to integrate and these showed higher levels of titanium in the lungs (2.2-3.8 times the mean of the controls) and regional lymph nodes (7-9.4 times the levels in controls). CONCLUSIONS Debris from a single implant insertion is at such a low level that it is unlikely to pose a health problem. Even though the number of failed implants was low, multiple failed implants may result in considerably more titanium release which can track through the regional lymph nodes. Results suggest that sheep would be an excellent model for following biological changes associated with successful and failed implants and the effect this may have on titanium release.

[1]  D. Smith,et al.  Systemic metal ion levels in dental implant patients. , 1997, The International journal of oral & maxillofacial implants.

[2]  C. Case,et al.  Widespread dissemination of metal debris from implants. , 1994, The Journal of bone and joint surgery. British volume.

[3]  S. Lugowski,et al.  Release of metal ions from dental implant materials in vivo: determination of Al, Co, Cr, Mo, Ni, V, and Ti in organ tissue. , 1991, Journal of biomedical materials research.

[4]  A. Ferguson,et al.  Trace Metal Ion Concentration in the Liver, Kidney, Spleen, and Lung of Normal Rabbits , 1962 .

[5]  J. Galante,et al.  Metal ion release from titanium‐based prosthetic segmental replacements of long bones in baboons: A long‐term study , 1984, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[6]  E. Wiley,et al.  Sinus Histiocytosis of Pelvic Lymph Nodes after Hip Replacement: A Histiocytic Proliferation Induced by Cobalt‐Chromium and Titanium , 1994, The American journal of surgical pathology.

[7]  S. Lugowski,et al.  Critical aspects of trace element analysis of tissue samples: A review , 1990 .

[8]  J. Witt,et al.  Metal wear and tissue response in failed titanium alloy total hip replacements. , 1991, The Journal of bone and joint surgery. British volume.

[9]  A. Ferguson,et al.  The ionization of metal implants in living tissues. , 1960, The Journal of bone and joint surgery. American volume.

[10]  M. Freeman,et al.  Sensitivity to titanium. A cause of implant failure? , 1991, The Journal of bone and joint surgery. British volume.

[11]  Scales Jt Black staining around titanium alloy prostheses--an orthopaedic enigma , 1991 .

[12]  M. Péoc'h,et al.  Dissemination of Wear Particles to the Liver, Spleen, and Abdominal Lymph Nodes of Patients with Hip or Knee Replacement* , 2000, The Journal of bone and joint surgery. American volume.

[13]  D. Stram,et al.  Variance components testing in the longitudinal mixed effects model. , 1994, Biometrics.

[14]  R. Suuronen,et al.  Biodegradable polylactide plates and screws in orthognathic surgery: technical note. , 1998, Journal of cranio-maxillo-facial surgery : official publication of the European Association for Cranio-Maxillo-Facial Surgery.

[15]  F W Neukam,et al.  Metal release from titanium fixtures during placement in the mandible: an experimental study. , 1993, The International journal of oral & maxillofacial implants.

[16]  S. Steinemann,et al.  Titanium deposition in regional lymph nodes after insertion of titanium screw implants in maxillofacial region. , 1994, International journal of oral and maxillofacial surgery.

[17]  B. Moretti,et al.  Hydroxyapatite coated with hepatocyte growth factor (HGF) stimulates human osteoblasts in vitro , 2000 .

[18]  R. Schmelzeisen,et al.  Ultrastructural findings in soft tissues adjacent to titanium plates used in jaw fracture treatment. , 1993, International journal of oral and maxillofacial surgery.

[19]  J. Galante,et al.  Release and excretion of metal in patients who have a total hip-replacement component made of titanium-base alloy. , 1991, The Journal of bone and joint surgery. American volume.

[20]  K. Ooya,et al.  Titanium lymph node pigmentation in the reconstruction plate system of a mandibular bone defect. , 1993, Oral surgery, oral medicine, and oral pathology.

[21]  A. Ferguson,et al.  Characteristics of Trace Ions Released from Embedded Metal Implants in the Rabbit , 1962 .