Organ and effective doses in newborn patients during helical multislice computed tomography examination

In this study, two computational phantoms of the newborn patient were used to assess individual organ doses and effective doses delivered during head, chest, abdomen, pelvis, and torso examinations using the Siemens SOMATOM Sensation 16 helical multi-slice computed tomography (MSCT) scanner. The stylized phantom used to model the patient anatomy was the revised ORNL newborn phantom by Han et al (2006 Health Phys.90 337). The tomographic phantom used in the study was that developed by Nipper et al (2002 Phys. Med. Biol. 47 3143) as recently revised by Staton et al (2006 Med. Phys. 33 3283). The stylized model was implemented within the MCNP5 radiation transport code, while the tomographic phantom was incorporated within the EGSnrc code. In both codes, the x-ray source was modelled as a fan beam originating from the focal spot at a fan angle of 52 degrees and a focal-spot-to-axis distance of 57 cm. The helical path of the source was explicitly modelled based on variations in collimator setting (12 mm or 24 mm), detector pitch and scan length. Tube potentials of 80, 100 and 120 kVp were considered in this study. Beam profile data were acquired using radiological film measurements on a 16 cm PMMA phantom, which yielded effective beam widths of 14.7 mm and 26.8 mm for collimator settings of 12 mm and 24 mm, respectively. Values of absolute organ absorbed dose were determined via the use of normalization factors defined as the ratio of the CTDI(100) measured in-phantom and that determined by Monte Carlo simulation of the PMMA phantom and ion chamber. Across various technique factors, effective dose differences between the stylized and tomographic phantoms ranged from +2% to +9% for head exams, -4% to -2% for chest exams, +8% to +24% for abdominal exams, -16% to -12% for pelvic exams and -7% to 0% for chest-abdomen-pelvis (CAP) exams. In many cases, however, relatively close agreement in effective dose was accomplished at the expense of compensating errors in individual organ dose. Per cent differences in organ dose between the stylized and tomographic phantoms at 120 kVp and 12 mm collimator setting ranged from -25% (skin) to +164% (muscle) for head exams, -92% (thyroid) to +98% (ovaries) for chest exams, -144% (uterus) to +112% (ovaries) for abdominal exams, -98% (SI wall) to +20% (thymus) for pelvic exams and -60% (extrathoracic airways) to +13% (ovaries) for CAP exams. Better agreement was seen between the two phantom types for organs entirely within the scan field. In these cases, corresponding per cent differences in organ absorbed dose did not vary more than 17%. For all scans, the effective dose was found to range approximately 1-13 mSv across the scan parameters and scan regions. The largest effective dose occurred for CAP scans at 120 kVp.

[1]  W Huda,et al.  An approach for the estimation of effective radiation dose at CT in pediatric patients. , 1997, Radiology.

[2]  Wesley E Bolch,et al.  A tomographic physical phantom of the newborn child with real-time dosimetry. II. Scaling factors for calculation of mean organ dose in pediatric radiography. , 2006, Medical physics.

[3]  Wesley E Bolch,et al.  REVISIONS TO THE ORNL SERIES OF ADULT AND PEDIATRIC COMPUTATIONAL PHANTOMS FOR USE WITH THE MIRD SCHEMA , 2006, Health physics.

[4]  D. Brenner,et al.  Estimated risks of radiation-induced fatal cancer from pediatric CT. , 2001, AJR. American journal of roentgenology.

[5]  W E Bolch,et al.  Tomographic physical phantom of the newborn child with real-time dosimetry I. Methods and techniques for construction. , 2006, Medical physics.

[6]  P C Shrimpton,et al.  Influence of patient age on normalized effective doses calculated for CT examinations. , 2002, The British journal of radiology.

[7]  W E Bolch,et al.  A comparison of newborn stylized and tomographic models for dose assessment in paediatric radiology. , 2003, Physics in medicine and biology.

[8]  K. F. Eckerman,et al.  Specific absorbed fractions of energy at various ages from internal photon sources: 6, Newborn , 1987 .

[9]  J. F. Briesmeister MCNP-A General Monte Carlo N-Particle Transport Code , 1993 .

[10]  M Caon,et al.  A comparison of radiation dose measured in CT dosimetry phantoms with calculations using EGS4 and voxel-based computational models. , 1997, Physics in medicine and biology.

[11]  C. Proukakis,et al.  Computed Tomography Dosimetry in Children , 2000 .

[12]  Icrp Age-dependent doses to members of the public from intake of radionuclides: Part 4 Inhalation dose coefficients , 1995, Annals of the ICRP.

[13]  J. Valentin Basic anatomical and physiological data for use in radiological protection: reference values , 2002, Annals of the ICRP.

[14]  J J DeMarco,et al.  A Monte Carlo-based method to estimate radiation dose from spiral CT: from phantom testing to patient-specific models , 2003, Physics in medicine and biology.

[15]  Division on Earth Health Risks from Exposure to Low Levels of Ionizing Radiation: BEIR VII Phase 2 , 2006 .

[16]  W. Huda,et al.  Radiation doses to infants and adults undergoing head CT examinations. , 2001, Medical physics.

[17]  W Huda,et al.  Effective doses to patients undergoing thoracic computed tomography examinations. , 2000, Medical physics.

[18]  I. Kawrakow Accurate condensed history Monte Carlo simulation of electron transport. I. EGSnrc, the new EGS4 version. , 2000, Medical physics.

[19]  David J. Brenner,et al.  Estimating cancer risks from pediatric CT: going from the qualitative to the quantitative , 2002, Pediatric Radiology.

[20]  C L Chapple,et al.  Effective dose in paediatric computed tomography. , 2002, Physics in medicine and biology.

[21]  Maria Zankl,et al.  Organ Doses for Children from Computed Tomographic Examinations , 1995 .

[22]  M Caon,et al.  An EGS4-ready tomographic computational model of a 14-year-old female torso for calculating organ doses from CT examinations. , 1999, Physics in medicine and biology.

[23]  G Drexler,et al.  The construction of computer tomographic phantoms and their application in radiology and radiation protection , 1988, Radiation and environmental biophysics.

[24]  M. Cristy,et al.  Active bone marrow distribution as a function of age in humans. , 1981, Physics in medicine and biology.

[25]  W E Bolch,et al.  Creation of two tomographic voxel models of paediatric patients in the first year of life. , 2002, Physics in medicine and biology.

[26]  D A Pierce,et al.  Studies of the mortality of atomic bomb survivors. Report 12, Part I. Cancer: 1950-1990. , 1996, Radiation research.

[27]  L. Wang,et al.  Development of tissue-simulating optical phantoms: poly-N-isopropylacrylamide solution entrapped inside a hydrogel. , 1999, Physics in medicine and biology.