Ring cusp discharge chamber performance optimization

An experimental study of the effects of discharge chamber length and the locations of the anode, cathode and ring cusp within the chamber on the performance of an 8 cm dia. ring cusp thruster is described. As these lengths and positions are varied the changes induced in plasma ion energy costs, extracted ion fractions and ion beam profiles are measured. Results show that the anode may be positioned at any location along an 'optimum virtual anode' magnetic field line and minimum plasma ion energy costs will result. The actual location of this field line is related to a 'virtual cathode' magnetic field line that is defined by the cathode position. The magnetic field has to be such that the virtual anode field line intersects the grids at the outermost ring of grid holes to maximize the extracted ion fraction and flatten the ion beam profile. Discharge chamber lengths that were as small as possible in the test apparatus yielded the lowest extracted ion fractions.