Development of titanium oxide based 12μm pixel pitch uncooled infrared detector

Pixel size reduction in an uncooled infrared detector plays a crucial role in determining significant attributes such as size, weight, and cost. Without a loss in sensitivity, however, it is challenging to develop an uncooled infrared detector that has the pixel pitch of 12 μm and below. Especially, there has been a limitation of an uncooled focal plane array (FPA) with a single-level design, which has to accomplish both functions of absorption and heat conduction in a single layer and thus compromise the sensitivity of FPA. A selective etching process of a resistive material, titanium oxide, on the connecting legs in the microbolometer FPA has been developed to overcome the limitation and increase the sensitivity of the single-level design FPA. Furthermore, structural stress modulation has been applied to ensure the mechanical robustness of the developed FPA. Here, we present a 12 μm single-level design FPA using a titanium oxide as a resistive material of microbolometer FPA. High-resolution detectors with an array size of 640 x 480 pixels (VGA format) and 1024 x 768 pixels (XGA format) have been developed, and the noise equivalent temperature difference (NETD) and time constant for the VGA detector are 40.5 mK and 8.3 msec, respectively. Thermal image obtained by the 12 μm XGA detector shows excellent image quality and fine resolution.

[1]  P. Kruse,et al.  Integrated uncooled infrared detector imaging arrays , 1992, Technical Digest IEEE Solid-State Sensor and Actuator Workshop.

[2]  T. Hitosugi,et al.  Wet Etching of Amorphous TiO2 Thin Films Using H3PO4–H2O2 Aqueous Solution , 2013 .

[3]  Keedong Yang,et al.  Investigations of reactively sputtered TiO2-δ films for microbolometer applications , 2008, Security + Defence.

[4]  George D. Skidmore,et al.  DRS uncooled VOx infrared detector development and production status , 2010, Defense + Commercial Sensing.

[5]  A. Rogalski,et al.  Challenges of small-pixel infrared detectors: a review , 2016, Reports on progress in physics. Physical Society.

[6]  George D. Skidmore,et al.  Uncooled microbolometers at DRS and elsewhere through 2013 , 2014, Sensing Technologies + Applications.

[7]  Naoki Oda,et al.  New thermally isolated pixel structure for high-resolution (640×480) uncooled infrared focal plane arrays , 2006 .

[8]  Sang-Gook Kim,et al.  Design and fabrication of a high-fill-factor microbolometer using double sacrificial layers , 1999, Defense, Security, and Sensing.

[9]  Jean-Louis Ouvrier-Buffet,et al.  Latest pixel size reduction of uncooled IR-FPA at CEA, LETI , 2012, Other Conferences.

[10]  Jay Vizgaitis,et al.  Uncooled long-wave infrared small pixel focal plane array and system challenges , 2013 .

[11]  Jun Wang,et al.  Focal plane array detectors with micro-bolometer structure and its application in IR and THz imaging , 2016, Other Conferences.