FLOW-INJECTION ENZYME-IMMUNOASSAY FOR HUMAN-IGG BY USING ENHANCED CHEMI-LUMINESCENCE REACTION FOR HORSERADISH-PEROXIDASE LABEL QUANTITATION

Abstract A flow-injection sandwich enzyme immunoassay for human IgG as model antigen by using horseradish peroxidase as label, polystyrene beads as solid support, and the enhanced chemiluminescence reaction for peroxidase quantitation is described. the kinetics of antigen—immobilized antibody interaction has been studied and the quantitative time-concentration ranges of reactions have been estimated. Each of the two immunochemical steps of analysis have been pursued in the kinetic regime. the time for each immunochemical step was reduced to 2–3 min. the enhanced luminescent reaction involving luminol and p-iodophenol as substrates was used to detect the peroxidase label. the conditions for chemiluminescent reaction were optimized. the detection limit for peroxidase in a 3 min assay was 5–10−16 moles/tube. the detection limit for IgG, in the developed immunoassay, is 10−9 M, the overall time of the assay being 5–10 min.

[1]  J. Freytag,et al.  A highly sensitive affinity-column-mediated immunometric assay, as exemplified by digoxin. , 1984, Clinical chemistry.

[2]  P. Nakane,et al.  PEROXIDASE-LABELED ANTIBODY A NEW METHOD OF CONJUGATION , 1974, The journal of histochemistry and cytochemistry : official journal of the Histochemistry Society.

[3]  Paul J. Worsfold,et al.  A model immunoassay using automated flow injection analysis , 1984 .

[4]  J. Hinds,et al.  Ligand displacement immunoassay--demonstration of its use for the measurement of serum phenobarbital and phenytoin. , 1985, Clinica chimica acta; international journal of clinical chemistry.

[5]  P. Tijssen,et al.  Practice and theory of enzyme immunoassays , 1985 .

[6]  Akio Tsuji,et al.  Enzymatic immunoassay of α-fetoprotein, insulin and 17-α-hydroxyprogesterone base on chemiluminescence in a flow-injection system , 1985 .

[7]  L. Kricka,et al.  Enhanced luminescence procedure for sensitive determination of peroxidase-labelled conjugates in immunoassay , 1983, Nature.

[8]  Jaromir Růžička,et al.  Flow injection analysis , 1981 .

[9]  J. Schölmerich,et al.  Bioluminescence and chemiluminescence - new perspectives , 1987 .

[10]  J. Freytag,et al.  Affinity-column-mediated immunoenzymometric assays: influence of affinity-column ligand and valency of antibody-enzyme conjugates. , 1984, Clinical chemistry.

[11]  D Rodbard,et al.  Computerized optimization of radioimmunoassays for hCG and estradiol: an experimental evaluation. , 1978, Analytical biochemistry.