Image quality and dose efficiency of high energy phase sensitive x-ray imaging: phantom studies.

The goal of this preliminary study was to perform an image quality comparison of high energy phase sensitive imaging with low energy conventional imaging at similar radiation doses. The comparison was performed with the following phantoms: American College of Radiology (ACR), contrast-detail (CD), acrylic edge and tissue-equivalent. Visual comparison of the phantom images indicated comparable or improved image quality for all phantoms. Quantitative comparisons were performed through ACR and CD observer studies, both of which indicated higher image quality in the high energy phase sensitive images. The results of this study demonstrate the ability of high energy phase sensitive imaging to overcome existing challenges with the clinical implementation of phase contrast imaging and improve the image quality for a similar radiation dose as compared to conventional imaging near typical mammography energies. In addition, the results illustrate the capability of phase sensitive imaging to sustain the image quality improvement at high x-ray energies and for breast simulating phantoms, both of which indicate the potential to benefit fields such as mammography. Future studies will continue to investigate the potential for dose reduction and image quality improvement provided by high energy phase sensitive imaging.

[1]  J. Bushberg The Essential Physics of Medical Imaging , 2001 .

[2]  K. Nugent,et al.  Quantitative Phase Imaging Using Hard X Rays. , 1996, Physical review letters.

[3]  Li Zhang,et al.  Low dose reconstruction algorithm for differential phase contrast imaging. , 2011, Journal of X-ray science and technology.

[4]  The development of mammography. , 2006, Physics in medicine and biology.

[5]  L. Tabár,et al.  Beyond randomized controlled trials , 2001, Cancer.

[6]  Hong Liu,et al.  The characterization of a phase contrast x-ray imaging prototype , 2007, SPIE BiOS.

[7]  Akira Furukawa,et al.  The First Trial of Phase Contrast Imaging for Digital Full-Field Mammography Using a Practical Molybdenum X-Ray Tube , 2005, Investigative radiology.

[8]  Hiroshi Fujita,et al.  Evaluation of edge effect due to phase contrast imaging for mammography. , 2005, Medical physics.

[9]  R. Aufrichtig,et al.  Comparison of low contrast detectability between a digital amorphous silicon and a screen-film based imaging system for thoracic radiography. , 1999, Medical physics.

[10]  E. Thurfjell,et al.  Breast cancer survival rates with mammographic screening: similar favorable survival rates for women younger and those older than 50 years. , 1996, Radiology.

[11]  Hong Liu,et al.  Image quality comparison of high-energy phase contrast x-ray images with low-energy conventional images: phantom studies , 2010, BiOS.

[12]  D. Dance Monte Carlo calculation of conversion factors for the estimation of mean glandular breast dose. , 1990, Physics in medicine and biology.

[13]  Aimin Yan,et al.  X-ray phase-attenuation duality and phase retrieval. , 2005, Optics letters.

[14]  V. N. Ingal,et al.  Phase mammography--a new technique for breast investigation. , 1998, Physics in medicine and biology.

[15]  G. Barnes,et al.  Spectral dependence of glandular tissue dose in screen-film mammography. , 1991, Radiology.

[16]  David R Pickens,et al.  Quantification of the effect of system and object parameters on edge enhancement in phase-contrast radiography. , 2003, Medical physics.

[17]  S. Wilkins,et al.  Phase-contrast imaging using polychromatic hard X-rays , 1996, Nature.

[18]  Bruno O. Shubert,et al.  Random variables and stochastic processes , 1979 .

[19]  W. Mendenhall,et al.  Statistics for engineering and the sciences , 1984 .

[20]  X Liu,et al.  Comparison of an amorphous silicon/cesium iodide flat-panel digital chest radiography system with screen/film and computed radiography systems--a contrast-detail phantom study. , 2001, Medical physics.

[21]  E Castelli,et al.  Low-dose phase contrast x-ray medical imaging. , 1998, Physics in medicine and biology.

[22]  R E Hendrick,et al.  Standardization of image quality and radiation dose in mammography. , 1990, Radiology.

[23]  Xizeng Wu,et al.  X-Ray cone-beam phase tomography formulas based on phase-attenuation duality. , 2005, Optics Express.

[24]  Hong Liu,et al.  Phantom imaging with a prototype phase contrast radiography system , 2006, Saratov Fall Meeting.

[25]  S. Moss A trial to study the effect on breast cancer mortality of annual mammographic screening in women starting at age 40 , 1999, Journal of medical screening.

[26]  Hong Liu,et al.  Clinical implementation of x-ray phase-contrast imaging: theoretical foundations and design considerations. , 2003, Medical physics.

[27]  R. Larsen,et al.  An introduction to mathematical statistics and its applications (2nd edition) , by R. J. Larsen and M. L. Marx. Pp 630. £17·95. 1987. ISBN 13-487166-9 (Prentice-Hall) , 1987, The Mathematical Gazette.

[28]  S. Shapiro,et al.  Periodic breast cancer screening in reducing mortality from breast cancer. , 1971, JAMA.

[29]  L L Fajardo,et al.  Contrast-detail detectability analysis: comparison of a digital spot mammography system and an analog screen-film mammography system. , 1997, Academic radiology.

[30]  F R Verdun,et al.  Quantitative characterization of edge enhancement in phase contrast x-ray imaging. , 2004, Medical physics.

[31]  Aimin Yan,et al.  An attenuation-partition based iterative phase retrieval algorithm for in-line phase-contrast imaging. , 2008, Optics express.

[32]  William Mendenhall,et al.  Statistics for Engineering and the Sciences (5th Edition) , 2006 .

[33]  Wei R. Chen,et al.  Comparison of a CMOS-based and a CCD-based digital x-ray imaging system: Observer studies , 2005, J. Electronic Imaging.

[34]  A. Momose,et al.  Phase-contrast radiographs of nonstained rat cerebellar specimen. , 1995, Medical physics.

[35]  R. Gold The evolution of mammography. , 1988, Radiologic clinics of North America.

[36]  N. Dyson,et al.  X-rays in atomic and nuclear physics , 1990 .

[37]  Xizeng Wu,et al.  A phantom-based calibration method for digital x-ray tomosynthesis. , 2012, Journal of X-ray science and technology.

[38]  Hong Liu,et al.  A convenient alignment approach for x-ray imaging experiments based on laser positioning devices. , 2008, Medical physics.

[39]  Xizeng Wu,et al.  Preliminary Feasibility Study of an In-line Phase Contrast X-Ray Imaging Prototype , 2008, IEEE Transactions on Biomedical Engineering.

[40]  Matthew T. Freedman,et al.  Phase contrast digital mammography using molybdenum x-ray: clinical implications in detectability improvement , 2003, SPIE Medical Imaging.

[41]  G. Barnes,et al.  Normalized average glandular dose in molybdenum target-rhodium filter and rhodium target-rhodium filter mammography. , 1994, Radiology.

[42]  Ronald R Price,et al.  Quantification of the effect of kvp on edge-enhancement index in phase-contrast radiography. , 2002, Medical physics.

[43]  Xizeng Wu,et al.  Phase retrieval from one single phase contrast x-ray image. , 2009, Optics express.

[44]  Hong Liu,et al.  Performance analysis of the attenuation-partition based iterative phase retrieval algorithm for in-line phase-contrast imaging. , 2010, Optics express.

[45]  Xizeng Wu,et al.  A general theoretical formalism for X-ray phase contrast imaging. , 2003, Journal of X-ray science and technology.

[46]  S. Shapiro,et al.  Periodic screening for breast cancer: the HIP Randomized Controlled Trial. Health Insurance Plan. , 1997, Journal of the National Cancer Institute. Monographs.

[47]  R. Edward Hendrick,et al.  Mammography quality control manual , 1999 .

[48]  K D Paulsen,et al.  Contrast-detail analysis for detection and characterization with near-infrared diffuse tomography. , 2000, Medical physics.

[49]  P. Cloetens,et al.  Quantitative phase tomography of Arabidopsis seeds reveals intercellular void network , 2006, Proceedings of the National Academy of Sciences.

[50]  Richard J. Fitzgerald,et al.  Phase‐Sensitive X‐Ray Imaging , 2000 .

[51]  C. J. Kotre,et al.  Phase contrast enhancement of x-ray mammography: a design study. , 1999, Physics in medicine and biology.

[52]  A. Karellas,et al.  Breast cancer imaging: a perspective for the next decade. , 2008, Medical physics.

[53]  Hong Liu,et al.  The effects of x-ray beam hardening on detective quantum efficiency and radiation dose. , 2011, Journal of X-ray science and technology.

[54]  R. Hendrick,et al.  Benefit of screening mammography in women aged 40-49: a new meta-analysis of randomized controlled trials. , 1997, Journal of the National Cancer Institute. Monographs.

[55]  Bruce H. Hasegawa,et al.  The Physics of Medical X-Ray Imaging , 1987 .

[56]  J. Boone,et al.  Glandular breast dose for monoenergetic and high-energy X-ray beams: Monte Carlo assessment. , 1999, Radiology.