Limitations of stimulated echo acquisition mode (steam) techniques in cardiac applications

Stimulated echoes are widely used for imaging functional tissue parameters such as diffusion coefficient, perfusion, and flow rates. They are potentially interesting for the assessment of various cardiac functions. However, severe limitations of the stimulated echo acquisition mode occur, which are related to the special dynamic properties of the beating heart and flowing blood. To the well‐known signal decay due to longitudinal relaxation and through‐plane motion between the preparation and the read‐out period of the stimulated echoes, additional signal loss is often observed. As the prepared magnetization is fixed with respect to the tissue, this signal loss is caused by the tissue deformation during the cardiac cycle, which leads to a modification of the modulation frequency of the magnetization. These effects are theoretically derived and corroborated by phantom and in vivo experiments.

[1]  J. Frahm,et al.  High‐speed STEAM MRI of the human heart , 1991, Magnetic resonance in medicine.

[2]  Jens Frahm,et al.  Diffusion imaging using stimulated echoes , 1991, Magnetic resonance in medicine.

[3]  Jens Frahm,et al.  Stimulated echo imaging , 1985 .

[4]  R. Miller,et al.  Left Ventricular Diastolic Performance At Rest and During Exercise in Patients With Coronary Artery Disease: Assessment with First‐pass Radionuclide Angiography , 1981, Circulation.

[5]  P Boesiger,et al.  True myocardial motion tracking , 1994, Magnetic resonance in medicine.

[6]  P Boesiger,et al.  Evaluation of Left Ventricular Segmental Wall Motion in Hypertrophic Cardiomyopathy With Myocardial Tagging , 1992, Circulation.

[7]  J. Pekar,et al.  Imaging of diffusion and microcirculation with gradient sensitization: Design, strategy, and significance , 1991, Journal of magnetic resonance imaging : JMRI.

[8]  T. Foster,et al.  A review of normal tissue hydrogen NMR relaxation times and relaxation mechanisms from 1-100 MHz: dependence on tissue type, NMR frequency, temperature, species, excision, and age. , 1984, Medical physics.

[9]  R R Edelman,et al.  In vivo measurement of water diffusion in the human heart , 1994, Magnetic resonance in medicine.

[10]  E. Zerhouni,et al.  Quantification of and Correction for Left Ventricular Systolic Long‐Axis Shortening by Magnetic Resonance Tissue Tagging and Slice Isolation , 1991, Circulation.

[11]  J Hennig Generalized MR interferography , 1990, Magnetic resonance in medicine.

[12]  Acquisition of spin echo and stimulated echo by a single sequence: application to MRI of diffusion. , 1994, Magnetic resonance imaging.

[13]  S. Maier,et al.  Improved myocardial tagging contrast , 1993, Magnetic resonance in medicine.

[14]  K R Karsch,et al.  [Quantitative segmental analysis of wall function of the right ventricle in probands with healthy hearts]. , 1988, Zeitschrift fur Kardiologie.

[15]  D. Cory,et al.  Measurement of translational displacement probabilities by NMR: An indicator of compartmentation , 1990, Magnetic resonance in medicine.

[16]  D. Burstein,et al.  MR imaging of coronary artery flow in isolated and in vivo hearts , 1991, Journal of magnetic resonance imaging : JMRI.

[17]  Jens Frahm,et al.  Flow NMR imaging using stimulated echoes , 1986 .

[18]  M B Scheidegger,et al.  Coronary artery imaging in multiple 1-sec breath holds. , 1993, Magnetic resonance imaging.

[19]  Guang-Zhong Yang,et al.  Helical and Retrograde Secondary Flow Patterns in the Aortic Arch Studied by Three‐Directional Magnetic Resonance Velocity Mapping , 1993, Circulation.

[20]  Jens Frahm,et al.  Multiple chemical-shift-selective NMR imaging using stimulated echoes , 1985 .

[21]  L. Axel,et al.  MR imaging of motion with spatial modulation of magnetization. , 1989, Radiology.

[22]  R B Buxton,et al.  The diffusion sensitivity of fast steady‐state free precession imaging , 1993, Magnetic resonance in medicine.

[23]  P van Gelderen,et al.  Water diffusion and acute stroke , 1994, Magnetic resonance in medicine.

[24]  E. Hiltbrand,et al.  Self-referencing subtractive angiography by modified stimulated echo in magnetic resonance imaging. , 1989, Physics in medicine and biology.

[25]  P Mansfield,et al.  Spatial mapping of the chemical shift in NMR , 1983, Magnetic resonance in medicine.

[26]  Jens Frahm,et al.  Self-diffusion NMR imaging using stimulated echoes , 1985 .

[27]  J. Shaver,et al.  Left ventricular diastolic filling in patients with coronary artery disease and normal left ventricular function. , 1985, American heart journal.

[28]  W. O'Dell,et al.  Calculation of three‐dimensional left ventricular strains from biplanar tagged MR images , 1992, Journal of magnetic resonance imaging : JMRI.

[29]  R Tischler,et al.  MR imaging using stimulated echoes (STEAM). , 1986, Radiology.

[30]  C. S. Poon,et al.  Projection flow imaging by bolus tracking using stimulated echoes , 1989, Magnetic resonance in medicine.