Safety considerations for magnetic fields of 10 mT to 100 mT amplitude in the frequency range of 10 kHz to 100 kHz for magnetic particle imaging

Abstract Magnetic particle imaging (MPI) is a new imaging modality using oscillating magnetic fields in the frequency range of 10 kHz to 100 kHz. The duration of data acquisition becomes smaller, and signal-to-noise ratio improves if the amplitude of these fields is increased – technically amplitudes of up to 100 mT might be feasible for human-sized systems. On the other hand, with increasing field strength, adverse health effects must be expected: oscillating magnetic fields can stimulate nerves and muscle and heat up tissue. Thresholds for stimulation with magnetic fields in this frequency range are not precisely known, neither is the local temperature rise following exposure. The ICNIRP guidelines define reference levels for magnetic field exposure for the general public that contain large safety factors – for medical diagnostics, they might be exceeded for a short time. In this article, research and guidelines in this field are briefly reviewed, and new results are presented in order to contribute to a future definition of safety limits for oscillating magnetic fields in MPI.

[1]  O. Doessel,et al.  Patient‐individual local SAR determination: In vivo measurements and numerical validation , 2012, Magnetic resonance in medicine.

[2]  O. Dössel,et al.  Experimental thresholds of magnetically induced currents via a figure-of-eight coil up to 25 kHz , 2012, Biomedizinische Technik. Biomedical engineering.

[3]  O. Dössel,et al.  Toward individualized SAR models and in vivo validation , 2011, Magnetic resonance in medicine.

[4]  Olaf Dössel,et al.  CALCULATION AND EVALUATION OF CURRENT DENSITIES AND THERMAL HEATING IN THE BODY DURING MPI , 2010 .

[5]  A. Jordan,et al.  Clinical applications of magnetic nanoparticles for hyperthermia , 2008, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[6]  James C. Lin DOSIMETRIC COMPARISON BETWEEN DIFFERENT QUANTITIES FOR LIMITING EXPOSURE IN THE RF BAND: RATIONALE AND IMPLICATIONS FOR GUIDELINES , 2007, Health physics.

[7]  Bernhard Gleich,et al.  Tomographic imaging using the nonlinear response of magnetic particles , 2005, Nature.

[8]  K. Uğurbil,et al.  Temperature and SAR calculations for a human head within volume and surface coils at 64 and 300 MHz , 2004, Journal of magnetic resonance imaging : JMRI.

[9]  J D Bourland,et al.  Review of Patient Safety in Time‐Varying Gradient Fields , 2000, Journal of magnetic resonance imaging : JMRI.

[10]  R. W. Lau,et al.  Electromagnetic and thermal modeling of SAR and temperature fields in tissue due to an RF decoupling coil , 1999, Magnetic resonance in medicine.

[11]  O. Gandhi,et al.  Specific absorption rates and induced current densities for an anatomy‐based model of the human for exposure to time‐varying magnetic fields of MRI , 1999, Magnetic resonance in medicine.

[12]  R. W. Lau,et al.  The dielectric properties of biological tissues: III. Parametric models for the dielectric spectrum of tissues. , 1996, Physics in medicine and biology.

[13]  W Irnich,et al.  Magnetostimulation in MRI , 1995, Magnetic resonance in medicine.

[14]  J. P. Reilly,et al.  Magnetic field excitation of peripheral nerves and the heart: a comparison of thresholds , 1991, Medical and Biological Engineering and Computing.

[15]  J. Patrick Reilly,et al.  Electrical Stimulation and Electropathology , 1991 .

[16]  J. Reilly Peripheral nerve stimulation by induced electric currents: Exposure to time-varying magnetic fields , 1989, Medical and Biological Engineering and Computing.

[17]  Emine Ulku Saritas,et al.  Safety Limits for Human-Size Magnetic Particle Imaging Systems , 2012 .

[18]  O. Dössel,et al.  Simulations of Temperature Increase Due to Time Varying Magnetic Fields Up to 100 kHz , 2011 .

[19]  Olaf Dössel,et al.  Optimizing Coil Currents for reduced SAR in Magnetic Particle Imaging , 2009 .

[20]  H. H. Penns Analysis of tissue and arterial blood temperatures in the resting human forearm , 1948 .