Evaluation of Voltage Sag Ride-Through of a Doubly Fed Induction Generator Wind Turbine with Series Grid Side Converter

With steadily increasing wind turbine penetration, regulatory standards for grid interconnection have evolved to require that wind generation systems ride- through disturbances such as faults and support the grid during such events. Conventional ride-through accommodations result in high currents and torque or are unable to ride-through down to zero volts. This paper explores two DFIG configurations in which a series grid side converter (SGSC) is employed exclusively for voltage sag ride-through. A control strategy applicable to both configurations is developed whereby the SGSC engages to stabilize the stator flux at the beginning and resolution of the sag event. Simulation results show excellent zero voltage ride-through response.

[1]  I.D. Navarro,et al.  Control of doubly-fed induction generators under asymmetrical grid conditions , 2007, 2007 European Conference on Power Electronics and Applications.

[2]  Math Bollen,et al.  Voltage dips at the terminals of wind power installations , 2005 .

[3]  V. Blasko,et al.  Operation of a phase locked loop system under distorted utility conditions , 1997 .

[4]  Lie Xu,et al.  Dynamic Modeling and Control of DFIG-Based Wind Turbines Under Unbalanced Network Conditions , 2007, IEEE Transactions on Power Systems.

[5]  Li Ran,et al.  Control of a doubly fed induction generator in a wind turbine during grid fault ride-through , 2006, IEEE Transactions on Energy Conversion.

[6]  F. Briz,et al.  Analysis and design of current regulators using complex vectors , 1997, IAS '97. Conference Record of the 1997 IEEE Industry Applications Conference Thirty-Second IAS Annual Meeting.

[7]  Bingsen Wang,et al.  Operation and control of a dynamic voltage restorer using transformer coupled H-bridge converters , 2006, IEEE Transactions on Power Electronics.

[8]  Math Bollen,et al.  Understanding Power Quality Problems , 1999 .

[9]  R.W. De Doncker,et al.  Adjustable speed generators for wind turbines based on doubly-fed induction machines and 4-quadrant IGBT converters linked to the rotor , 2000, Conference Record of the 2000 IEEE Industry Applications Conference. Thirty-Fifth IAS Annual Meeting and World Conference on Industrial Applications of Electrical Energy (Cat. No.00CH37129).

[10]  J. Niiranen,et al.  Ride-Through Analysis of Doubly Fed Induction Wind-Power Generator Under Unsymmetrical Network Disturbance , 2006, IEEE Transactions on Power Systems.

[11]  G. Venkataramanan,et al.  A Fault Tolerant Doubly Fed Induction Generator Wind Turbine Using a Parallel Grid Side Rectifier and Series Grid Side Converter , 2008, IEEE Transactions on Power Electronics.

[12]  Mike Barnes,et al.  Mitigation of saturation in dynamic voltage restorer connection transformers , 2002 .

[13]  A. Dittrich,et al.  Comparison of fault ride-through strategies for wind turbines with DFIM generators , 2005, 2005 European Conference on Power Electronics and Applications.

[14]  Janaka Ekanayake,et al.  Dynamic modeling of doubly fed induction generator wind turbines , 2003 .

[15]  J. López,et al.  Wind Turbines Based on Doubly Fed Induction Generator Under Asymmetrical Voltage Dips , 2008, IEEE Transactions on Energy Conversion.

[16]  Siegfried Heier,et al.  Grid Integration of Wind Energy Conversion Systems , 1998 .

[17]  G. Venkataramanan,et al.  A Unified Architecture for Doubly Fed Induction Generator Wind Turbines using a Parallel Grid Side Rectifier and Series Grid Side Converter , 2007, 2007 Power Conversion Conference - Nagoya.

[18]  A. Petersson Analysis, Modeling and Control of Doubly-Fed Induction Generators for Wind Turbines , 2005 .

[19]  Thomas Ackermann,et al.  International comparison of requirements for connection of wind turbines to power systems , 2005 .

[20]  P. Sanchis,et al.  Dynamic Behavior of the Doubly Fed Induction Generator During Three-Phase Voltage Dips , 2007, IEEE Transactions on Energy Conversion.

[21]  David J. Atkinson,et al.  Stator-flux-oriented control of a doubly-fed induction machine with and without position encoder , 2000 .

[22]  G.R. Slemon,et al.  Modelling of inductance machines for electric drives , 1988, Conference Record of the 1988 IEEE Industry Applications Society Annual Meeting.

[23]  Hadi Saadat,et al.  Power System Analysis , 1998 .

[24]  I. Erlich,et al.  Dynamic Behavior of DFIG-Based Wind Turbines during Grid Faults , 2007, 2007 Power Conversion Conference - Nagoya.

[25]  N. Mohan,et al.  Control of a Doubly Fed Induction Wind Generator Under Unbalanced Grid Voltage Conditions , 2007, IEEE Transactions on Energy Conversion.

[26]  J. Morren,et al.  Ridethrough of wind turbines with doubly-fed induction generator during a voltage dip , 2005, IEEE Transactions on Energy Conversion.

[27]  Jeong-Ik Jang,et al.  Control of Back-to-Back PWM Converters for DFIG Wind Turbine Systems under Unbalanced Grid Voltage , 2007, 2007 IEEE International Symposium on Industrial Electronics.