Open micro-fluidic system for atomic force microscopy-guided in situ electrochemical probing of a single cell.

Ultra-sharp nano-probes and customized atomic force microscopy (AFM) have previously been developed in our laboratory for in situ sub-cellular probing of electrochemical phenomena in living plant cells during their photosynthesis. However, this AFM-based electrochemical probing still has numerous engineering challenges such as immobilization of the live cells, compatibility of the immobilization procedure with AFM manipulation of the probe, maintenance of biological activity of the cells for an extended time while performing the measurements, and minimization of electrochemical noise. Thus, we have developed an open micro-fluidic channel system (OMFC) in which individual cells can be immobilized in micro-traps by capillary flow. This system affords easy AFM access and allows for maintenance of the cells in a well-defined chemical environment, which sustains their biological activity. The use of micro-channels for making the electrochemical measurements significantly reduces parasitic electrical capacitances and allows for current detection in the sub-pico-ampere range at high signal bandwidths. The OMFC was further studied using simulation packages for optimal design conditions. This system was successfully used to measure light-dependent oxidation currents of a few pico-amperes from the green alga Chlamydomonas reinhardtii.

[1]  Aaron R Wheeler,et al.  Microfluidic device for single-cell analysis. , 2003, Analytical chemistry.

[2]  Luke P. Lee,et al.  A single cell electroporation chip. , 2005, Lab on a chip.

[3]  C. Vílchez,et al.  Studies on the suitability of alginate-entrapped Chlamydomonas reinhardtii cells for sustaining nitrate consumption processes. , 2001, Bioresource technology.

[4]  David R Walt,et al.  Optical imaging fiber-based single live cell arrays: a high-density cell assay platform. , 2002, Analytical chemistry.

[5]  A. Bulychev,et al.  Micro-electrode Measurements of the Transmembrane Potential of Chloroplasts and its Photoinduced Changes , 1972, Nature.

[6]  K Bergman,et al.  Characterization of photodamage to Escherichia coli in optical traps. , 1999, Biophysical journal.

[7]  Luke P. Lee,et al.  Microfluidic application-specific integrated device for monitoring direct cell-cell communication via gap junctions between individual cell pairs , 2005 .

[8]  I. Ridge,et al.  Mechanisms of photosynthesis , 1981 .

[9]  Luke P. Lee,et al.  Open-access microfluidic patch-clamp array with raised lateral cell trapping sites. , 2006, Lab on a chip.

[10]  W. Boireau,et al.  Kinetics of redox conversion at a gold electrode of water-insoluble ubiquinone (UQ(10)) and plastoquinone (PQ(9)) incorporated in supported phospholipid layers , 1998 .

[11]  Robert Eugene Blankenship Molecular mechanisms of photosynthesis , 2002 .

[12]  Richard A. Flynn,et al.  Parallel transport of biological cells using individually addressable VCSEL arrays as optical tweezers , 2002 .

[13]  Petra Fromme,et al.  Three-dimensional structure of cyanobacterial photosystem I at 2.5 Å resolution , 2001, Nature.

[14]  W. Donachie,et al.  Growth of the Bacterial Cell , 1970, Nature.

[15]  Mehmet Toner,et al.  A microfabrication-based dynamic array cytometer. , 2002, Analytical chemistry.

[16]  J. Shapiro,et al.  Escherichia coli K-12 cell-cell interactions seen by time-lapse video , 1989, Journal of bacteriology.

[17]  F. Prinz,et al.  Nanoscale probe system for cell-organelle analysis , 2008 .

[18]  C. Rotsch,et al.  Dimensional and mechanical dynamics of active and stable edges in motile fibroblasts investigated by using atomic force microscopy. , 1999, Proceedings of the National Academy of Sciences of the United States of America.

[19]  A. Bulychev,et al.  Patch-clamp studies of light-induced currents across the thylakoid membrane of isolated chloroplasts , 1992 .

[20]  W F Heinz,et al.  Relative microelastic mapping of living cells by atomic force microscopy. , 1998, Biophysical journal.

[21]  Assaf Deutsch,et al.  A novel miniature cell retainer for correlative high-content analysis of individual untethered non-adherent cells. , 2006, Lab on a chip.

[22]  Shoji Takeuchi,et al.  A trap-and-release integrated microfluidic system for dynamic microarray applications , 2007, Proceedings of the National Academy of Sciences.

[23]  Luke P. Lee,et al.  Soft-state biomicrofluidic pulse generator for single cell analysis , 2006 .

[24]  Zhao-Lun Fang,et al.  Integration of single cell injection, cell lysis, separation and detection of intracellular constituents on a microfluidic chip. , 2004, Lab on a chip.

[25]  E. Delamarche,et al.  Microfluidic Networks Made of Poly(dimethylsiloxane), Si, and Au Coated with Polyethylene Glycol for Patterning Proteins onto Surfaces , 2001 .

[26]  M. Deutsch,et al.  Apparatus for high-precision repetitive sequential optical measurement of living cells. , 1994, Cytometry.

[27]  E. H. Harris The Chlamydomonas sourcebook , 2009 .

[28]  François O. Laforge,et al.  Nanoelectrochemistry of mammalian cells , 2008, Proceedings of the National Academy of Sciences.

[29]  Fritz B. Prinz,et al.  Cantilever tip probe arrays for simultaneous SECM and AFM analysis , 2005 .

[30]  Luke P. Lee,et al.  Dynamic single cell culture array. , 2006, Lab on a chip.

[31]  F. Prinz,et al.  Microfabrication Technology of Biodegradable Polymers for Interconnecting Microstructures , 2006, Journal of Microelectromechanical Systems.

[32]  George M. Whitesides,et al.  Selective Deposition of Proteins and Cells in Arrays of Microwells , 2001 .

[33]  Ute Drechsler,et al.  Autonomous microfluidic capillary system. , 2002, Analytical chemistry.