Centre of pressure displacements in trans-femoral amputees during gait.

The aim of this study was to describe and quantify centre of pressure (CoP) displacement during walking in 12 unilateral trans-femoral amputees who had worn a prosthesis for at least 10 years. All subjects wore the same type of prosthesis and seven healthy subjects acted as controls. The CoP was acquired by an F-scan system and the displacements along the longitudinal axis of the foot versus time were quantified. An asymmetry of both temporal and spatial parameters of CoP patterns occurred between the sound and the prosthetic foot. The double support time and the time during which the CoP remained in the heel and mid-foot region were longer for the prosthetic limb. Conversely, the stance phase was longer for the sound limb, as was the time spent by the CoP in the forefoot. There was a redistribution of the time during which the CoP remained within the different zones of the sound foot with respect to the normal feet of the control subjects. The asymmetry seen in trans-femoral amputee stance is due not only to an abnormal spatio-temporal distribution of the CoP under the prosthetic leg, but also to a modification of the spatio-temporal distribution of the CoP under the sound foot compared to the normal foot. We conclude that an adaptation occurs in the control of the stance phase on the sound side during amputee gait.

[1]  W D Spence,et al.  A methodology for studying the effects of various types of prosthetic feet on the biomechanics of trans-femoral amputee gait. , 1999, Journal of biomechanics.

[2]  J. Czerniecki,et al.  Mechanical work adaptations of above-knee amputee ambulation. , 1996, Archives of physical medicine and rehabilitation.

[3]  A. Lees,et al.  Adjustments in gait symmetry with walking speed in trans-femoral and trans-tibial amputees. , 2003, Gait & posture.

[4]  H S Ranu,et al.  An evaluation of the centre of pressure for successive steps with miniature triaxial load cells. , 1988, Journal of medical engineering & technology.

[5]  D. Winter A.B.C. (anatomy, biomechanics and control) of balance during standing and walking , 1995 .

[6]  E. Isakov,et al.  Transtibial amputee gait: Timedistance parameters and EMG activity , 2000, Prosthetics and orthotics international.

[7]  H. J. de Jongh,et al.  Prosthetic gait of unilateral transfemoral amputees: a kinematic study. , 1995, Archives of physical medicine and rehabilitation.

[8]  J. Czerniecki,et al.  Rehabilitation in limb deficiency. 1. Gait and motion analysis. , 1996, Archives of physical medicine and rehabilitation.

[9]  A H Hansen,et al.  Prosthetic foot rollover shapes with implications for alignment of transtibial prostheses , 2000, Prosthetics and orthotics international.

[10]  C Marincek,et al.  Double-limb support and step-length asymmetry in below-knee amputees. , 1997, Scandinavian journal of rehabilitation medicine.

[11]  J. Engsberg,et al.  Normative ground reaction force data for able-bodied and below-knee-amputee children during walking. , 1993, Journal of pediatric orthopedics.

[12]  J Mizrahi,et al.  Some gait characteristics of below-knee amputees and their reflection on the ground reaction forces. , 1986, Engineering in medicine.

[13]  Murray Mp,et al.  Gait patterns in above-knee amputee patients: hydraulic swing control vs constant-friction knee components. , 1983 .

[14]  K Oberg,et al.  Prosthetic gait pattern in unilateral above-knee amputees. , 1973, Scandinavian journal of rehabilitation medicine.

[15]  Skinner Hb,et al.  Gait analysis in amputees. , 1985 .

[16]  Ground reaction forces and center of pressure patterns in the gait of children with amputation: preliminary report. , 1985, Archives of physical medicine and rehabilitation.

[17]  C. Ekdahl,et al.  Gait in male trans-tibial amputees: A comparative study with healthy subjects in relation to walking speed , 1994, Prosthetics and orthotics international.

[18]  J S Arora,et al.  Accelerographic, temporal, and distance gait factors in below-knee amputees. , 1977, Physical therapy.

[19]  J Perry,et al.  Below-knee amputee gait with dynamic elastic response prosthetic feet: a pilot study. , 1990, Journal of rehabilitation research and development.

[20]  A M Boonstra,et al.  The gait of unilateral transfemoral amputees. , 1994, Scandinavian journal of rehabilitation medicine.

[21]  A L Hof,et al.  Gait analysis of transfemoral amputee patients using prostheses with two different knee joints. , 1996, Archives of physical medicine and rehabilitation.

[22]  E. N. Zuniga,et al.  Gait patterns in above-knee amputees. , 1972, Archives of physical medicine and rehabilitation.

[23]  J. S. Rietman,et al.  Gait analysis in prosthetics: Opinions, ideas and conclusions , 2002, Prosthetics and orthotics international.

[24]  S. Rithalia,et al.  The biomechanical effects of the inclusion of a torque absorber on trans-femoral amputee gait, a pilot study , 2002, Prosthetics and orthotics international.

[25]  Gait Patterns of Transtibial Amputee Patients Walking Indoors Barefoot , 2003, American journal of physical medicine & rehabilitation.

[26]  M. Pierrynowski,et al.  The role of the contralateral limb in below-knee amputee gait , 1990, Prosthetics and orthotics international.

[27]  A. Lees,et al.  The functional demands on the intact limb during walking for active transfemoral and transtibial amputees , 2000, Prosthetics and orthotics international.