Frictional heating of total hip implants. Part 1: measurements in patients.

Hip implants heat up due to friction during long lasting, high loading activities like walking. Thermal damage in the surrounding soft and hard tissues and deteriorated lubrication of synovial fluid could contribute to implant loosening. The goal of this study was to determine the implant temperatures in vivo under varying conditions. Temperatures and contact forces in the joints were measured in seven joints of five patients using instrumented prostheses with alumina ceramic heads and telemetry data transmission. The peak temperature in implants with polyethylene cups rose up to 43.1 degrees C after an hour of walking but varied considerably individually. Even higher temperatures at the joints are probable for patients with higher body weight or while jogging. The peak temperature was lower with a ceramic cup, showing the influence of friction in the joint. During cycling the peak temperatures were lower than during walking, proving the effect of force magnitudes on the produced heat. However, no positive correlation was found between force magnitude and maximum temperature during walking. Other individual parameters than just the joint force influence the implant temperatures. Based on the obtained data and the available literature about thermal damage of biological tissues a detrimental effect of friction induced heat on the stability of hip implants cannot be excluded. Because the potential risk for an individual patient cannot be foreseen, the use and improvement of low friction implant materials is important.

[1]  D. Resnick,et al.  Hip joint fluid: detection and distribution at MR imaging and US with cadaveric correlation. , 1998, Radiology.

[2]  V O Saikko,et al.  A Three-Axis Hip Joint Simulator for Wear and Friction Studies on Total Hip Prostheses , 1996, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[3]  A Rohlmann,et al.  Hip endoprosthesis for in vivo measurement of joint force and temperature. , 1999, Journal of biomechanics.

[4]  H. Mckellop,et al.  Frictional heating of bearing materials tested in a hip joint wear simulator , 1997, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[5]  A. Wilson,et al.  The effect of exercise-induced localised hyperthermia on tendon cell survival. , 1997, The Journal of experimental biology.

[6]  S. Biyikli,et al.  Measurements of thermal properties for human femora. , 1986, Journal of biomedical materials research.

[7]  O. Hudlická Growth of capillaries in skeletal and cardiac muscle. , 1982, Circulation research.

[8]  H. Bertram,et al.  Osteolysis in alloarthroplasty of the hip. The role of ultra-high molecular weight polyethylene wear particles. , 1990, Clinical orthopaedics and related research.

[9]  Boundary lubricating property of synovial fluid on artificial material and lubrication of artificial joints. , 1983, Nihon Seikeigeka Gakkai zasshi.

[10]  S. Orlov,et al.  Protection against necrosis but not apoptosis by heat-stress proteins in vascular smooth muscle cells: evidence for distinct modes of cell death. , 1999, Hypertension.

[11]  H. Mckellop,et al.  Potential thermal artifacts in hip joint wear simulators. , 1999, Journal of biomedical materials research.

[12]  L. Bourget,et al.  Changes in heat shock protein synthesis and heat sensitivity during mouse thymocyte development. , 1993, Developmental genetics.

[13]  J. Goodship,et al.  Developmental genetics of the heart. , 1996, Current opinion in genetics & development.

[14]  A Rohlmann,et al.  Influence of shoes and heel strike on the loading of the hip joint. , 1995, Journal of biomechanics.

[15]  P. Pontiggia,et al.  Therapeutic hyperthermia in cancer and AIDS: an updated survey. , 1996, Journal of environmental pathology, toxicology and oncology : official organ of the International Society for Environmental Toxicology and Cancer.

[16]  J P Paul,et al.  Heat transfer analysis of frictional heat dissipation during articulation of femoral implants. , 1988, Journal of biomedical materials research.

[17]  Jorge A. Ochoa,et al.  “In vivo” determination of normal, constrained and unconstrained tha kinematics , 1998 .

[18]  P. Brodal,et al.  Capillary supply of skeletal muscle fibers in untrained and endurance-trained men. , 1977, The American journal of physiology.

[19]  A Rohlmann,et al.  Multichannel strain gauge telemetry for orthopaedic implants. , 1988, Journal of biomechanics.

[20]  R Huiskes,et al.  Some fundamental aspects of human joint replacement. Analyses of stresses and heat conduction in bone-prosthesis structures. , 1980, Acta orthopaedica Scandinavica. Supplementum.

[21]  S. Weinbaum,et al.  A new simplified bioheat equation for the effect of blood flow on local average tissue temperature. , 1985, Journal of biomechanical engineering.

[22]  D. Dowson,et al.  The effect of sliding velocity on the friction and wear of UHMWPE for use in total artificial joints , 1994 .

[23]  A Simkin,et al.  Effect of Moderate Bone Hyperthermia on Cell Viability and Mechanical Function , 1998, Clinical orthopaedics and related research.

[24]  G. Bergmann,et al.  Hip joint loading during walking and running, measured in two patients. , 1993, Journal of biomechanics.

[25]  C. Winterford,et al.  The role of apoptosis in the response of cells and tumours to mild hyperthermia. , 1991, International journal of radiation biology.

[26]  J. Davidson,et al.  Wear, creep, and frictional heating of femoral implant articulating surfaces and the effect on long-term performance--Part II, Friction, heating, and torque. , 1988, Journal of biomedical materials research.