The design of and chronic tissue response to a composite nerve electrode with patterned stiffness

OBJECTIVE As neural interfaces demonstrate success in chronic applications, a novel class of reshaping electrodes with patterned regions of stiffness will enable application to a widening range of anatomical locations. Patterning stiff regions and flexible regions of the electrode enables nerve reshaping while accommodating anatomical constraints of various implant locations ranging from peripheral nerves to spinal and autonomic plexi. APPROACH Introduced is a new composite electrode enabling patterning of regions of various electrode mechanical properties. The initial demonstration of the composite's capability is the composite flat interface nerve electrode (C-FINE). The C-FINE is constructed from a sandwich of patterned PEEK within layers of pliable silicone. The shape of the PEEK provides a desired pattern of stiffness: stiff across the width of the nerve to reshape the nerve, but flexible along its length to allow for bending with the nerve. This is particularly important in anatomical locations near joints or organs, and in constrained compartments. We tested pressure and volume design constraints in vitro to verify that the C-FINE can attain a safe cuff-to-nerve ratio (CNR) without impeding intraneural blood flow. We measured nerve function as well as nerve and axonal morphology following 3 month implantation of the C-FINE without wires on feline peripheral nerves in anatomically constrained areas near mobile joints and major blood vessels in both the hind and fore limbs. MAIN RESULTS In vitro inflation tests showed effective CNRs (1.93  ±  0.06) that exceeded the industry safety standard of 1.5 at an internal pressure of 20 mmHg. This is less than the 30 mmHg shown to induce loss of conduction or compromise blood flow. Implanted cats showed no changes in physiology or electrophysiology. Behavioral signs were normal suggesting healthy nerves. Motor nerve conduction velocity and compound motor action potential did not change significantly between implant and explant (p  >  0.15 for all measures). Axonal density and myelin sheath thickness was not significantly different within the electrode compared to sections greater than 2 cm proximal to implanted cuffs (p  >  0.14 for all measures). SIGNIFICANCE We present the design and verification of a novel nerve cuff electrode, the C-FINE. Laminar manufacturing processes allow C-FINE stiffness to be configured for specific applications. Here, the central region in the configuration tested is stiff to reshape or conform to the target nerve, while edges are highly flexible to bend along its length. The C-FINE occupies less volume than other NCEs, making it suitable for implantation in highly mobile locations near joints. Design constraints during simulated transient swelling were verified in vitro. Maintenance of nerve health in various challenging anatomical locations (sciatic and median/ulnar nerves) was verified in a chronic feline model in vivo.

[1]  G Lundborg,et al.  Effects of graded compression on intraneural blood blow. An in vivo study on rabbit tibial nerve. , 1981, The Journal of hand surgery.

[2]  A. Nitz,et al.  Pneumatic tourniquet application and nerve integrity: Motor function and electrophysiology , 1986, Experimental Neurology.

[3]  Ronald J Triolo,et al.  Fascicular anatomy of human femoral nerve: implications for neural prostheses using nerve cuff electrodes. , 2009, Journal of rehabilitation research and development.

[4]  G. Murrell,et al.  Brachial Plexus Injuries During Shoulder Arthroplasty: What Causes Them and How to Prevent Them , 2014 .

[5]  Holland Gr The effect of buffer molarity on the size, shape and sheath thickness of peripheral myelinated nerve fibres. , 1982 .

[7]  Dustin J. Tyler,et al.  Stability and selectivity of a chronic, multi-contact cuff electrode for sensory stimulation in human amputees , 2013, 2013 6th International IEEE/EMBS Conference on Neural Engineering (NER).

[8]  L. Dahlin,et al.  Aspects on pathophysiology of nerve entrapments and nerve compression injuries. , 1991, Neurosurgery clinics of North America.

[9]  W. Sufan,et al.  Sciatic nerve regeneration through alginate with tubulation or nontubulation repair in cat. , 2001, Journal of neurotrauma.

[10]  Michael E. Miller,et al.  Standing After Spinal Cord Injury With Four-Contact Nerve-Cuff Electrodes for Quadriceps Stimulation , 2008, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[11]  S. Ho,et al.  Motor nerve conduction parameters in the cat , 1989 .

[12]  E. Valderrama,et al.  Polyimide cuff electrodes for peripheral nerve stimulation , 2000, Journal of Neuroscience Methods.

[13]  D. S. Bright,et al.  Long-term pain control by direct peripheral-nerve stimulation. , 1982, The Journal of bone and joint surgery. American volume.

[14]  K. Fields,et al.  Peripheral nerve entrapment and injury in the upper extremity. , 2010, American family physician.

[15]  Niloy Bhadra,et al.  High frequency electrical conduction block of the pudendal nerve , 2006, Journal of neural engineering.

[16]  D. Durand,et al.  Functionally selective peripheral nerve stimulation with a flat interface nerve electrode , 2002, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[17]  J. Stewart,et al.  Peripheral nerve fascicles: Anatomy and clinical relevance , 2003, Muscle & nerve.

[18]  A R Hargens,et al.  The carpal tunnel syndrome. A study of carpal canal pressures. , 1981, The Journal of bone and joint surgery. American volume.

[19]  J T Mortimer,et al.  Neural and connective tissue response to long-term implantation of multiple contact nerve cuff electrodes. , 2000, Journal of biomedical materials research.

[20]  R. Triolo,et al.  Selective activation of the human tibial and common peroneal nerves with a flat interface nerve electrode , 2013, Journal of neural engineering.

[21]  C. Hildebrand,et al.  Relation between myelin sheath thickness and axon size in spinal cord white matter of some vertebrate species , 1978, Journal of the Neurological Sciences.

[22]  Hopper Cl,et al.  Bilateral femoral neuropathy complicating vaginal hysterectomy. Analysis of contributing factors in 3 patients. , 1968 .

[23]  Hayes Gj,et al.  Experimental improvements in the use of Silastic cuff for peripheral nerve repair. , 1968 .

[24]  D. Durand,et al.  Chronic Response of the Rat Sciatic Nerve to the Flat Interface Nerve Electrode , 2003, Annals of Biomedical Engineering.

[25]  Curtis Wells Dewey A Practical Guide to Canine and Feline Neurology , 2003 .

[26]  M. Keith,et al.  Stimulation Stability and Selectivity of Chronically Implanted Multicontact Nerve Cuff Electrodes in the Human Upper Extremity , 2009, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[27]  G. E. Loeb,et al.  Cuff electrodes for chronic stimulation and recording of peripheral nerve activity , 1996, Journal of Neuroscience Methods.

[28]  A. Filler Diagnosis and treatment of pudendal nerve entrapment syndrome subtypes: imaging, injections, and minimal access surgery. , 2009, Neurosurgical focus.

[29]  A. Spurr A low-viscosity epoxy resin embedding medium for electron microscopy. , 1969, Journal of ultrastructure research.

[30]  R. Triolo,et al.  Selective stimulation of the human femoral nerve with a flat interface nerve electrode , 2010, Journal of neural engineering.

[31]  A. Tomek,et al.  Iatrogenic sciatic nerve injury in eighteen dogs and nine cats (1997-2006). , 2007, Veterinary surgery : VS.

[32]  M. Greenman Studies on the regeneration of the peroneal nerve of the albino rat: Number and sectional areas of fibers: Area relation of axis to sheath , 1913 .

[33]  J. Gómez-Hoyos,et al.  Deep gluteal syndrome , 2015, Journal of hip preservation surgery.

[34]  Dominique M Durand,et al.  Fabrication of High Contact-Density, Flat-Interface Nerve Electrodes for Recording and Stimulation Applications. , 2016, Journal of visualized experiments : JoVE.

[35]  M. Stringer,et al.  Iatrogenic upper limb nerve injuries: a systematic review , 2011, ANZ journal of surgery.

[36]  R. Kobetic,et al.  Walking after incomplete spinal cord injury using an implanted FES system: a case report. , 2007, Journal of rehabilitation research and development.

[37]  Daniel K. Leventhal,et al.  Chronic histological effects of the flat interface nerve electrode , 2006, Journal of neural engineering.

[38]  M. Baba,et al.  Changes in peripheral nerve fibres distal to a constriction , 1982, Journal of the Neurological Sciences.

[39]  M. Keith,et al.  Human Nerve Stimulation Thresholds and Selectivity Using a Multi-contact Nerve Cuff Electrode , 2007, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[40]  S. Rossignol,et al.  Electroneurographic recordings with polymer cuff electrodes in paralyzed cats , 1982, Journal of Neuroscience Methods.

[41]  Z. Rosenberg,et al.  MR imaging of entrapment neuropathies of the lower extremity. Part 2. The knee, leg, ankle, and foot. , 2010, Radiographics : a review publication of the Radiological Society of North America, Inc.

[42]  N. Brill Optimization of High Density Nerve Cuff Stimulation in Upper Extremity Nerves , 2015 .

[43]  R. Gelberman,et al.  Peripheral nerve compression , 1993 .

[44]  C. A. Zorman,et al.  Diamond-on-Polymer Microelectrode Arrays Fabricated Using a Chemical Release Transfer Process , 2011, Journal of Microelectromechanical Systems.

[45]  R J Triolo,et al.  Chronic stability and selectivity of four-contact spiral nerve-cuff electrodes in stimulating the human femoral nerve , 2009, Journal of neural engineering.

[46]  Narendra Bhadra,et al.  Bladder voiding by combined high frequency electrical pudendal nerve block and sacral root stimulation , 2008, Neurourology and urodynamics.

[47]  G. Yarkony,et al.  Standing the spinal cord injured patient by electrical stimulation: refinement of a protocol for clinical use , 1989, IEEE Transactions on Biomedical Engineering.

[48]  G. Loeb,et al.  Conduction studies in peripheral cat nerve using implanted electrodes: II. The effects of prolonged constriction on regeneration of crushed nerve fibers , 1988, Muscle & nerve.

[49]  C. Ethier,et al.  Nerve cuff stimulation and the effect of fascicular organization for hand grasp in nonhuman primates , 2009, 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[50]  R J Triolo,et al.  Intraoperative evaluation of the spiral nerve cuff electrode on the femoral nerve trunk , 2009, Journal of neural engineering.

[51]  R. Basinger,et al.  Osteofascial compartment syndrome in the dog. , 1987, Veterinary surgery : VS.

[52]  Ilya Kolb,et al.  Laryngeal elevation by selective stimulation of the hypoglossal nerve. , 2013, Journal of neural engineering.

[53]  Z. Rosenberg,et al.  MR imaging of entrapment neuropathies of the lower extremity. Part 1. The pelvis and hip. , 2010, Radiographics : a review publication of the Radiological Society of North America, Inc.

[54]  J. Mortimer,et al.  A spiral nerve cuff electrode for peripheral nerve stimulation , 1988, IEEE Transactions on Biomedical Engineering.

[55]  C. Suschek,et al.  Aspects of static and dynamic motor function in peripheral nerve regeneration: SSI and CatWalk gait analysis , 2011, Behavioural Brain Research.

[56]  S. Ho,et al.  A new method for recording and analysing evoked motor potentials from dogs , 1989 .

[57]  E. Marsolais,et al.  Functional walking in paralyzed patients by means of electrical stimulation. , 1983, Clinical orthopaedics and related research.

[58]  Ö. Aksoy,et al.  Comparison of fixation methods for peripheral nerve fiber. , 2013 .

[59]  Powell Hc,et al.  Pathology of experimental nerve compression. , 1986 .

[60]  R. Triolo,et al.  Performance of epimysial stimulating electrodes in the lower extremities of individuals with spinal cord injury , 2004, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[61]  C. Zorman,et al.  Development of a Microfabricated Flat Interface Nerve Electrode Based on Liquid Crystal Polymer and Polynorbornene Multilayered Structures , 2007, 2007 3rd International IEEE/EMBS Conference on Neural Engineering.

[62]  K. Kilgore,et al.  Reversible Nerve Conduction Block Using Kilohertz Frequency Alternating Current , 2014, Neuromodulation : journal of the International Neuromodulation Society.

[63]  T. Ponsky,et al.  Suture choice matters in rabbit model of laparoscopic, preperitoneal, inguinal hernia repair. , 2014, Journal of laparoendoscopic & advanced surgical techniques. Part A.

[64]  S. Hunter,et al.  Pain suppression by peripheral nerve stimulation. Chronic effects of implanted devices. , 1977, Applied neurophysiology.

[65]  M. Barber,et al.  Pelvic nerve injury following gynecologic surgery: a prospective cohort study. , 2009, American journal of obstetrics and gynecology.

[66]  B. Parratte,et al.  Anatomical bases of superior gluteal nerve entrapment syndrome in the suprapiriformis foramen , 2002, Surgical and Radiologic Anatomy.

[67]  Benoit P. Delhaye,et al.  The neural basis of perceived intensity in natural and artificial touch , 2016, Science Translational Medicine.

[68]  J. Michael Schro¨der,et al.  Altered ratio between axon diameter and myelin sheath thickness in regenerated nerve fibers. , 1972 .

[69]  M. Stringer,et al.  Iatrogenic femoral nerve injury: a systematic review , 2011, Surgical and Radiologic Anatomy.

[70]  Ronald J Triolo,et al.  Optimization of selective stimulation parameters for multi-contact electrodes , 2013, Journal of NeuroEngineering and Rehabilitation.

[71]  M. Keith,et al.  A neural interface provides long-term stable natural touch perception , 2014, Science Translational Medicine.

[72]  G. P. Braz,et al.  Functional Electrical Stimulation Control of Standing and Stepping After Spinal Cord Injury: A Review of Technical Characteristics , 2009, Neuromodulation : journal of the International Neuromodulation Society.

[73]  E. Marsolais,et al.  Development of a practical electrical stimulation system for restoring gait in the paralyzed patient. , 1988, Clinical orthopaedics and related research.

[74]  E. Marsolais,et al.  Implanted Functional Neuromuscular Stimulation systems for individuals with cervical spinal cord injuries: clinical case reports. , 1996, Archives of physical medicine and rehabilitation.

[75]  Sheeba Joseph,et al.  Human distal sciatic nerve fascicular anatomy: implications for ankle control using nerve-cuff electrodes. , 2012, Journal of rehabilitation research and development.

[76]  M. Maltenfort,et al.  Vulnerability of the Femoral Nerve During Complex Anterior and Posterior Spinal Surgery , 2009, The journal of spinal cord medicine.

[77]  Yasunobu Handa,et al.  Review: Clinical benefits of functional electrical stimulation cycling exercise for subjects with central neurological impairments , 2011 .