The accuracy of two different extra-medullary tibial cutting guides for posterior tibial slope in total knee arthroplasty.

OBJECTIVES This study aims to evaluate the effectiveness of two different external tibial cutting guides with and without a spike anchoring to the intercondylar eminentia to achieve a desired posterior tibial slope. PATIENTS AND METHODS Between January 2008 and December 2011, 120 posterior cruciate ligament protecting total knee arthroplasty (TKA) surgeries of 83 patients in which two different external tibial cutting guides used were included. Fifty-nine knees were included into the spiked and 61 knees were included into the spikeless cutting guide group. Posterior tibial slope angles were measured using the postoperative X-rays. RESULTS There was no significant difference between two groups in terms of age, sex, and body mass indexes (p<0.05). While the mean postoperative slope angle was 2.66°±2.001°(range 0°-7°) in spiked group, it was 2.46°±2.277° (range 0°-7°) in spikeless group. Both systems had identical accuracy, indicating a low rate. The comparison of variances of two groups showed that both cutting guides had similar precision (p=0.234). There was no effect of body mass index on the results in both groups. CONCLUSION Although different extra-medullary tibial cutting guides with and without a spike can reproducibly impart a desired posterior tibial slope in TKA, we concluded that a spiked guide was considered user-friendly.

[1]  Zong-ke Zhou,et al.  The effect of posterior tibial slope on knee flexion in posterior-stabilized total knee arthroplasty , 2013, Knee Surgery, Sports Traumatology, Arthroscopy.

[2]  B. Ravi,et al.  Extramedullary versus intramedullary tibial cutting guides in megaprosthetic total knee replacement , 2012, Journal of Orthopaedic Surgery and Research.

[3]  E. Schemitsch,et al.  Computer navigation vs extramedullary guide for sagittal alignment of tibial components: radiographic study and meta-analysis. , 2012, The Journal of arthroplasty.

[4]  H. Ağuş,et al.  Radiological analysis of closed-wedge high tibial osteotomy. , 2012, Eklem hastaliklari ve cerrahisi = Joint diseases & related surgery.

[5]  Simon J. Wall,et al.  Computer-assisted techniques versus conventional guides for component alignment in total knee arthroplasty: a randomized controlled trial. , 2011, The Journal of bone and joint surgery. American volume.

[6]  I. Learmonth,et al.  Does improved instrumentation result in better component alignment in total knee arthroplasty? , 2011, Orthopedic reviews.

[7]  Seung-Baik Kang,et al.  The accuracy of intramedullary tibial guide of sagittal alignment of PCL-substituting total knee arthroplasty , 2010, Knee Surgery, Sports Traumatology, Arthroscopy.

[8]  P. Brooks Seven cuts to the perfect total knee. , 2009, Orthopedics.

[9]  S. Yeo,et al.  Computer-assisted minimally invasive total knee arthroplasty compared with standard total knee arthroplasty. Surgical technique. , 2009, The Journal of bone and joint surgery. American volume.

[10]  Y. In,et al.  Factors affecting flexion gap tightness in cruciate-retaining total knee arthroplasty. , 2009, The Journal of arthroplasty.

[11]  M. Tingart,et al.  Minimal invasive and computer assisted total knee replacement compared with the conventional technique: a prospective, randomised trial , 2008, Knee Surgery, Sports Traumatology, Arthroscopy.

[12]  H. Chong,et al.  Computer-assisted minimally invasive total knee arthroplasty compared with standard total knee arthroplasty. A prospective, randomized study. , 2008, The Journal of bone and joint surgery. American volume.

[13]  Pak Lin Chin,et al.  Randomized control trial comparing radiographic total knee arthroplasty implant placement using computer navigation versus conventional technique. , 2005, The Journal of arthroplasty.

[14]  S. Banks,et al.  The influence of tibial slope on maximal flexion after total knee arthroplasty , 2005, Knee Surgery, Sports Traumatology, Arthroscopy.

[15]  D. Zurakowski,et al.  Alignment in total knee arthroplasty. A comparison of computer-assisted surgery with the conventional technique. , 2004, The Journal of bone and joint surgery. British volume.

[16]  B. Waelchli,et al.  Dislocation of the polyethylene inlay due to anterior tibial slope in revision total knee arthroplasty , 2001, Knee Surgery, Sports Traumatology, Arthroscopy.

[17]  M. Akagi,et al.  The Bisurface Total Knee Replacement: A Unique Design for Flexion Four-to-Nine-Year Follow-up Study* , 2000, The Journal of bone and joint surgery. American volume.

[18]  D A Dennis,et al.  In Vivo Anteroposterior Femorotibial Translation of Total Knee Arthroplasty: A Multicenter Analysis , 1998, Clinical orthopaedics and related research.

[19]  S. Harwin,et al.  Influence of intramedullary versus extramedullary alignment guides on final total knee arthroplasty component position: a radiographic analysis. , 1998, The Journal of arthroplasty.

[20]  J. Lonner,et al.  Effect of Rotation and Knee Flexion on Radiographic Alignment in Total Knee Arthroplasties , 1996, Clinical orthopaedics and related research.

[21]  M. Bonnin,et al.  Tibial translation after anterior cruciate ligament rupture. Two radiological tests compared. , 1994, The Journal of bone and joint surgery. British volume.

[22]  K A Krackow,et al.  A mathematical analysis of the effect of flexion and rotation on apparent varus/valgus alignment at the knee. , 1990, Orthopedics.

[23]  L. Whiteside,et al.  The effect of posterior tibial slope on knee stability after Ortholoc total knee arthroplasty. , 1988, The Journal of arthroplasty.

[24]  M A Freeman,et al.  Alignment in total knee arthroplasty. Correlated biomechanical and clinical observations. , 1983, Clinical orthopaedics and related research.