Assessment of a multi-species in situ FTIR for precise atmospheric greenhouse gas observations

Abstract. We thoroughly evaluate the performance of a multi-species, in situ Fourier transform infrared (FTIR) analyser with respect to high-accuracy needs for greenhouse gas monitoring networks. The in situ FTIR analyser is shown to measure CO2, CO, CH4 and N2O mole fractions continuously, all with better reproducibility than the inter-laboratory compatibility (ILC) goals, requested by the World Meteorological Organization (WMO) for the Global Atmosphere Watch (GAW) programme. Simultaneously determined δ13CO2 reaches reproducibility as good as 0.03‰. Second-order dependencies between the measured components and the thermodynamic properties of the sample, (temperature, pressure and flow rate) and the cross sensitivities among the sample constituents are investigated and quantified. We describe an improved sample delivery and control system that minimises the pressure and flow rate variations, making post-processing corrections for those quantities non-essential. Temperature disequilibrium effects resulting from the evacuation of the sample cell are quantified and improved by the usage of a faster temperature sensor. The instrument has proven to be linear for all measured components in the ambient concentration range. The temporal stability of the instrument is characterised on different time scales. Instrument drifts on a weekly time scale are only observed for CH4 (0.04 nmol mol−1 day−1) and δ13CO2 (0.02‰ day−1). Based on 10 months of continuously collected quality control measures, the long-term reproducibility of the instrument is estimated to ±0.016 μmol mol−1 CO2, ±0.03‰ δ13CO2, ±0.14 nmol mol−1 CH4, ±0.1 nmol mol−1 CO and ±0.04 nmol mol−1 N2O. We propose a calibration and quality control scheme with weekly calibrations of the instrument that is sufficient to reach WMO-GAW inter-laboratory compatibility goals.

[1]  M. Kaul,et al.  The H2/CO ratio of emissions from combustion sources: comparison of top-down with bottom-up measurements in southwest Germany , 2009 .

[2]  P. Fraser,et al.  THE UOW FTIR TRACE GAS ANALYSER: COMPARISON WITH LOFLO, AGAGE AND TANK MEASUREMENTS AT CAPE GRIM AND GASLAB , 2010 .

[3]  Carl Ekdahl,et al.  Atmospheric carbon dioxide variations at Mauna Loa Observatory, Hawaii , 1976 .

[4]  D. Griffith,et al.  A Fourier transform infrared trace gas and isotope analyser for atmospheric applications , 2012 .

[5]  D. Griffith,et al.  Precision trace gas analysis by FT-IR spectroscopy. 2. The 13C/12C isotope ratio of CO2. , 2000, Analytical chemistry.

[6]  D. Griffith,et al.  A Fourier transform infrared trace gas analyser for atmospheric applications , 2012 .

[7]  Colm Sweeney,et al.  Accurate measurements of carbon monoxide in humid air using the cavity ring-down spectroscopy (CRDS) technique , 2012 .

[8]  R. Francey,et al.  Measuring atmospheric carbon dioxide—the calibration challenge , 2003 .

[9]  P. Ciais,et al.  Ten years of CO 2 , CH 4 , CO and N 2 O fluxes over Western Europe inferred from atmospheric measurements at Mace Head, Ireland , 2008 .

[10]  M. Heimann,et al.  Continuous low-maintenance CO 2 /CH 4 /H 2 O measurements at the Zotino Tall Tower Observatory (ZOTTO) in Central Siberia , 2010 .

[11]  Michael Krystek,et al.  A weighted total least-squares algorithm for fitting a straight line , 2007 .

[12]  J. Hodges,et al.  The air-broadened, near-infrared CO2 line shape in the spectrally isolated regime: evidence of simultaneous Dicke narrowing and speed dependence. , 2011, The Journal of chemical physics.

[13]  D. Worthy,et al.  Evaluation of a cavity ring-down spectrometer for in situ observations of 13 CO 2 , 2012 .

[14]  Christoph Zellweger,et al.  Evaluation of new laser spectrometer techniques for in-situ carbon monoxide measurements , 2012 .

[15]  Eric R. Crosson,et al.  High-accuracy continuous airborne measurements of greenhouse gases (CO2 and CH4) using the cavity ring-down spectroscopy (CRDS) technique , 2010 .

[16]  Gang Li,et al.  The HITRAN 2008 molecular spectroscopic database , 2005 .

[17]  J. Klausen,et al.  WMO/GAW Glossary of QA/QC-Related Terminology , 2008 .

[18]  P. Werle,et al.  The limits of signal averaging in atmospheric trace-gas monitoring by tunable diode-laser absorption spectroscopy (TDLAS) , 1993 .

[19]  D. Griffith,et al.  Precision trace gas analysis by FT-IR spectroscopy. 1. Simultaneous analysis of CO2, CH4, N2O, and CO in air. , 2000, Analytical chemistry.

[20]  D. Griffith Synthetic Calibration and Quantitative Analysis of Gas-Phase FT-IR Spectra , 1996 .

[21]  Colm Sweeney,et al.  High accuracy measurements of dry mole fractions of carbon dioxide and methane in humid air , 2012 .

[22]  Manuela Racki Canadian Baseline Program : summary of progress to 1998 : an overview of the measurements underway in the Canadian Baseline Program, and results to date , 1999 .

[23]  I. Levin,et al.  Feasibility study of using a "travelling" CO2 and CH4 instrument to validate continuous in situ measurement stations , 2012 .

[24]  M. Kawasaki,et al.  Buffer-gas pressure broadening for the (3 0(0) 1)III <-- (0 0 0) band of CO2 measured with continuous-wave cavity ring-down spectroscopy. , 2006, Physical chemistry chemical physics : PCCP.

[25]  David D. Nelson,et al.  Pulsed quantum cascade laser instrument with compact design for rapid, high sensitivity measurements of trace gases in air , 2008 .

[26]  R. Francey,et al.  Modification of air standard composition by diffusive and surface processes , 2005 .