Implementing the complete beam hardening effect of the bowtie filter versus scaling beam intensities: effects on dosimetric applications in computed tomography

Abstract. The bowtie filter is an essential element of computed tomography scanners. Implementation of this filter in a Monte Carlo dosimetry platform can be based on Turner’s method, which describes how to measure the filter thickness and relate the x-ray beam as a function of bowtie angle to the central beam. In that application, the beam hardening is accounted for by means of weighting factors that are associated to the photons according to their position (fan angle) and energy. We assessed an alternative approximation in which the photon spectrum is given a fan angle-dependent scaling factor. The aim of our investigation was to evaluate the effects on dose accuracy estimation when using the gold standard bowtie filter method versus a beam scaling approximation method. In particular, we wanted to assess the percentage dose differences between the two methods for several water thicknesses representative for different patients of different body mass index. The largest percentage differences were found for the thickest part of the bowtie filter and increased with patient size.

[1]  I. Kawrakow,et al.  History by history statistical estimators in the BEAM code system. , 2002, Medical physics.

[2]  J J DeMarco,et al.  A Monte Carlo-based method to estimate radiation dose from spiral CT: from phantom testing to patient-specific models , 2003, Physics in medicine and biology.

[3]  J H Siewerdsen,et al.  Spektr: a computational tool for x-ray spectral analysis and imaging system optimization. , 2004, Medical physics.

[4]  John M. Boone Spectral modeling and compilation of quantum fluence in radiography and mammography , 1998, Medical Imaging.

[5]  J. Boone,et al.  Size-Specific Dose Estimates (SSDE) in Pediatric and Adult Body CT Examinations , 2011 .

[6]  Cynthia H McCollough,et al.  A method to generate equivalent energy spectra and filtration models based on measurement for multidetector CT Monte Carlo dosimetry simulations. , 2009, Medical physics.

[7]  H Bosmans,et al.  Bowtie filtration for dedicated cone beam CT of the head and neck: a simulation study. , 2013, The British journal of radiology.

[8]  C J Martin,et al.  Effective dose: how should it be applied to medical exposures? , 2007, The British journal of radiology.

[9]  R Bogaerts,et al.  Monte Carlo modeling for dose assessment in cone beam CT for oral and maxillofacial applications. , 2013, Medical physics.

[10]  L. Goldman Principles of CT and CT Technology* , 2007, Journal of Nuclear Medicine Technology.

[11]  W. Kalender,et al.  Multisection CT protocols: sex- and age-specific conversion factors used to determine effective dose from dose-length product. , 2010, Radiology.