Proportional — Multiresonant current controller for harmonic elimination in stand-alone DFIG wind power systems

This paper proposes an improved harmonic elimination strategy for the stator output voltage of a stand-alone doubly-fed induction generator (DFIG) feeding a nonlinear load. The proposed elimination method is investigated based on a proportional plus multi-resonant current controller using the stationary reference frame, which is implemented in the rotor-side converter. The aim of the current controller is to achieve the satisfactory performance of rotor currents regulated at harmonic frequencies in order to eliminate fifth and seventh harmonic components in the stator output voltage. As a result, the control scheme allows the DFIG to deliver a pure sinusoidal stator voltage. The proposed control scheme was tested by experiments with 2.2kW DFIG feeding a nonlinear load to verify the feasibility and effectiveness in terms of harmonic compensation performance.

[1]  Luis Marroyo,et al.  Ride Through of Wind Turbines With Doubly Fed Induction Generator Under Symmetrical Voltage Dips , 2009, IEEE Transactions on Industrial Electronics.

[2]  Wlodzimierz Koczara,et al.  DFIG-Based Power Generation System With UPS Function for Variable-Speed Applications , 2008, IEEE Transactions on Industrial Electronics.

[3]  Shang Deshun Doubly Fed Induction Generator for Wind Turbines , 2003 .

[4]  R. W. De Doncker,et al.  Doubly fed induction generator systems for wind turbines , 2002 .

[5]  E. Monmasson,et al.  Design of an output LC filter for a doubly fed induction generator supplying non-linear loads for aircraft applications , 2004, 2004 IEEE International Symposium on Industrial Electronics.

[6]  J. Clare,et al.  Control System for Unbalanced Operation of Stand-Alone Doubly Fed Induction Generators , 2007, IEEE Transactions on Energy Conversion.

[7]  Amit K. Jain,et al.  Wound Rotor Induction Generator With Sensorless Control and Integrated Active Filter for Feeding Nonlinear Loads in a Stand-Alone Grid , 2008, IEEE Transactions on Industrial Electronics.

[8]  S. Arnalte,et al.  Direct Power Control Applied to Doubly Fed Induction Generator Under Unbalanced Grid Voltage Conditions , 2008, IEEE Transactions on Power Electronics.

[9]  J.A. Ferreira,et al.  Operation of Grid-Connected DFIG Under Unbalanced Grid Voltage Condition , 2009, IEEE Transactions on Energy Conversion.

[10]  Hong-Hee Lee,et al.  An Improved Control Strategy Using a PI-Resonant Controller for an Unbalanced Stand-Alone Doubly-Fed Induction Generator , 2010 .