Super-resolution Microscopy at Cryogenic Temperatures Using Solid Immersion Lenses.

Our mechanistic understanding of cell function depends on imaging biological processes in cells with molecular resolution. Super-resolution fluorescence microscopy plays a crucial role by reporting cellular ultrastructure with 20-30 nm resolution. However, this resolution is insufficient to image macro-molecular machinery at work. A path to improve resolution is to image under cryogenic conditions, which substantially increases the brightness of most fluorophores and preserves native ultrastructure much better than chemical fixatives. Cryogenic conditions are, however, underutilized because of the lack of compatible high numerical aperture (NA) objectives. Here we describe a protocol for the use of super-hemispherical solid immersion lenses (superSILs) to achieve super-resolution imaging at cryogenic temperatures with an effective NA of 2.17 and resolution of ~10 nm.

[1]  Benji C. Bateman,et al.  Solid immersion microscopy images cells under cryogenic conditions with 12 nm resolution , 2019, Communications Biology.

[2]  G. Turrigiano,et al.  High-numerical-aperture cryogenic light microscopy for increased precision of superresolution reconstructions , 2017, Proceedings of the National Academy of Sciences.

[3]  Johannes E. Schindelin,et al.  The ImageJ ecosystem: An open platform for biomedical image analysis , 2015, Molecular reproduction and development.

[4]  B. Giepmans,et al.  Correlated light and electron microscopy: ultrastructure lights up! , 2015, Nature Methods.

[5]  Yongdeng Zhang,et al.  Three-dimensional super-resolution protein localization correlated with vitrified cellular context , 2015, Scientific Reports.

[6]  Toby D. M. Bell,et al.  Image artifacts in Single Molecule Localization Microscopy: why optimization of sample preparation protocols matters , 2015, Scientific Reports.

[7]  Henry Pinkard,et al.  Advanced methods of microscope control using μManager software. , 2014, Journal of biological methods.

[8]  Ian M. Dobbie,et al.  Super-Resolution Microscopy Using Standard Fluorescent Proteins in Intact Cells under Cryo-Conditions , 2014, Nano letters.

[9]  Guy M. Hagen,et al.  ThunderSTORM: a comprehensive ImageJ plug-in for PALM and STORM data analysis and super-resolution imaging , 2014, Bioinform..

[10]  Xudong Chen,et al.  A complete and computationally efficient numerical model of aplanatic solid immersion lens scanning microscope. , 2013, Optics express.

[11]  M. Somekh,et al.  Imaging performance of widefield solid immersion lens microscopy. , 2007, Applied optics.

[12]  Michael J Rust,et al.  Sub-diffraction-limit imaging by stochastic optical reconstruction microscopy (STORM) , 2006, Nature Methods.

[13]  J. Lippincott-Schwartz,et al.  Imaging Intracellular Fluorescent Proteins at Nanometer Resolution , 2006, Science.

[14]  W. Webb,et al.  Precise nanometer localization analysis for individual fluorescent probes. , 2002, Biophysical journal.

[15]  M. Gustafsson Surpassing the lateral resolution limit by a factor of two using structured illumination microscopy , 2000, Journal of microscopy.

[16]  Bruce D. Terris,et al.  Near‐field optical data storage using a solid immersion lens , 1994 .

[17]  S. Hell,et al.  Breaking the diffraction resolution limit by stimulated emission: stimulated-emission-depletion fluorescence microscopy. , 1994, Optics letters.

[18]  J. Dubochet,et al.  VITRIFICATION OF PURE WATER FOR ELECTRON MICROSCOPY , 1981 .