The Effects of Sterilization Procedures on the Cutting Efficiency of Endodontic Instruments: A Systematic Review and Network Meta-Analysis

Sterilization processes guarantee the sterility of dental instruments but can negatively affect instrument features by altering their physical and mechanical properties. The endodontic instrumentation can undergo a series of alterations, ranging from corrosion to variation in the cutting angle and then changes in the torsional properties and torsional fatigue resistance. This systematic literature review and meta-analysis aims to investigate alterations to the cutting efficiency of endodontic instruments that are induced by procedures for their disinfection and sterilization. Methodologies adopted for this investigation follow the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analysis) guidelines. The following were used as search terms on PubMed and Scopus: “endodontic sterilization”, “endodontic autoclave”, “cyclic fatigue”, “torsional”, “cutting efficiency”, “sterilization”, “surface characteristics”, and “corrosion”. At the end of the selection process, 36 articles were identified, and seven of them are included in this systematic review. The results of a meta-analysis conducted for the use of 10 autoclaving cycles shows a standardized mean difference (SMD) of 0.80 with a p-value equal to 0.04 with respect to effect on cutting efficiency. The network meta-analysis, through direct and indirect comparison between the different autoclave cycles (0, 1, 5, 10, and 15 cycles), revealed that treatment involving 15 autoclave cycles produced the most robust results in terms of having the greatest effects in terms of altered cutting efficiency with a probability of 57.7% and a SUCRA (surface under the cumulative ranking) of 80%. The alterations in the effects on cutting efficiency appear to be triggered after five cycles of sterilization by heat (autoclave). In conclusion, the meta-analysis of the data indicates that the autoclave sterilization protocol must not be repeated more than five times to preserve cutting efficiency. Within the limitations of this review, we can therefore establish that sterilization by autoclaving alone results in steel and NiTi instruments becoming less efficient in cutting after five cycles, as measured by a reduction in cutting efficiency.

[1]  S. Imazato,et al.  Autoclave sterilization of dental handpieces: A literature review. , 2020, Journal of prosthodontic research.

[2]  Giuseppe Troiano,et al.  Management of Instrument Sterilization Workflow in Endodontics: A Systematic Review and Meta-Analysis , 2020, International journal of dentistry.

[3]  D. Ciavarella,et al.  Surface Alterations Induced on Endodontic Instruments by Sterilization Processes, Analyzed with Atomic Force Microscopy: A Systematic Review , 2019 .

[4]  C. Keskin,et al.  Torsional Resistance of ProGlider, Hyflex EDM, and One G Glide Path Instruments. , 2019, Journal of endodontics.

[5]  L. Laino,et al.  Effects of Hot Sterilization on Torsional Properties of Endodontic Instruments: Systematic Review with Meta-Analysis , 2019, Materials.

[6]  L. Lo Muzio,et al.  Sterilisation in Dentistry: A Review of the Literature , 2019, International journal of dentistry.

[7]  E. Schäfer,et al.  New thermomechanically treated NiTi alloys – a review , 2018, International endodontic journal.

[8]  B. Hou,et al.  [Metallurgic behavior and mechanical property of nickel-titanium endodontic files made by 3 heat treatment techniques]. , 2018, Zhonghua kou qiang yi xue za zhi = Zhonghua kouqiang yixue zazhi = Chinese journal of stomatology.

[9]  Jeannette Dabanch,et al.  Importancia del proceso de limpieza y desinfección de superficies críticas en un servicio dental. Impacto de un programa de intervención , 2018 .

[10]  T. Özyürek,et al.  Effect of multiple autoclave cycles on the surface roughness of HyFlex CM and HyFlex EDM files: an atomic force microscopy study , 2018, Clinical Oral Investigations.

[11]  Bilal Mourshed,et al.  The Effect of surface topographical changes of two different surface treatments rotary instrument , 2018, Journal of clinical and experimental dentistry.

[12]  M. Khabiri,et al.  The Effect of Autoclave Sterilization on Resistance to Cyclic Fatigue of Hero Endodontic File #642 (6%) at Two Artificial Curvature , 2017, Journal of dentistry.

[13]  D. Ciavarella,et al.  Centering Ability of ProTaper Next and WaveOne Classic in J-Shape Simulated Root Canals , 2016, TheScientificWorldJournal.

[14]  B. Peng,et al.  Effect of autoclave sterilization on the cyclic fatigue resistance of thermally treated Nickel-Titanium instruments. , 2016, International endodontic journal.

[15]  C. Elias,et al.  Influence of Surface Roughness on the Fatigue Life of Nickel-Titanium Rotary Endodontic Instruments. , 2016, Journal of endodontics.

[16]  H. Razavian,et al.  Effect of Autoclave Cycles on Surface Characteristics of S-File Evaluated by Scanning Electron Microscopy , 2015, Iranian endodontic journal.

[17]  S. Stanciu,et al.  Structural characterization and adhesion appraisal of TiN and TiCN coatings deposited by CAE-PVD technique on a new carbide composite cutting tool , 2015 .

[18]  Mahima Tilakchand,et al.  The effect of multiple autoclave cycles on the surface of rotary nickel-titanium endodontic files: An in vitro atomic force microscopy investigation , 2015, Journal of conservative dentistry : JCD.

[19]  Mark D. Roberts,et al.  Effect of repeated simulated clinical use and sterilization on the cutting efficiency and flexibility of Hyflex CM nickel-titanium rotary files. , 2015, Journal of endodontics.

[20]  S. Deepthi,et al.  Pathological evaluation for sterilization of routinely used prosthodontic and endodontic instruments , 2015, Journal of International Society of Preventive & Community Dentistry.

[21]  V. Gopikrishna,et al.  CRIS Guidelines (Checklist for Reporting In-vitro Studies): A concept note on the need for standardized guidelines for improving quality and transparency in reporting in-vitro studies in experimental dental research , 2014, Journal of conservative dentistry : JCD.

[22]  A. Arias,et al.  Influence of clinical usage of GT and GTX files on cyclic fatigue resistance. , 2014, International endodontic journal.

[23]  K. Abinaya,et al.  Efficacy of peracetic acid in rapid disinfection of Resilon and gutta-percha cones compared with sodium hypochlorite, chlorhexidine, and povidone-iodine. , 2013, Journal of endodontics.

[24]  H. Duncan,et al.  Endodontic instrument fracture: causes and prevention , 2013, BDJ.

[25]  T. Fang,et al.  Study of deformation and shape recovery of NiTi nanowires under torsion , 2013, Journal of Molecular Modeling.

[26]  V. D’antò,et al.  Effect of autoclaving on the surfaces of TiN -coated and conventional nickel-titanium rotary instruments. , 2012, International endodontic journal.

[27]  B. Bergeron,et al.  The effect of autoclaving on torsional moment of two nickel-titanium endodontic files. , 2012, International endodontic journal.

[28]  Mark D. Roberts,et al.  Comparison of autoclaving effects on torsional deformation and fracture resistance of three innovative endodontic file systems. , 2011, Journal of endodontics.

[29]  D. Fayyad,et al.  Cutting efficiency of twisted versus machined nickel-titanium endodontic files. , 2011, Journal of endodontics.

[30]  A. Morrison,et al.  Dental burs and endodontic files: are routine sterilization procedures effective? , 2010, Texas dental journal.

[31]  J. Ioannidis,et al.  The PRISMA Statement for Reporting Systematic Reviews and Meta-Analyses of Studies That Evaluate Health Care Interventions: Explanation and Elaboration , 2009, Annals of Internal Medicine [serial online].

[32]  D. Moher,et al.  Preferred Reporting Items for Systematic Reviews and Meta-Analyses: The PRISMA Statement , 2009, BMJ : British Medical Journal.

[33]  Alison J.E. Qualtrough,et al.  Factors contributing to the separation of endodontic files , 2008, BDJ.

[34]  A. Valleron,et al.  Risk Assessment of Transmission of Sporadic Creutzfeldt-Jakob Disease in Endodontic Practice in Absence of Adequate Prion Inactivation , 2007, PloS one.

[35]  P. Marsh,et al.  Cleanability of dental instruments – implications of residual protein and risks from Creutzfeldt-Jakob disease , 2007, BDJ.

[36]  J. Bagg,et al.  Pre-sterilisation cleaning of re-usable instruments in general dental practice , 2007, BDJ.

[37]  A C D Viana,et al.  Influence of sterilization on mechanical properties and fatigue resistance of nickel-titanium rotary endodontic instruments. , 2006, International endodontic journal.

[38]  Marvin B Golberg,et al.  The sterility of dental burs directly from the manufacturer. , 2006, Journal of esthetic and restorative dentistry : official publication of the American Academy of Esthetic Dentistry ... [et al.].

[39]  E. Berutti,et al.  Influence of sodium hypochlorite on fracture properties and corrosion of ProTaper Rotary instruments. , 2006, International endodontic journal.

[40]  E. Schäfer Effect of sterilization on the cutting efficiency of PVD-coated nickel-titanium endodontic instruments. , 2002, International endodontic journal.

[41]  M. T. Filho,et al.  The use of ultrasound for cleaning the surface of stainless steel and nickel-titanium endodontic instruments. , 2001, International endodontic journal.

[42]  N. Richards,et al.  Torsional properties of stainless-steel and nickel-titanium files after multiple autoclave sterilizations. , 2000, Journal of endodontics.

[43]  J. Powers,et al.  Effects of simulated clinical conditions on nickel-titanium rotary files. , 1999, Journal of endodontics.

[44]  Teresa Roberta Tripib,et al.  Effect of sterilization on the cutting efficiency of rotary nickel-titanium endodontic files , 1999 .

[45]  P. Wilson,et al.  Cutting efficiency of nickel-titanium endodontic instruments and the effect of sodium hypochlorite treatment. , 1998, Journal of endodontics.

[46]  R. Kolstad How well does the Chemiclave sterilize handpieces? , 1998, Journal of the American Dental Association.

[47]  J. Silvaggio,et al.  Effect of heat sterilization on the torsional properties of rotary nickel-titanium endodontic files. , 1997, Journal of endodontics.

[48]  T. Lwin,et al.  Effects of cleaning, disinfection, and sterilization procedures on the cutting efficiency of endodontic files. , 1996, Journal of endodontics.

[49]  T. Lwin,et al.  Measurement of the cutting efficiency of endodontic instruments: a new concept. , 1996, Journal of endodontics.

[50]  O. Zmener,et al.  Cleaning of endodontic instruments before use. , 1995, Endodontics & dental traumatology.

[51]  R. L. Cooley,et al.  Effect of sterilization on the strength and cutting efficiency of twist drills. , 1990, Quintessence international.

[52]  S. Montgomery,et al.  Effectiveness of a brush in removing postinstrumentation canal debris. , 1990, Journal of endodontics.

[53]  C. E. Brown,et al.  The effects of steam sterilization and usage on cutting efficiency of endodontic instruments. , 1989, Journal of endodontics.

[54]  R. G. Craig,et al.  Effect of sterilization and irrigants on the cutting ability of stainless steel files. , 1983, Journal of endodontics.

[55]  R. C. Nelson,et al.  The effect of autoclave sterilization on endodontic files. , 1983, Oral surgery, oral medicine, and oral pathology.

[56]  J. Moser,et al.  A method to determine the cutting efficiency of root canal instruments in rotary motion. , 1980, Journal of endodontics.

[57]  S. Sorin,et al.  Cutting efficiency of endodontic reamers. , 1973, Oral surgery, oral medicine, and oral pathology.

[58]  H. Fromme,et al.  Treatment of dental root canals and the marginal contact between filling material and tooth, studied by scanning electronic microscopy. , 1972, Journal of the British Endodontic Society.

[59]  O. Molven A comparison of the dentin-removing ability of five root canal instruments. , 1970, Scandinavian journal of dental research.

[60]  I. Antoniac,et al.  Ni-Ti ROTARY INSTRUMENT FRACTURE ANALYSIS AFTER CLINICAL USE. STRUCTURE CHANGES IN USED INSTRUMENTS , 2016 .

[61]  Vinny R. Sastri Chapter 4 – Material Requirements for Plastics used in Medical Devices , 2010 .

[62]  R. Venkatasubramanian,et al.  Comparison of the effectiveness of sterilizing endodontic files by 4 different methods: an in vitro study. , 2010, Journal of the Indian Society of Pedodontics and Preventive Dentistry.

[63]  G. Condorelli,et al.  Effect of sterilization on the cutting efficiency of rotary nickel-titanium endodontic files. , 1999, Oral surgery, oral medicine, oral pathology, oral radiology, and endodontics.

[64]  C. Canalda-Sahli,et al.  The effect of sterilization on bending and torsional properties of K-files manufactured with different metallic alloys. , 1998, International endodontic journal.

[65]  T. Lwin,et al.  Effects of cleaning, chemical disinfection, and sterilization procedures on the mechanical properties of endodontic instruments. , 1997, Journal of endodontics.

[66]  J. Webber,et al.  A method to determine the cutting efficiency of root canal instruments in linear motion. , 1980, Journal of endodontics.