FSI simulation of asymmetric mitral valve dynamics during diastolic filling

In this article, we present a fluid–structure interaction algorithm accounting for the mutual interaction between two rigid bodies. The algorithm was used to perform a numerical simulation of mitral valve (MV) dynamics during diastolic filling. In numerical simulations of intraventricular flow and MV motion, the asymmetry of the leaflets is often neglected. In this study the MV was rendered as two rigid, asymmetric leaflets. The 2D simulations incorporated the dynamic interaction of blood flow and leaflet motion and an imposed subject-specific, transient left ventricular wall movement obtained from ultrasound recordings. By including the full Jacobian matrix in the algorithm, the speed of the simulation was enhanced by more than 20% compared to using a diagonal Jacobian matrix. Furthermore, our results indicate that important features of the flow field may not be predicted by the use of symmetric leaflets or in the absence of an adequate model for the left atrium.

[1]  Karyn S Kunzelman,et al.  Non-linear fluid-coupled computational model of the mitral valve. , 2005, The Journal of heart valve disease.

[2]  A Redaelli,et al.  Two fluid-structure approaches for 3D simulation of St. Jude Medical bileaflet valve opening. , 2007, Journal of applied biomaterials & biomechanics : JABB.

[3]  Jens-Dominik Mueller,et al.  Validation of a fluid–structure interaction model for a bileaflet mechanical heart valve , 2008 .

[4]  C. Peskin Flow patterns around heart valves: A numerical method , 1972 .

[5]  C. Peskin,et al.  A three-dimensional computer model of the human heart for studying cardiac fluid dynamics , 2000, SIGGRAPH 2000.

[6]  H Ihlen,et al.  Diastolic flow pattern in the normal left ventricle. , 1999, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[7]  B J Bellhouse,et al.  Fluid mechanics of a model mitral valve and left ventricle. , 1972, Cardiovascular research.

[8]  Chang Nyung Kim,et al.  Pulsatile blood flows through a bileaflet mechanical heart valve with different approach methods of numerical analysis; pulsatile flows with fixed leaflets and interacted with moving leaflets , 2003 .

[9]  Patrick D. Anderson,et al.  A fluid-structure interaction method with solid-rigid contact for heart valve dynamics , 2006, J. Comput. Phys..

[10]  van de Fn Frans Vosse,et al.  Evaluation of a fictitious domain method for predicting dynamic response of mechanical heart valves , 2004 .

[11]  Quan Long,et al.  Combined CFD/MRI Analysis of Left Ventricular Flow , 2004, Medical Imaging and Augmented Reality.

[12]  G Bashein,et al.  Three-dimensional echocardiographic assessment of annular shape changes in the normal and regurgitant mitral valve. , 2000, American heart journal.

[13]  Chang Nyung Kim,et al.  Numerical Analysis on the Hemodynamics and Leaflet Dynamics in a Bileaflet Mechanical Heart Valve Using a Fluid-Structure Interaction Method , 2009, ASAIO journal.

[14]  R. Padiyar,et al.  Left atrial size and geometry in the intact dog. , 1977, The American journal of physiology.

[15]  T Ebbers,et al.  Three dimensional flow in the human left atrium , 2001, Heart.

[16]  Philippe Pibarot,et al.  New insights into the assessment of the prosthetic valve performance in the presence of subaortic stenosis through a fluid-structure interaction model. , 2007, Journal of biomechanics.

[17]  Bjørn Skallerud,et al.  Nonlinear solid finite element analysis of mitral valves with heterogeneous leaflet layers , 2009 .

[18]  B Skallerud,et al.  Modeling active muscle contraction in mitral valve leaflets during systole: a first approach , 2011, Biomechanics and modeling in mechanobiology.

[19]  I. C. Howard,et al.  An approach to the simulation of fluid-structure interaction in the aortic valve. , 2006, Journal of biomechanics.

[20]  X. Luob,et al.  Effect of ventricle motion on the dynamic behaviour of chorded mitral valves , 2008 .

[21]  D N Firmin,et al.  The influence of inflow boundary conditions on intra left ventricle flow predictions. , 2003, Journal of biomechanical engineering.

[22]  Simulation of Blood Flow through Stenosed Artery , 2013 .

[23]  Mitra Tzi - ker ChiuehComputer S ien e DepartmentState Three-Dimensional Computer , 2000 .

[24]  Jürgen Hennig,et al.  Fluid-dynamic modeling of the human left ventricle: methodology and application to surgical ventricular reconstruction. , 2009, The Annals of thoracic surgery.

[25]  J Strackee,et al.  Determinants of the occurrence of vortex rings in the left ventricle during diastole. , 1990, Journal of biomechanics.

[26]  Matteo Astorino,et al.  Fluid-structure interaction and multi-body contact. Application to aortic valves , 2009 .

[27]  Jan Vierendeels,et al.  Analysis and stabilization of fluid-structure interaction algorithm for rigid-body motion , 2005 .

[28]  Umberto Morbiducci,et al.  Numerical simulation of the dynamics of a bileaflet prosthetic heart valve using a fluid-structure interaction approach. , 2008, Journal of biomechanics.

[29]  Patrick Patrick Anderson,et al.  Fluid-solid interactions: modeling, simulation, bio-mechanical applications A three-dimensional fluid-structure interaction method for heart valve modelling , 2005 .

[30]  Fotis Sotiropoulos,et al.  Curvilinear immersed boundary method for simulating fluid structure interaction with complex 3D rigid bodies , 2008, J. Comput. Phys..

[31]  Jan Vierendeels,et al.  Comparison of the hemodynamic and thrombogenic performance of two bileaflet mechanical heart valves using a CFD/FSI model. , 2007, Journal of biomechanical engineering.

[32]  Dimitris N. Metaxas,et al.  Atrioventricular Blood Flow Simulation Based on Patient-Specific Data , 2009, FIMH.

[33]  Filip Johnsson,et al.  Fluid dynamic modeling of CFB units , 2002 .

[34]  J. M. A. Stijnena,et al.  Evaluation of a fictitious domain method for predicting dynamic response of mechanical heart valves , 2004 .

[35]  Gianni Pedrizzetti,et al.  Flow-driven opening of a valvular leaflet , 2006, Journal of Fluid Mechanics.

[36]  Gianni Pedrizzetti,et al.  Vortex dynamics in a model left ventricle during filling , 2002 .

[37]  Chang Nyung Kim,et al.  Characteristics of Pulsatile Blood Flow Through the Curved Bileaflet Mechanical Heart Valve Installed in Two Different Types of Blood Vessels: Velocity and Pressure of Blood Flow , 2006, ASAIO journal.

[38]  J Vierendeels,et al.  Validation of a Fluid–Structure Interaction Model of a Heart Valve using the Dynamic Mesh Method in Fluent , 2004, Computer methods in biomechanics and biomedical engineering.

[39]  F. N. van de Vosse,et al.  Computational analysis of ventricular valve–valve interaction: Influence of flow conditions , 2009 .

[40]  R. Cheng,et al.  Three-Dimensional Fluid-Structure Interaction Simulation of Bileaflet Mechanical Heart Valve Flow Dynamics , 2004, Annals of Biomedical Engineering.

[41]  E. M. Pedersen,et al.  Two-dimensional mitral flow velocity profiles in pig models using epicardial Doppler echocardiography. , 1994, Journal of the American College of Cardiology.

[42]  H Reul,et al.  Fluid mechanics of the natural mitral valve. , 1981, Journal of biomechanics.

[43]  C. Peskin,et al.  Fluid Dynamics of the Heart and its Valves , 1996 .

[44]  Patrick Segers,et al.  Predicting ATS Open Pivot heart valve performance with computational fluid dynamics. , 2005, The Journal of heart valve disease.

[45]  Yos S. Morsi,et al.  Transient fluid–structure coupling for simulation of a trileaflet heart valve using weak coupling , 2007, Journal of Artificial Organs.

[46]  F P T Baaijens,et al.  A three-dimensional computational analysis of fluid-structure interaction in the aortic valve. , 2003, Journal of biomechanics.