Identification of contact allergens in unmodified rosin using a combination of patch testing and analytical chemistry techniques

Summary In order lo investigate the contact allergens in the unmodified colophony (rosin) used in routine patch testing, preparative chromatographic techniques were used to separate its components which were then patch tested on colophony‐sensitive individuals. The chemical structure of the dermatologically active components was elucidated using mass spectrometry, nuclear magnetic resonance and infra‐red techniques. The study shows that oxidized resin acids are stronger sensitizers than the resin acids themselves, the most potent contact allergen being 7‐oxydehydroahietic acid (purity 92%). At naturally occurring concentrations (relative to abietic acid) all unoxidized resin acids were found to play an insignificant part, individually, in colophony dermatitis, except abietic acid (purity 99%), which was found to be a weak but important allergen. The commercial Trolab abietic acid preparation (unknown purity) was found to be dermatologically more active than purified abietic acid.

[1]  K. Krohn,et al.  Contact allergy due to colophony , 1993, Contact dermatitis.

[2]  K. Krohn,et al.  Contact allergy due to colophony (VII), Sensitizing studies with oxidation products of abietic and related acids , 1990, Contact dermatitis.

[3]  B M Hausen,et al.  Contact allergy due to colophony , 1989, Contact dermatitis.

[4]  A. Karlberg,et al.  Contact allergy to dehydroabietic acid derivatives isolated from Portuguese colophony , 1988, Contact dermatitis.

[5]  U. Hacksell,et al.  Identification of 15‐Hydroperoxyabietic Acid as a Contact Allergen in Portuguese Colophony , 1988, The Journal of pharmacy and pharmacology.

[6]  S. K. Ng,et al.  Airborne contact dermatitis to colophony in soldering flux , 1987, Contact dermatitis.

[7]  A. Karlberg,et al.  Is abietic acid the allergenic component of colophony? , 1985, Contact dermatitis.

[8]  D. Foster,et al.  Qualitative and quantitative analysis of diterpene resin acids by glass capillary gas—liquid chromatography , 1982 .

[9]  H. Maibach,et al.  Occupational Contact Dermatitis: Clinical and Chemical Aspects , 1982 .

[10]  A. Karlberg,et al.  Allergenic potential of abietic acid, colophony and pine resin‐HA , 1980, Contact dermatitis.

[11]  J. Pepys,et al.  Asthma due to inhaled chemical agents—fumes from ‘Multicore’ soldering flux and colophony resin , 1976, Clinical allergy.

[12]  A. Kligman,et al.  The Identification of Contact Allergens by Animal Assay. the Guinea Pig Maximization Test , 1969 .