Deep tissue fluorescence imaging and in vivo biological applications

Abstract. We describe a novel technical approach with enhanced fluorescence detection capabilities in two-photon microscopy that achieves deep tissue imaging, while maintaining micron resolution. Compared to conventional two-photon microscopy, greater imaging depth is achieved by more efficient harvesting of fluorescence photons propagating in multiple-scattering media. The system maintains the conventional two-photon microscopy scheme for excitation. However, for fluorescence collection the detection system harvests fluorescence photons directly from a wide area of the turbid sample. The detection scheme relies on a wide area detector, minimal optical components and an emission path bathed in a refractive-index-matching fluid that minimizes emission photon losses. This detection scheme proved to be very efficient, allowing us to obtain high resolution images at depths up to 3 mm. This technique was applied to in vivo imaging of the murine small intestine (SI) and colon. The challenge is to image normal and diseased tissue in the whole live animal, while maintaining high resolution imaging at millimeter depth. In Lgr5-GFP mice, we have been successful in imaging Lgr5-eGFP positive stem cells, present in SI and colon crypt bases.

[1]  T. Wilson,et al.  Scanning two photon fluorescence microscopy with extended depth of field , 2006 .

[2]  Anthony J. Durkin,et al.  Fabrication and characterization of silicone-based tissue phantoms with tunable optical properties in the visible and near infrared domain , 2008, SPIE BiOS.

[3]  A. Welch,et al.  A review of the optical properties of biological tissues , 1990 .

[4]  A. Dunn,et al.  Influence of optical properties on two-photon fluorescence imaging in turbid samples. , 2000, Applied optics.

[5]  H. Clevers,et al.  Wnt signalling in stem cells and cancer , 2005, Nature.

[6]  Bruce J. Tromberg,et al.  Combined multiphoton and optical coherence microscopy , 2005, SPIE BiOS.

[7]  W. Birchmeier,et al.  Wnt signalling and its impact on development and cancer , 2008, Nature Reviews Cancer.

[8]  Min Gu,et al.  Penetration depth of single-, two-, and three-photon fluorescence microscopic imaging through human cortex structures: Monte Carlo simulation. , 2003, Applied optics.

[9]  Elizabeth M. C. Hillman,et al.  Spectral Characterization and Unmixing of Intrinsic Contrast in Intact Normal and Diseased Gastric Tissues Using Hyperspectral Two-Photon Microscopy , 2011, PloS one.

[10]  Eric Betzig,et al.  Adaptive optics via pupil segmentation for high-resolution imaging in biological tissues , 2010, Nature Methods.

[11]  Fritjof Helmchen,et al.  Enhanced fluorescence signal in nonlinear microscopy through supplementary fiber-optic light collection. , 2009, Optics express.

[12]  Enrico Gratton,et al.  In vivo deep tissue fluorescence imaging of the murine small intestine and colon , 2012, Other Conferences.

[13]  Winfried Denk,et al.  On the fundamental imaging-depth limit in two-photon microscopy , 2006 .

[14]  W. Denk,et al.  Two-photon laser scanning fluorescence microscopy. , 1990, Science.

[15]  Rafael Yuste,et al.  Two-Photon Imaging with Diffractive Optical Elements , 2009, Front. Neural Circuits.

[16]  M. Levene,et al.  Microprisms for in vivo multilayer cortical imaging. , 2009, Journal of neurophysiology.

[17]  H. Gerritsen,et al.  Imaging of optically thick specimen using two‐photon excitation microscopy , 1999, Microscopy research and technique.

[18]  Christophe Odin,et al.  Out-of-focus fluorescence collection in two-photon microscopy of scattering media , 2008 .

[19]  I. Yaroslavsky,et al.  Optical properties of selected native and coagulated human brain tissues in vitro in the visible and near infrared spectral range. , 2002, Physics in medicine and biology.

[20]  H. Clevers,et al.  Stem cells, self-renewal, and differentiation in the intestinal epithelium. , 2009, Annual review of physiology.

[21]  W. Denk,et al.  Two-photon imaging to a depth of 1000 microm in living brains by use of a Ti:Al2O3 regenerative amplifier. , 2003, Optics letters.

[22]  Enrico Gratton,et al.  Mitigating thermal mechanical damage potential during two-photon dermal imaging. , 2004, Journal of biomedical optics.

[23]  E. Cocker,et al.  Fiber-optic fluorescence imaging , 2005, Nature Methods.

[24]  M. H. Ross,et al.  Histology: A Text and Atlas: With Correlated Cell and Molecular Biology. Eighth Edition, 2018 Authors: Wojciech Pawlina; Michael H. Ross , 2019, Morphologia.

[25]  P. So,et al.  Shack-Hartmann wavefront-sensor-based adaptive optics system for multiphoton microscopy. , 2010, Journal of biomedical optics.

[26]  Enrico Gratton,et al.  Enhancement of imaging depth in turbid media using a wide area detector , 2011, Journal of biophotonics.

[27]  R S Balaban,et al.  Optimizing multiphoton fluorescence microscopy light collection from living tissue by noncontact total emission detection (epiTED) , 2011, Journal of microscopy.

[28]  Jerome Mertz,et al.  Two-photon microscopy in brain tissue: parameters influencing the imaging depth , 2001, Journal of Neuroscience Methods.

[29]  N. Nishimura,et al.  Deep tissue multiphoton microscopy using longer wavelength excitation. , 2009, Optics express.

[30]  H. Clevers,et al.  Identification of stem cells in small intestine and colon by marker gene Lgr5 , 2007, Nature.

[31]  Winfried Denk,et al.  On the fundamental imaging-depth limit in two-photon microscopy , 2004, SPIE Photonics Europe.

[32]  A. Heikal Intracellular coenzymes as natural biomarkers for metabolic activities and mitochondrial anomalies. , 2010, Biomarkers in medicine.

[33]  D. O'Malley,et al.  Chapter 5: Imaging in depth: controversies and opportunities. , 2008, Methods in cell biology.

[34]  D. Sampson,et al.  Contrast and depth enhancement in two-photon microscopy of human skin ex vivo by use of optical clearing agents. , 2005, Optics express.

[35]  Hans Clevers,et al.  Crypt stem cells as the cells-of-origin of intestinal cancer , 2009, Nature.

[36]  Jay R Knutson,et al.  Optimization of multiphoton excitation microscopy by total emission detection using a parabolic light reflector , 2007, Journal of microscopy.

[37]  Aernout Kisteman,et al.  Comparison of penetration depth between two-photon excitation and single-photon excitation in imaging through turbid tissue media , 2000 .