Configuration optimization of dampers for adjacent buildings under seismic excitations

Passive coupling of adjacent structures is known to be an effective method to reduce undesirable vibrations and structural pounding effects. Past results have shown that reducing the number of dampers can considerably decrease the cost of implementation and does not significantly decrease the efficiency of the system. The main objective of this study was to find the optimal arrangement of a limited number of dampers to minimize interstorey drift. Five approaches to solving the resulting bi-level optimization problem are introduced and examined (exhaustive search, inserting dampers, inserting floors, locations of maximum relative velocity and a genetic algorithm) and the numerical efficiency of each method is examined. The results reveal that the inserting damper method is the most efficient and reliable method, particularly for tall structures. It was also found that increasing the number of dampers does not necessarily increase the efficiency of the system. In fact, increasing the number of dampers can exacerbate the dynamic response of the system.

[1]  Ranjan Ganguli,et al.  Optimal placement of trailing-edge flaps for helicopter vibration reduction using response surface methods , 2007 .

[2]  Solomon Tesfamariam,et al.  Seismic Vulnerability Assessment of Reinforced Concrete Buildings Using Hierarchical Fuzzy Rule Base Modeling , 2010 .

[3]  J. N. Yang,et al.  Optimal Placement of Passive Dampers on Seismic and Wind-Excited Buildings using Combinatorial Optimization , 1999 .

[4]  Yl L. Xu,et al.  Closed‐form solution for seismic response of adjacent buildings with linear quadratic Gaussian controllers , 2002 .

[5]  Jm M. Ko,et al.  Experimental investigation of adjacent buildings connected by fluid damper , 1999 .

[6]  S. M. Dumne,et al.  Seismic response analysis of adjacent buildings connected with MR dampers , 2010 .

[7]  R. S. Jangid,et al.  Seismic analysis of structures connected with friction dampers , 2006 .

[8]  J. Douglas Faires,et al.  Numerical Analysis , 1981 .

[9]  R. S. Jangid,et al.  Seismic Response of Adjacent Buildings Connected with Friction Dampers , 2006 .

[10]  Michael Vose The simple genetic algorithm: foundations and theory (complex adaptive systems) , 1999 .

[11]  Mahendra P. Singh,et al.  Optimal placement of dampers for passive response control , 2002 .

[12]  Yi-Qing Ni,et al.  Stochastic optimal coupling-control of adjacent building structures , 2003 .

[13]  Yl L. Xu,et al.  Experimental Seismic Study of Adjacent Buildings with Fluid Dampers , 2003 .

[14]  Hengjia Zhu,et al.  Optimum connecting dampers to reduce the seismic responses of parallel structures , 2011 .

[15]  M. De Angelis,et al.  Optimal passive control of adjacent structures interconnected with nonlinear hysteretic devices , 2007 .

[16]  R. S. Jangid,et al.  Seismic response of dynamically similar adjacent structures connected with viscous dampers , 2010 .

[17]  Jorge J. Moré,et al.  Digital Object Identifier (DOI) 10.1007/s101070100263 , 2001 .

[18]  Hengjia Zhu,et al.  Optimum parameters of Maxwell model-defined dampers used to link adjacent structures , 2005 .

[19]  Yoyong Arfiadi,et al.  Optimum Design of Absorber for MDOF Structures , 1998 .

[20]  W. S. Zhang,et al.  VIBRATION ANALYSIS OF TWO BUILDINGS LINKED BY MAXWELL MODEL-DEFINED FLUID DAMPERS , 2000 .

[21]  Wl L. Qu,et al.  Semi‐active control of seismic response of tall buildings with podium structure using ER/MR dampers , 2001 .

[22]  You-Lin Xu,et al.  Seismic response control of a building complex utilizing passive friction damper: experimental investigation , 2006 .

[23]  The use of optimization procedures in tuning vibration dampers , 2002 .

[24]  M. De Angelis,et al.  A reduced order model for optimal design of 2-mdof adjacent structures connected by hysteretic dampers , 2007 .

[25]  M. F. Golnaraghi,et al.  Optimal design of passive linear suspension using genetic algorithm , 2004 .

[26]  J. Enrique Luco,et al.  Optimal damping between two adjacent elastic structures , 1998 .

[27]  Seung-Yong Ok,et al.  Optimal design of hysteretic dampers connecting adjacent structures using multi-objective genetic algorithm and stochastic linearization method , 2008 .

[28]  Yl L. Xu,et al.  Dynamic characteristics and seismic response of adjacent buildings linked by discrete dampers , 1999 .

[29]  Yl L. Xu,et al.  Dynamic response of damper-connected adjacent buildings under earthquake excitation , 1999 .

[30]  J. Miller Numerical Analysis , 1966, Nature.