Configuration optimization of dampers for adjacent buildings under seismic excitations
暂无分享,去创建一个
[1] Ranjan Ganguli,et al. Optimal placement of trailing-edge flaps for helicopter vibration reduction using response surface methods , 2007 .
[2] Solomon Tesfamariam,et al. Seismic Vulnerability Assessment of Reinforced Concrete Buildings Using Hierarchical Fuzzy Rule Base Modeling , 2010 .
[3] J. N. Yang,et al. Optimal Placement of Passive Dampers on Seismic and Wind-Excited Buildings using Combinatorial Optimization , 1999 .
[4] Yl L. Xu,et al. Closed‐form solution for seismic response of adjacent buildings with linear quadratic Gaussian controllers , 2002 .
[5] Jm M. Ko,et al. Experimental investigation of adjacent buildings connected by fluid damper , 1999 .
[6] S. M. Dumne,et al. Seismic response analysis of adjacent buildings connected with MR dampers , 2010 .
[7] R. S. Jangid,et al. Seismic analysis of structures connected with friction dampers , 2006 .
[8] J. Douglas Faires,et al. Numerical Analysis , 1981 .
[9] R. S. Jangid,et al. Seismic Response of Adjacent Buildings Connected with Friction Dampers , 2006 .
[10] Michael Vose. The simple genetic algorithm: foundations and theory (complex adaptive systems) , 1999 .
[11] Mahendra P. Singh,et al. Optimal placement of dampers for passive response control , 2002 .
[12] Yi-Qing Ni,et al. Stochastic optimal coupling-control of adjacent building structures , 2003 .
[13] Yl L. Xu,et al. Experimental Seismic Study of Adjacent Buildings with Fluid Dampers , 2003 .
[14] Hengjia Zhu,et al. Optimum connecting dampers to reduce the seismic responses of parallel structures , 2011 .
[15] M. De Angelis,et al. Optimal passive control of adjacent structures interconnected with nonlinear hysteretic devices , 2007 .
[16] R. S. Jangid,et al. Seismic response of dynamically similar adjacent structures connected with viscous dampers , 2010 .
[17] Jorge J. Moré,et al. Digital Object Identifier (DOI) 10.1007/s101070100263 , 2001 .
[18] Hengjia Zhu,et al. Optimum parameters of Maxwell model-defined dampers used to link adjacent structures , 2005 .
[19] Yoyong Arfiadi,et al. Optimum Design of Absorber for MDOF Structures , 1998 .
[20] W. S. Zhang,et al. VIBRATION ANALYSIS OF TWO BUILDINGS LINKED BY MAXWELL MODEL-DEFINED FLUID DAMPERS , 2000 .
[21] Wl L. Qu,et al. Semi‐active control of seismic response of tall buildings with podium structure using ER/MR dampers , 2001 .
[22] You-Lin Xu,et al. Seismic response control of a building complex utilizing passive friction damper: experimental investigation , 2006 .
[23] The use of optimization procedures in tuning vibration dampers , 2002 .
[24] M. De Angelis,et al. A reduced order model for optimal design of 2-mdof adjacent structures connected by hysteretic dampers , 2007 .
[25] M. F. Golnaraghi,et al. Optimal design of passive linear suspension using genetic algorithm , 2004 .
[26] J. Enrique Luco,et al. Optimal damping between two adjacent elastic structures , 1998 .
[27] Seung-Yong Ok,et al. Optimal design of hysteretic dampers connecting adjacent structures using multi-objective genetic algorithm and stochastic linearization method , 2008 .
[28] Yl L. Xu,et al. Dynamic characteristics and seismic response of adjacent buildings linked by discrete dampers , 1999 .
[29] Yl L. Xu,et al. Dynamic response of damper-connected adjacent buildings under earthquake excitation , 1999 .
[30] J. Miller. Numerical Analysis , 1966, Nature.