Comparison of dual-syringe and syringeless power injectors in outpatient MDCT practice: impact on the operator's performance, CT workflow, and operation cost.

PURPOSE The purpose of this study was to compare enhancement quality, performance efficiency, technologists' satisfaction, and operation costs between 2 different power injectors (PIs) in an outpatient setting. METHODS In this prospective study, 275 consecutive outpatients (135 men, 140 women) scheduled for contrast-enhanced CT (CECT) were randomized and scanned using either of 2 multidetector CT scanners (16 adjacently placed detectors) fitted with a dual-syringe contrast injector or a syringeless contrast injector. The corresponding CECT studies were subjectively reviewed by 2 radiologists in consensus to rate the quality of contrast enhancement in each study. The equipment preparation time (contrast media [CM], saline loading), releasing time (unloading of saline and CM), and CM wastage incurred for each PI were recorded by one operator. Technologists' satisfaction with the use of the PIs was rated on a 10-point scale. Statistical analyses were performed using Student's t tests. RESULTS A total of 140 patients were examined using the dual-syringe system, and 135 with the syringeless system, and CECT examination quality was comparable for both PI systems (P > .05). Equipment preparation time and releasing time per examination for dual-syringe and syringeless PIs were 139 ± 39 and 32 ± 14 seconds and 48 ± 31 and 8 ± 3 seconds, respectively (P < .001). On average, 11 mL CM wastage per examination was observed with the dual-syringe PI and 0 mL with the syringeless PI (P < .001). Technologists had higher satisfaction with the syringeless PI than the dual-syringe system (9.3 vs 6.3, P < .01). Because of improved efficiency, 2.6 additional patients per day were examined in the room using the syringeless PI. CONCLUSION Given comparable CECT examination quality, the syringeless PI was more user-friendly and improved outpatient CT workflow and CT throughput while allowing 11-mL CM saving per examination compared with the dual-syringe injector.

[1]  J. Broder,et al.  ALARA : BUILDING BRIDGES BETWEEN RADIOLOGY AND EMERGENCY MEDICINE CT utilization : the emergency department perspective , 2008 .

[2]  S. Saini,et al.  Effect of multislice CT technology on scanner productivity. , 2001, AJR. American journal of roentgenology.

[3]  G. Gazelle,et al.  Diagnostic imaging costs: are they driving up the costs of hospital care? , 2005, Radiology.

[4]  A. Moss,et al.  Use of a Power Injector During Dynamic Computed Tomography , 1986, Journal of computer assisted tomography.

[5]  J. F. Rasmussen,et al.  Safe use of an intravenous power injector for CT: experience and protocol. , 1990, Radiology.

[6]  Sneha Soni,et al.  Reimbursement trends for outpatient interventional radiology procedures: comparison of hospital and freestanding physician office sites of service. , 2009, Journal of the American College of Radiology.

[7]  D. Sahani,et al.  Multidetector-row CT: economics and workflow , 2005, European radiology.

[8]  David M. Warshauer,et al.  Increasing utilization of computed tomography in the adult emergency department, 2000–2005 , 2006, Emergency Radiology.

[9]  J. W. Moser The deficit reduction act of 2005: policy, politics, and impact on radiologists. , 2006, Journal of the American College of Radiology : JACR.

[10]  R C Nelson,et al.  Extravasation detection accessory: clinical evaluation in 500 patients. , 1999, Radiology.

[11]  Mythreyi Bhargavan,et al.  Utilization of radiology services in the United States: levels and trends in modalities, regions, and populations. , 2005, Radiology.

[12]  R W Günther,et al.  Reduction of contrast material dose and artifacts by a saline flush using a double power injector in helical CT of the thorax. , 2000, AJR. American journal of roentgenology.

[13]  Andoni P. Toms,et al.  Requests for body computed tomography: increasing workload, increasing indications and increasing age , 2001, European Radiology.

[14]  S. Saini,et al.  Technical cost of CT examinations. , 2001, Radiology.

[15]  R. Nelson,et al.  Contrast media extravasation during dynamic CT: detection with an extravasation detection accessory. , 1998, Radiology.

[16]  Mythreyi Bhargavan,et al.  Workload of radiologists in the United States in 2002-2003 and trends since 1991-1992. , 2005, Radiology.

[17]  D. Hastreiter,et al.  2007 survey of radiologists: source of income and impact of the Deficit Reduction Act of 2005. , 2009, Journal of the American College of Radiology : JACR.

[18]  J. Broder,et al.  Increasing Utilization of Computed Tomography in the Pediatric Emergency Department, 2000-2006 , 2007 .

[19]  G. Boland,et al.  Enhancing CT productivity: strategies for increasing capacity. , 2008, AJR. American journal of roentgenology.

[20]  Jonathan H Sunshine,et al.  Nationwide trends in rates of utilization of noninvasive diagnostic imaging among the Medicare population between 1993 and 1999. , 2003, Radiology.