A novel method for voltage sag / swell compensation using Dynamic Voltage Restorer

This paper presents the design of Load side compensation topology of Dynamic Voltage Restorer using Z-source Inverter which is able to compensate voltage sag and swell at sensitive load terminals. Based on this topology, the DVR consists of uncontrolled rectifier for giving DC supply to Z-Source converter through DC link. Z- Source Converter based topology is proposed in order to enhance the voltage restoration property of the device. By controlling the shoot through capability of ZSC system using IGBTs provide ride-through capability during voltage sag, swell and provides high reliability. Additionally, a control scheme called Hysteresis Voltage loop controller is proposed to synthesis the desired injecting voltage. The simulation results are presented to demonstrate the effectiveness of the proposed DVR system, which exhibits the compensation for voltage sag and swell.

[1]  Math Bollen,et al.  Understanding Power Quality Problems , 1999 .

[2]  Il-Yop Chung,et al.  The DC link energy control method in dynamic voltage restorer system , 2003 .

[3]  S. Rama Reddy,et al.  Voltage sag/swell compensation using Z-Source inverter based dynamic voltage restorer , 2011, 2011 International Conference on Emerging Trends in Electrical and Computer Technology.

[4]  N.A. Rahim,et al.  Modeling and simulation for voltage sags/swells mitigation using dynamic voltage restorer (DVR) , 2008, 2008 Australasian Universities Power Engineering Conference.

[5]  A. Ghosh,et al.  Design of a capacitor-supported dynamic voltage restorer (DVR) for unbalanced and distorted loads , 2004, IEEE Transactions on Power Delivery.

[6]  Frede Blaabjerg,et al.  A Robust Control Scheme for Medium-Voltage-Level DVR Implementation , 2007, IEEE Transactions on Industrial Electronics.

[7]  P.C. Loh,et al.  Voltage Sag Compensation With Z-Source Inverter Based Dynamic Voltage Restorer , 2006, Conference Record of the 2006 IEEE Industry Applications Conference Forty-First IAS Annual Meeting.

[8]  H. Fujita,et al.  Design and Experimentation of a Dynamic Voltage Restorer Capable of Significantly Reducing an Energy-Storage Element , 2008, IEEE Transactions on Industry Applications.

[9]  L. Morgan,et al.  Experience with an inverter-based dynamic voltage restorer , 1999 .

[10]  F.A.L. Jowder,et al.  Design and analysis of dynamic voltage restorer for deep voltage sag and harmonic compensation , 2009 .

[11]  Fang Zheng Peng Z-source inverter , 2002 .

[12]  B. Justus Rabi,et al.  Harmonics Study and Comparison of Z-source Inverter with Traditional Inverters , 2005 .

[13]  Mike Barnes,et al.  Voltage sag detection technique for a dynamic voltage restorer , 2002 .