Artifacts associated with MR neuroangiography.

Neurovascular MR angiography (MRA) is rapidly gaining greater clinical acceptance. To provide functional information, novel techniques of acquisition, information processing, and display are used, generating a new set of artifacts. The purpose of this paper is to outline the causes, provide examples, and note clinical problems associated with MRA artifacts by grouping them into six common types: 1) poor visualization of small vessels, 2) overestimation of stenosis, 3) view-to-view variations, 4) false positives, 5) false negatives, and 6) vessel overlap. This in turn will lead to four generalized solutions: 1) optimize acquisition parameters, 2) edit volume boundaries before performing maximum intensity projection reconstructions, 3) refer to the individual source images, and 4) use alternative image processing. By organizing and simplifying both clinical problems and solutions into major categories, a greater understanding of the current clinical indications and the overall goals of MRA can be achieved.

[1]  K. Parker,et al.  Mechanics and imaging of the macrocirculation , 1990, Magnetic resonance in medicine.

[2]  G Laub,et al.  Displays for MR angiography , 1990, Magnetic resonance in medicine.

[3]  S. Souza,et al.  Three-dimensional phase-contrast MR angiography in the head and neck: preliminary report. , 1990, AJR. American journal of roentgenology.

[4]  E M Haacke,et al.  Optimizing blood vessel contrast in fast three‐dimensional MRI , 1990, Magnetic resonance in medicine.

[5]  E M Haacke,et al.  In-plane vascular imaging: pulse sequence design and strategy. , 1988, Radiology.

[6]  H E Cline,et al.  Three‐dimensional time‐of‐flight magnetic resonance angiography using spin saturation , 1989, Magnetic resonance in medicine.

[7]  R R Edelman,et al.  Intracerebral arteriovenous malformations: evaluation with selective MR angiography and venography. , 1989, Radiology.

[8]  F W Wehrli,et al.  Time‐of‐flight effects in MR imaging of flow , 1990, Magnetic resonance in medicine.

[9]  L. Hedlund,et al.  Evaluation of flow through simulated vascular stenoses with gradient echo magnetic resonance imaging. , 1989, Investigative radiology.

[10]  P. J. Keller,et al.  MR angiography with two-dimensional acquisition and three-dimensional display. Work in progress. , 1989, Radiology.

[11]  K.,et al.  Blood flow imaging with MR: spin-phase phenomena. , 1985, Radiology.

[12]  R L Ehman,et al.  Flow artifact reduction in MRI: A review of the roles of gradient moment nulling and spatial presaturation , 1990, Magnetic resonance in medicine.

[13]  E M Haacke,et al.  Three-dimensional (volume) gradient-echo imaging of the carotid bifurcation: preliminary clinical experience. , 1989, Radiology.

[14]  N J Pelc,et al.  Dural sinus occlusion: evaluation with phase-sensitive gradient-echo MR imaging. , 1991, AJNR. American journal of neuroradiology.

[15]  C L Dumoulin,et al.  Three‐dimensional phase contrast angiography , 1989, Magnetic resonance in medicine.

[16]  H E Cline,et al.  Volume rendering and connectivity algorithms for MR angiography , 1991, Magnetic resonance in medicine.

[17]  G T Gullberg,et al.  MR vascular imaging with a fast gradient refocusing pulse sequence and reformatted images from transaxial sections. , 1987, Radiology.

[18]  D G Mitchell,et al.  Color Doppler imaging: principles, limitations, and artifacts. , 1990, Radiology.

[19]  D Saloner,et al.  Artifacts in maximum-intensity-projection display of MR angiograms. , 1990, AJR. American journal of roentgenology.

[20]  L Axel,et al.  MR flow imaging by velocity-compensated/uncompensated difference images. , 1987, Journal of computer assisted tomography.

[21]  M. Motomiya,et al.  Flow Patterns in the Human Carotid Artery Bifurcation , 1984, Stroke.

[22]  J. Tsuruda,et al.  MR evaluation of large intracranial aneurysms using cine low flip angle gradient-refocused imaging. , 1988, AJR. American journal of roentgenology.

[23]  T J Masaryk,et al.  3DFT MR angiography of the carotid bifurcation: potential and limitations as a screening examination. , 1991, Radiology.

[24]  R R Edelman,et al.  Cerebral venography with MR. , 1991, Radiology.

[25]  A L Baert,et al.  Intracranial vascular lesions: optimization and clinical evaluation of three-dimensional time-of-flight MR angiography. , 1990, Radiology.

[26]  J N Lee,et al.  Rapid MR imaging of blood flow with a phase-sensitive, limited-flip-angle, gradient recalled pulse sequence: preliminary experience. , 1990, Radiology.

[27]  W. Kaiser,et al.  MR Angiography with Gradient Motion Refocusing , 1988, Journal of computer assisted tomography.

[28]  J. Weinreb,et al.  Diagnosis of carotid artery stenosis: comparison of 2DFT time-of-flight MR angiography with contrast angiography in 50 patients. , 1991, AJNR. American journal of neuroradiology.

[29]  T J Masaryk,et al.  Intracranial circulation: pulse-sequence considerations in three-dimensional (volume) MR angiography. , 1989, Radiology.

[30]  J. Ross,et al.  Intracranial circulation: preliminary clinical results with three-dimensional (volume) MR angiography. , 1989, Radiology.

[31]  D. Yousem,et al.  Hyperintense thrombus on GRASS MR images: potential pitfall in flow evaluation. , 1990, AJNR. American journal of neuroradiology.

[32]  E. Haacke,et al.  Lumen definition in MR angiography , 1991, Journal of magnetic resonance imaging : JMRI.