Construction and Evaluation of a Versatile ${\hbox {CO}}_{2}$ Controlled Breath Collection Device

Breath gas analysis offers fascinating new opportunities as it is completely noninvasive and provides a unique window to various biochemical processes in the organism. Requirements for clinical application of this innovative technique include on site and point of care applicability. As most analytical methods like sensors are often not fast enough to realize breath-to-breath sampling additional effort is necessary to provide breath samples of well defined and reproducible composition. For that purpose, we built an automatic CO2 controlled device from standard industrial components that enables adjustable breath sampling in any phase of expiration. Control of sampling was realized by fast responding infrared CO2 sensors. The electrical signal of these sensors was used to trigger a micro pump and a valve. In order to render the device as versatile as possible direct coupling with sensors as well as continuous or discrete sampling via a sample loop or traps was possible. CO2 concentrations, gas flow, and sample volumes were continuously recorded. Reliability and reproducibility of the device were evaluated and compared with an already established and validated manual sampling method. Alveolar concentrations of selected volatile organic compounds (VOCs) were determined in the corresponding samples taken in rest and during treadmill exercise. Substance concentrations of breath biomarkers in the automatically and manually collected alveolar samples were identical. Reliable sampling was possible with the automatic device up to respiratory rates of 40/min. Controlled and versatile alveolar sampling represents an indispensable requirement of application of most analytical methods and sensor technology in breath analysis.

[1]  Bogusław Buszewski,et al.  Human exhaled air analytics: biomarkers of diseases. , 2007, Biomedical chromatography : BMC.

[2]  Klaus Geiger,et al.  Breath analysis in critically ill patients: potential and limitations , 2004, Expert review of molecular diagnostics.

[3]  M. Phillips,et al.  Variation in volatile organic compounds in the breath of normal humans. , 1999, Journal of chromatography. B, Biomedical sciences and applications.

[4]  T. Risby,et al.  Clinical application of breath biomarkers of oxidative stress status. , 1999, Free radical biology & medicine.

[5]  Wolfram Miekisch,et al.  From highly sophisticated analytical techniques to life-saving diagnostics: Technical developments in breath analysis , 2006 .

[6]  J Guttmann,et al.  CO(2)-controlled sampling of alveolar gas in mechanically ventilated patients. , 2001, Journal of applied physiology.

[7]  Sabine Kischkel,et al.  Impact of sampling procedures on the results of breath analysis , 2008, Journal of breath research.

[8]  W. Miekisch,et al.  Diagnostic potential of breath analysis--focus on volatile organic compounds. , 2004, Clinica chimica acta; international journal of clinical chemistry.

[9]  Tarek Mekhail,et al.  Diagnosis of lung cancer by the analysis of exhaled breath with a colorimetric sensor array , 2007, Thorax.

[10]  Josef Guttmann,et al.  CO2-controlled sampling of alveolar gas in mechanically ventilated patients , 2001 .

[11]  K Geiger,et al.  Impact of inspired substance concentrations on the results of breath analysis in mechanically ventilated patients , 2005, Biomarkers : biochemical indicators of exposure, response, and susceptibility to chemicals.

[12]  C L P Thomas,et al.  An adaptive breath sampler for use with human subjects with an impaired respiratory function. , 2007, The Analyst.

[13]  M. Phillips Method for the collection and assay of volatile organic compounds in breath. , 1997, Analytical biochemistry.

[14]  A. Manolis,et al.  The diagnostic potential of breath analysis. , 1983, Clinical chemistry.