Building blocks of a multi-layer PET with time sequence photon interaction discrimination and double Compton camera

Abstract Current PET detectors have a very low sensitivity, of the order of a few percent. One of the reasons is the fact that Compton interactions are rejected. If an event involves multiple Compton scattering and the total deposited energy lays within the photoelectric peak, then an energy-weighted centroid is the given output for the coordinates of the reconstructed interaction point. This introduces distortion in the final reconstructed image. The aim of our work is to prove that Compton events are a very rich source of additional information as one can improve the resolution of the detector and implicitly the final reconstructed image. This could be a real breakthrough for PET detector technology as one should be able to obtain better results with less patient radiation. Using a PET as a double Compton camera, by means of Compton cone matching i.e., Compton cones coming from the same event should be compatible, is applied to discard randoms, patient scattered events and also, to perform a correct matching among events with multiple coincidences. In order to fully benefit experimentally from Compton events using monolithic scintillators a multi-layer configuration is needed and a good time-of-flight resolution.

[1]  J. M. Nightingale,et al.  Gamma-radiation imaging system based on the Compton effect , 1977 .

[2]  P. Dorenbos,et al.  Scintillation properties of LaCl3:Ce3+ crystals: fast, efficient and high-energy-resolution scintillators , 2002 .

[3]  H. Malcolm Hudson,et al.  Accelerated image reconstruction using ordered subsets of projection data , 1994, IEEE Trans. Medical Imaging.

[4]  P. Dorenbos,et al.  X-ray and gamma-ray response of a 2″×2″ LaBr3:Ce scintillation detector , 2007 .

[5]  J. M. Nightingale,et al.  A proposed γ camera , 1974, Nature.

[6]  Benjamin Frisch,et al.  Time of flight positron emission tomography towards 100ps resolution with L(Y)SO: An experimental and theoretical analysis , 2013 .

[7]  Craig S Levin,et al.  Promising New Photon Detection Concepts for High-Resolution Clinical and Preclinical PET , 2012, The Journal of Nuclear Medicine.

[8]  Carlos Lacasta,et al.  Performance evaluation of MACACO: a multilayer Compton camera , 2017, Physics in medicine and biology.

[9]  A. Blondel,et al.  Time of flight positron emission tomography towards 100 ps resolution with L ( Y ) SO : an experimental and theoretical analysis , 2017 .

[10]  J. Benlloch,et al.  Implementation and analysis of list mode algorithm using tubes of response on a dedicated brain and breast PET , 2013 .

[11]  J. Sempau,et al.  A PENELOPE-based system for the automated Monte Carlo simulation of clinacs and voxelized geometries-application to far-from-axis fields. , 2011, Medical physics.

[12]  T. Budinger,et al.  PET instrumentation: what are the limits? , 1998, Seminars in nuclear medicine.

[13]  Yuxin Feng,et al.  Optimized geometry and limitations of compton cameras with LaBr3 , 2007, 2007 IEEE Nuclear Science Symposium Conference Record.

[14]  P. Lecoq,et al.  Pushing the Limits in Time-of-Flight PET Imaging , 2017, IEEE Transactions on Radiation and Plasma Medical Sciences.

[15]  Pablo Conde,et al.  Performance Study of a Large Monolithic LYSO PET Detector With Accurate Photon DOI Using Retroreflector Layers , 2017, IEEE Transactions on Radiation and Plasma Medical Sciences.

[16]  M. V. Nemallapudi,et al.  Sub-100 ps coincidence time resolution for positron emission tomography with LSO:Ce codoped with Ca , 2015, Physics in medicine and biology.

[17]  J. Sempau,et al.  Experimental benchmarks of the Monte Carlo code penelope , 2003 .

[18]  H. G. Jackson,et al.  High Resolution Computed Tomography of Positron Emitters , 1976, IEEE Transactions on Nuclear Science.

[19]  J. Sempau,et al.  PENELOPE-2006: A Code System for Monte Carlo Simulation of Electron and Photon Transport , 2009 .

[20]  F. Rademakers,et al.  ROOT — An object oriented data analysis framework , 1997 .

[21]  C Lartizien,et al.  GATE: a simulation toolkit for PET and SPECT. , 2004, Physics in medicine and biology.

[22]  M. McConnell,et al.  Instrument description and performance of the Imaging Gamma-Ray Telescope COMPTEL aboard the Compton Gamma-Ray Observatory , 1993 .

[23]  Gabriela Llosa,et al.  Performance improvement tests of MACACO: A Compton telescope based on continuous crystals and SiPMs , 2017, Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment.

[24]  Magdalena Rafecas,et al.  Second LaBr3 compton telescope prototype , 2013, 2013 3rd International Conference on Advancements in Nuclear Instrumentation, Measurement Methods and their Applications (ANIMMA).