Building blocks of a multi-layer PET with time sequence photon interaction discrimination and double Compton camera
暂无分享,去创建一个
Laura Moliner | V. Giménez-Alventosa | M. J. Rodriguez-Alvarez | Victor Ilisie | Filomeno Sanchez | Antonio J. Gonzalez | J. Benlloch | F. Sánchez | L. Moliner | M. Rodríguez-Álvarez | J. M. Benlloch | V. Ilisie | V. Giménez-Alventosa | Antonio J. González
[1] J. M. Nightingale,et al. Gamma-radiation imaging system based on the Compton effect , 1977 .
[2] P. Dorenbos,et al. Scintillation properties of LaCl3:Ce3+ crystals: fast, efficient and high-energy-resolution scintillators , 2002 .
[3] H. Malcolm Hudson,et al. Accelerated image reconstruction using ordered subsets of projection data , 1994, IEEE Trans. Medical Imaging.
[4] P. Dorenbos,et al. X-ray and gamma-ray response of a 2″×2″ LaBr3:Ce scintillation detector , 2007 .
[5] J. M. Nightingale,et al. A proposed γ camera , 1974, Nature.
[6] Benjamin Frisch,et al. Time of flight positron emission tomography towards 100ps resolution with L(Y)SO: An experimental and theoretical analysis , 2013 .
[7] Craig S Levin,et al. Promising New Photon Detection Concepts for High-Resolution Clinical and Preclinical PET , 2012, The Journal of Nuclear Medicine.
[8] Carlos Lacasta,et al. Performance evaluation of MACACO: a multilayer Compton camera , 2017, Physics in medicine and biology.
[9] A. Blondel,et al. Time of flight positron emission tomography towards 100 ps resolution with L ( Y ) SO : an experimental and theoretical analysis , 2017 .
[10] J. Benlloch,et al. Implementation and analysis of list mode algorithm using tubes of response on a dedicated brain and breast PET , 2013 .
[11] J. Sempau,et al. A PENELOPE-based system for the automated Monte Carlo simulation of clinacs and voxelized geometries-application to far-from-axis fields. , 2011, Medical physics.
[12] T. Budinger,et al. PET instrumentation: what are the limits? , 1998, Seminars in nuclear medicine.
[13] Yuxin Feng,et al. Optimized geometry and limitations of compton cameras with LaBr3 , 2007, 2007 IEEE Nuclear Science Symposium Conference Record.
[14] P. Lecoq,et al. Pushing the Limits in Time-of-Flight PET Imaging , 2017, IEEE Transactions on Radiation and Plasma Medical Sciences.
[15] Pablo Conde,et al. Performance Study of a Large Monolithic LYSO PET Detector With Accurate Photon DOI Using Retroreflector Layers , 2017, IEEE Transactions on Radiation and Plasma Medical Sciences.
[16] M. V. Nemallapudi,et al. Sub-100 ps coincidence time resolution for positron emission tomography with LSO:Ce codoped with Ca , 2015, Physics in medicine and biology.
[17] J. Sempau,et al. Experimental benchmarks of the Monte Carlo code penelope , 2003 .
[18] H. G. Jackson,et al. High Resolution Computed Tomography of Positron Emitters , 1976, IEEE Transactions on Nuclear Science.
[19] J. Sempau,et al. PENELOPE-2006: A Code System for Monte Carlo Simulation of Electron and Photon Transport , 2009 .
[20] F. Rademakers,et al. ROOT — An object oriented data analysis framework , 1997 .
[21] C Lartizien,et al. GATE: a simulation toolkit for PET and SPECT. , 2004, Physics in medicine and biology.
[22] M. McConnell,et al. Instrument description and performance of the Imaging Gamma-Ray Telescope COMPTEL aboard the Compton Gamma-Ray Observatory , 1993 .
[23] Gabriela Llosa,et al. Performance improvement tests of MACACO: A Compton telescope based on continuous crystals and SiPMs , 2017, Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment.
[24] Magdalena Rafecas,et al. Second LaBr3 compton telescope prototype , 2013, 2013 3rd International Conference on Advancements in Nuclear Instrumentation, Measurement Methods and their Applications (ANIMMA).