A Novel Neural-Network Model for Deriving Standard 12-Lead ECGs From Serial Three-Lead ECGs: Application to Self-Care

Synthesis of the 12-lead ECG has been investigated in the past decade as a method to improve patient monitoring in situations where the acquisition of the 12-lead ECG is cumbersome and time consuming. This paper presents and assesses a novel approach for deriving 12-lead ECGs from a pseudoorthogonal three-lead subset via generic and patient-specific nonlinear reconstruction methods based on the use of artificial neural-networks (ANNs) committees. We train and test the ANN on a set of serial ECGs from 120 cardiac inpatients from the intensive care unit of the Cardiology Hospital of Lyon. We then assess the similarity between the synthesized ECGs and the original ECGs at the quantitative level in comparison with generic and patient-specific multiple-regression-based methods. The ANN achieved accurate reconstruction of the 12-lead ECGs of the study population using both generic and patient-specific ANN transforms, showing significant improvements over generic (p -value ¿ 0.05) and patient-specific ( p-value ¿ 0.01) multiple-linear-regression-based models. Consequently, our neural-network-based approach has proven to be sufficiently accurate to be deployed in home care as well as in ambulatory situations to synthesize a standard 12-lead ECG from a reduced lead-set ECG recording.

[1]  Recommendations for measurement standards in quantitative electrocardiography. The CSE Working Party. , 1985, European heart journal.

[2]  Mattias Ohlsson,et al.  New paradigms in telemedicine: ambient intelligence, wearable, pervasive and personalized. , 2004, Studies in health technology and informatics.

[3]  J A Scherer,et al.  Synthesis of the 12-lead electrocardiogram from a 3-lead subset using patient-specific transformation vectors. An algorithmic approach to computerized signal synthesis. , 1989, Journal of electrocardiology.

[4]  Charles Maynard,et al.  Prehospital triage of acute myocardial infarction: wireless transmission of electrocardiograms to the on-call cardiologist via a handheld computer. , 2005, Journal of electrocardiology.

[5]  M. Kenward,et al.  An Introduction to the Bootstrap , 2007 .

[6]  Robert P. W. Duin,et al.  Learned from Neural Networks , 2000 .

[7]  P. Rubel,et al.  A neural network approach for patient-specific 12-lead ECG synthesis in patient monitoring environments , 2004, Computers in Cardiology, 2004.

[8]  Sankar K. Pal,et al.  Data mining in soft computing framework: a survey , 2002, IEEE Trans. Neural Networks.

[9]  Ljupco Hadzievski,et al.  A novel mobile transtelephonic system with synthesized 12-lead ECG , 2004, IEEE Transactions on Information Technology in Biomedicine.

[10]  Bernhard Pfeifer,et al.  Cardiac anisotropy: is it negligible regarding noninvasive activation time imaging? , 2006, IEEE Transactions on Biomedical Engineering.

[11]  R. Gulrajani The forward and inverse problems of electrocardiography. , 1998, IEEE engineering in medicine and biology magazine : the quarterly magazine of the Engineering in Medicine & Biology Society.

[12]  B. Drew,et al.  Accuracy of the EASI 12-lead electrocardiogram compared to the standard 12-lead electrocardiogram for diagnosing multiple cardiac abnormalities. , 1999, Journal of electrocardiology.

[13]  P Rubel,et al.  Methodology of ECG interpretation in the Lyon program. , 1990, Methods of information in medicine.

[14]  Fabrice Axisa,et al.  Flexible technologies and smart clothing for citizen medicine, home healthcare, and disease prevention , 2005, IEEE Transactions on Information Technology in Biomedicine.

[15]  Giandomenico Nollo,et al.  Toward personal eHealth in cardiology. Results from the EPI-MEDICS telemedicine project. , 2005, Journal of electrocardiology.