Optimization of Folch, Bligh-Dyer, and Matyash sample-to-extraction solvent ratios for human plasma-based lipidomics studies.

In order to profile the lipidome for untargeted lipidomics applications, analysis by ultra-high performance liquid chromatography - high resolution mass spectrometry (UHPLC-HRMS) typically requires the extraction of lipid content from sample matrices using matrix-specific conditions. The Folch, Bligh-Dyer, and Matyash extraction methods, while promising approaches, were originally tailored to specific matrices (brain tissue, fish muscle, and E. coli, respectively). Each of these methods have specific solvent ratios that must be adhered to achieve optimal extraction. Thus, the sample-to-solvent ratios for these methods should be optimized for the sample matrix of interest prior to employment. This study evaluated the appropriate sample-to-extraction solvent ratios for human plasma-based lipidomics studies. An advantage of employing biphasic lipid extractions is the ability to investigate both the aqueous and organic layers for increased analyte coverage in untargeted studies. Therefore, this work also evaluated the multi-omic capability of each lipid extraction method for plasma in an effort to provide a workflow capable of increasing analyte coverage in a single extraction, thus providing a more complete understanding of complex biological systems. In plasma, a decrease in sample-to-solvent ratios from 1:4, 1:10, 1:20, to 1:100 (v/v) resulted in a gradual increase in the peak area of a diverse range of metabolite (aqueous layer) and lipid (organic layer) species for each extraction method up to the 1:20(v/v) sample-to-solvent ratio. The Bligh-Dyer and Folch methods yielded the highest peak areas at every plasma sample-to-solvent ratios for both metabolite and lipid species. Depending on the lipid class of interest, the Folch or Bligh-Dyer method is best suited for analysis of human plasma at a 1:20 (v/v) sample to total solvent ratio.

[1]  G. Meer,et al.  Lipid Map of the Mammalian Cell , 2011 .

[2]  R. Yost,et al.  Comparison of blood plasma sample preparation methods for combined LC-MS lipidomics and metabolomics. , 2015, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.

[3]  Peter J Meikle,et al.  Zebrafish Embryonic Lipidomic Analysis Reveals that the Yolk Cell Is Metabolically Active in Processing Lipid. , 2016, Cell reports.

[4]  Alisa Rudnitskaya,et al.  A comparison of five lipid extraction solvent systems for lipidomic studies of human LDL[S] , 2013, Journal of Lipid Research.

[5]  Matthias M. Müller,et al.  Comparison of Different Procedures for the Lipid Extraction from HL-60 Cells: A MALDI-TOF Mass Spectrometric Study , 2005, Zeitschrift fur Naturforschung. C, Journal of biosciences.

[6]  E. M. Boyd THE EXTRACTION OF BLOOD LIPIDS , 1936 .

[7]  G. Theodoridis,et al.  Sample preparation prior to the LC-MS-based metabolomics/metabonomics of blood-derived samples. , 2011, Bioanalysis.

[8]  J. Folch,et al.  A simple method for the isolation and purification of total lipides from animal tissues. , 1957, The Journal of biological chemistry.

[9]  H. Brown,et al.  Lipidomics: a mass spectrometry based systems level analysis of cellular lipids. , 2009, Current opinion in chemical biology.

[10]  W. Christie PREPARATION OF LIPID EXTRACTS FROM TISSUES , 1993 .

[11]  Katja Dettmer,et al.  Metabolite extraction from adherently growing mammalian cells for metabolomics studies: optimization of harvesting and extraction protocols , 2011, Analytical and bioanalytical chemistry.

[12]  G. Halliday,et al.  An Improved High-Throughput Lipid Extraction Method for the Analysis of Human Brain Lipids , 2013, Lipids.

[13]  Jeremy P. Koelmel,et al.  LipidMatch: an automated workflow for rule-based lipid identification using untargeted high-resolution tandem mass spectrometry data , 2017, BMC Bioinformatics.

[14]  Sara J. Iverson,et al.  Comparison of the bligh and dyer and folch methods for total lipid determination in a broad range of marine tissue , 2001, Lipids.

[15]  W. J. Dyer,et al.  A rapid method of total lipid extraction and purification. , 1959, Canadian journal of biochemistry and physiology.

[16]  S. Kohlwein,et al.  A versatile ultra-high performance LC-MS method for lipid profiling , 2014, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.

[17]  Shanping Wang,et al.  Effect of (R)‐salbutamol on the switch of phenotype and metabolic pattern in LPS‐induced macrophage cells , 2019, Journal of cellular and molecular medicine.

[18]  Michael C. Thomas,et al.  A Lipidomic Approach to Understanding Free Fatty Acid Lipogenesis Derived from Dissolved Inorganic Carbon within Cnidarian-Dinoflagellate Symbiosis , 2012, PloS one.

[19]  T. Rupasinghe Lipidomics: extraction protocols for biological matrices. , 2013, Methods in molecular biology.

[20]  K. Kulp,et al.  Preparation of single cells for imaging/profiling mass spectrometry , 2008, Journal of the American Society for Mass Spectrometry.

[21]  C. Ulmer,et al.  A Robust Lipidomics Workflow for Mammalian Cells, Plasma, and Tissue Using Liquid-Chromatography High-Resolution Tandem Mass Spectrometry. , 2017, Methods in molecular biology.

[22]  V. Niggli,et al.  The Use of Organic Solvents in Membrane Research , 1977 .

[23]  D. Vuckovic,et al.  Systematic Assessment of Seven Solvent and Solid-Phase Extraction Methods for Metabolomics Analysis of Human Plasma by LC-MS , 2016, Scientific Reports.

[24]  Matej Oresic,et al.  MZmine 2: Modular framework for processing, visualizing, and analyzing mass spectrometry-based molecular profile data , 2010, BMC Bioinformatics.

[25]  G. Siuzdak,et al.  Solvent-dependent metabolite distribution, clustering, and protein extraction for serum profiling with mass spectrometry. , 2006, Analytical chemistry.

[26]  Z. Ouyang,et al.  Identification and quantitation of lipid C=C location isomers: A shotgun lipidomics approach enabled by photochemical reaction , 2016, Proceedings of the National Academy of Sciences.