A highly articulated robotic surgical system for minimally invasive surgery.

PURPOSE We developed a novel, highly articulated robotic surgical system (CardioARM) to enable minimally invasive intrapericardial therapeutic delivery through a subxiphoid approach. We performed preliminary proof of concept studies in a porcine preparation by performing epicardial ablation. DESCRIPTION CardioARM is a robotic surgical system having an articulated design to provide unlimited but controllable flexibility. The CardioARM consists of serially connected, rigid cyclindrical links housing flexible working ports through which catheter-based tools for therapy and imaging can be advanced. The CardioARM is controlled by a computer-driven, user interface, which is operated outside the operative field. EVALUATION In six experimental subjects, the CardioARM was introduced percutaneously through a subxiphoid access. A commercial 5-French radiofrequency ablation catheter was introduced through the working port, which was then used to guide deployment. In all subjects, regional ("linear") left atrial ablation was successfully achieved without complications. CONCLUSIONS Based on these preliminary studies, we believe that the CardioARM promises to enable deployment of a number of epicardium-based therapies. Improvements in imaging techniques will likely facilitate increasingly complex procedures.

[1]  Elia Biganzoli,et al.  Updated Worldwide Survey on the Methods, Efficacy, and Safety of Catheter Ablation for Human Atrial Fibrillation , 2005, Circulation. Arrhythmia and electrophysiology.

[2]  Marco A Zenati,et al.  Epicardial left ventricular mapping using subxiphoid video pericardioscopy. , 2007, The Annals of thoracic surgery.

[3]  N. Berlinger,et al.  Robotic surgery--squeezing into tight places. , 2006, The New England journal of medicine.

[4]  E. Sosa,et al.  Epicardial Mapping and Ablation Techniques to Control Ventricular Tachycardia , 2005, Journal of cardiovascular electrophysiology.

[5]  Douglas Packer,et al.  Worldwide Survey on the Methods, Efficacy, and Safety of Catheter Ablation for Human Atrial Fibrillation , 2005, Circulation.

[6]  Andrea Natale,et al.  Percutaneous Pericardial Instrumentation for Endo-Epicardial Mapping of Previously Failed Ablations , 2003, Circulation.

[7]  David Schwartzman,et al.  Left Heart Pacing Lead Implantation Using Subxiphoid Videopericardioscopy , 2003, Journal of cardiovascular electrophysiology.

[8]  Carlo Pappone,et al.  Pulmonary Vein Stenosis after Catheter Ablation for Atrial Fibrillation , 2003, Journal of cardiovascular electrophysiology.

[9]  D. Haines,et al.  Cerebrovascular Complication Associated with Pulmonary Vein Ablation , 2002, Journal of cardiovascular electrophysiology.

[10]  F. Morady Radio-frequency ablation as treatment for cardiac arrhythmias. , 1999, The New England journal of medicine.