A comparison of polymeric materials as pre-concentrating media for use with ATR/FTIR sensing

Polymer-modified ATR-FTIR spectroscopy was investigated to determine its potential suitability for use as an analytical methodology for process stream analysis. The process stream under investigation contains toluene, tetrahydrofuran, ethanol, and acetonitrile in an aqueous matrix. Four polymers, Teflon® AF2400, poly(acrylonitrile-co-butadiene) (PAB), polydimethylsiloxane (PDMS), and poly(styrene-co-butadiene) (PSB), were chosen for study based on partition coefficients measured using a novel automated GC technique. Polymer suitability as pre-concentration media was assessed utilizing analyte/polymer diffusion coefficient data, equilibrium absorbance values, water ingress, and polymer plasticization. PAB displayed the fastest sensing times and enhanced sensitivities. Teflon® AF2400 demonstrated a low water absorption and a low degree of plasticization. Other factors affecting the diffusion rate of analytes were also investigated including molecular size, shape and analyte concentration. This research demonstrated that the choice of pre-concentrating medium is not a trivial issue, being dictated by a combination of sensitivity constraints as well as polymer robustness in real sample matrices.

[1]  Sabu Thomas,et al.  Molecular transport of aromatic hydrocarbons through crosslinked styrene-butadiene rubber membranes , 1996 .

[2]  B. Mizaikoff,et al.  Simultaneous quantitative determination of benzene, toluene, and xylenes in water using mid-infrared evanescent field spectroscopy. , 2004, Analytical chemistry.

[3]  B. Mizaikoff,et al.  Sol-gel based mid-infrared evanescent wave sensors for detection of organophosphate pesticides in aqueous solution , 2003 .

[4]  Hugh Masterson,et al.  Determination of Hydrocarbons Using Sapphire Fibers Coated with Poly(Dimethylsiloxane) , 2003, Applied spectroscopy.

[5]  John Crank,et al.  Diffusion in polymers , 1968 .

[6]  B. Mizaikoff,et al.  Infrared fiber optic gas sensor for chlorofluorohydrocarbons , 1995 .

[7]  J. Feller,et al.  Evolution of electrical properties of some conductive polymer composite textiles with organic solvent vapours diffusion , 2004 .

[8]  L. Philippe,et al.  An FTIR/ATR in situ study of sorption and transport in corrosion protective organic coatings: Paper 2. The effects of temperature and isotopic dilution , 2004 .

[9]  B. Murphy,et al.  Investigation into polymer-diffusant interactions using ATR-FTIR spectroscopy , 2003 .

[10]  H. Naveau,et al.  ATR-FTIR sensor development for continuous on-line monitoring of chlorinated aliphatic hydrocarbons in a fixed-bed bioreactor. , 2000, Biotechnology and bioengineering.

[11]  Boris Mizaikoff,et al.  Selective polymer materials: absolute determination of their sorption properties , 2001, SPIE Optics East.

[12]  Rudolf Krska,et al.  Infrared attenuated total reflection spectroscopic investigations of the diffusion behaviour of chlorinated hydrocarbons into polymer membranes , 1995 .

[13]  H. B. Hopfenberg,et al.  Diffusion of organic vapors at low concentrations in glassy PVC, polystyrene, and PMMA , 1982 .

[14]  Measurement of the Rates of Diffusion of Halomethanes into Polymer Films Using ATR-FTIR Spectroscopy , 2003 .

[15]  J. L. Duda,et al.  Influence of swelling and diffusion-induced convection on polymer sorption processes , 2002 .

[16]  J. L. Duda,et al.  Free-volume equations for polymer-penetrant diffusion , 1989 .

[17]  Rudolf Krska,et al.  Investigation of Different Polymers as Coating Materials for IR/ATR Spectroscopic Trace Analysis of Chlorinated Hydrocarbons in Water , 1994 .

[18]  Abraham Katzir,et al.  Towards a remote IR fiber-optic sensor system for the determination of chlorinated hydrocarbons in water , 1997 .

[19]  Pierre Lochon,et al.  Permeability of block copolymers to vapors and liquids , 2002 .

[20]  Sabu Thomas,et al.  Transport of aromatic hydrocarbons through poly(ethylene-co-vinyl acetate) membranes , 1997 .

[21]  P. Lochon,et al.  Original structure–property relationships derived from a new modeling of diffusion of pure solvents through polymer membranes , 2004 .

[22]  Andrew G. Glen,et al.  APPL , 2001 .

[23]  A. Katzir,et al.  Sol-Gel-Coated Mid-Infrared Fiber-Optic Sensors , 2003, Applied spectroscopy.

[24]  Brian D. MacCraith,et al.  A study of the factors affecting the diffusion of chlorinated hydrocarbons into polyisobutylene and polyethylene-co-propylene for evanescent wave sensing , 2003 .

[25]  H. Steiner,et al.  Online sensing of volatile organic compounds in groundwater using mid-infrared fibre optic evanescent wave spectroscopy: a pilot scale test. , 2003, Water science and technology : a journal of the International Association on Water Pollution Research.

[26]  K. Flavin,et al.  Modelling of Fickian diffusion to enhance polymer-modified sensor performance , 2005 .

[27]  K. Peinemann,et al.  Effects of film thickness on density and gas permeation parameters of glassy polymers , 1996 .

[28]  C. Sammon,et al.  ATR-FTIR study of the diffusion and interaction of water and electrolyte solutions in polymeric membranes , 2002 .

[29]  James E. Walsh,et al.  Sensing of chlorinated hydrocarbons and pesticides in water using polymer coated mid-infrared optical fibres , 1996 .

[30]  Lloyd R. Snyder,et al.  Practical HPLC Method Development: Snyder/Practical , 1997 .

[31]  Peter McLoughlin,et al.  Determination of Chlorinated Hydrocarbon Species in Aqueous Solution Using Teflon Coated ATR Waveguide/FTIR Spectroscopy , 2003 .

[32]  James E. Walsh,et al.  Determination of pesticides in water using ATR-FTIR spectroscopy on PVC/chloroparaffin coatings , 1996 .

[33]  Sabu Thomas,et al.  Sorption and diffusion of methyl substituted benzenes through cross-linked nitrile rubber/poly(ethylene co-vinyl acetate) blend membranes , 2003 .

[34]  G. Unnikrishnan,et al.  Sorption and diffusion of aromatic hydrocarbons through filled natural rubber , 1996 .

[35]  Lloyd R. Snyder,et al.  Practical HPLC method development , 1988 .

[36]  Stephen R. Lowry,et al.  Polymer-Coated, Tapered Cylindrical ATR Elements for Sensitive Detection of Organic Solutes in Water , 1995 .

[37]  B. Murphy,et al.  Study of the impact of penetrant characteristics upon diffusion into Teflon membranes to further assess the performance of an ATR/FTIR sensor , 2003, Analytical and bioanalytical chemistry.

[38]  C. Deng,et al.  Vibrational spectroscopic studies of the dynamics and perturbation of water in polymeric films , 2002 .

[39]  J. Mielczarski,et al.  Infrared detection of chlorinated hydrocarbons in water at ppb levels of concentrations. , 2002, Water research.

[40]  Boris Mizaikoff,et al.  Mid-IR fiber-optic sensors. , 2003, Analytical chemistry.

[41]  J. S. Vrentas,et al.  Diffusion-controlled polymer dissolution and drug release , 2004 .

[42]  Paul Calvert,et al.  Diffusion in polymers , 1977, Nature.

[43]  Sabu Thomas,et al.  Molecular transport of aromatic solvents in isotactic polypropylene/ acrylonitrile-co-butadiene rubber blends , 2000 .

[44]  T. Barbari,et al.  The use of FTi.r.-a.t.r. spectroscopy to characterize penetrant diffusion in polymers , 1993 .

[45]  G. G. Stokes "J." , 1890, The New Yale Book of Quotations.