Assessment of inertial potential of variable-speed wind turbines

Variable-speed wind generators are decoupled from the grid frequency by their power electronic interfaces. These generators do not naturally exhibit inertial response or any other form of frequency support in generation deficit situations. This study assesses and quantifies the capability of wind turbines with doubly-fed induction generators for emulating the inertial response of conventional generators by providing temporary extra active power on top of the available production. Special attention is given to the underproduction phase that follows overproduction due to rotor speed recovery. Results show that the inertial contribution strongly depends on the wind turbine operating conditions and the allowed underproduction level.

[1]  J.M. Mauricio,et al.  Frequency Regulation Contribution Through Variable-Speed Wind Energy Conversion Systems , 2009, IEEE Transactions on Power Systems.

[2]  Jan Pierik,et al.  Inertial response of variable speed wind turbines , 2006 .

[3]  Geza Joos,et al.  Comparison of inertial response implementations in DFIG-based wind turbines , 2011, 2011 24th Canadian Conference on Electrical and Computer Engineering(CCECE).

[4]  H. Banakar,et al.  Kinetic Energy of Wind-Turbine Generators for System Frequency Support , 2009, IEEE Transactions on Power Systems.

[5]  H. Polinder,et al.  General Model for Representing Variable-Speed Wind Turbines in Power System Dynamics Simulations , 2002, IEEE Power Engineering Review.

[6]  S. Arnalte,et al.  Automatic Generation Control of a Wind Farm with Variable Speed Wind Turbines , 2002, IEEE Power Engineering Review.

[7]  M. Kayikci,et al.  Dynamic Contribution of DFIG-Based Wind Plants to System Frequency Disturbances , 2009, IEEE Transactions on Power Systems.

[8]  Siegfried Heier,et al.  Grid Integration of Wind Energy Conversion Systems , 1998 .

[9]  N. Jenkins,et al.  Comparison of the response of doubly fed and fixed-speed induction generator wind turbines to changes in network frequency , 2004, IEEE Transactions on Energy Conversion.

[10]  T. Thiringer,et al.  Temporary Primary Frequency Control Support by Variable Speed Wind Turbines— Potential and Applications , 2008, IEEE Transactions on Power Systems.

[11]  A. Mullane,et al.  Frequency control and wind turbine technologies , 2005, IEEE Transactions on Power Systems.

[12]  A. Mullane,et al.  An Assessment of the Impact of Wind Generation on System Frequency Control , 2010, IEEE Transactions on Power Systems.