Tibial Component Fixation With Cement: Full- Versus Surface-Cementation Techniques

Despite excellent outcomes with cemented tibial components in total knee arthroplasty, it still is debated whether the tibial stem should be cemented and what the optimal tibial stem design should be. Proponents of full cementation of the tibial stem and component state that better short-term and long-term component fixation is achieved when full cementation is used. Advocates for surface cementation contend that sufficient implant stability is achieved without the increased bone loss that occurs at revision and the stress shielding thought to be linked with cemented stems. This biomechanical cadaver study compared initial fixation and cement penetration depth in fully cemented versus surface cemented tibial trays with two different stem geometries (cruciate and I-beam) and compared two stem designs (cruciate and I-beam) fixed with surface cementation. Under an eccentric load, simulating three times body weight for 6000 cycles, there seems to be no difference in the micromotion of either tibial component implanted with surface or full cementation. Additionally, no difference in the average depth of cement penetration was detected between fixation techniques or stem types. The initial fixation stability of the surface cement technique seems correlated to the depth of cement penetration into proximal tibial surface. The current data support other studies which indicate that stability of surface-cemented tibial components may be related to the depth of cement penetration.

[1]  Chun‐Hsiung Huang,et al.  Long-term results of total condylar knee arthroplasty. , 2005, The Journal of arthroplasty.

[2]  R. D. Wills,et al.  The effect of tibial stem design on component micromotion in knee arthroplasty. , 1997, Clinical orthopaedics and related research.

[3]  G. Scuderi**,et al.  Survivorship of cemented total knee arthroplasty. , 1997, Clinical orthopaedics and related research.

[4]  K. Vince Fixation for primary total knee arthroplasty: cemented. , 1996, The Journal of arthroplasty.

[5]  T. Hearn,et al.  Micromotion secondary to axial, torsional, and shear loads in two models of cementless tibial components. , 1995, The Journal of arthroplasty.

[6]  S. Stern,et al.  Cemented total knee arthroplasty for gonarthrosis in patients 55 years old or younger. , 1990, Clinical orthopaedics and related research.

[7]  L. Whiteside,et al.  Effects of screws and a sleeve on initial fixation in uncemented total knee tibial components. , 1990, Clinical orthopaedics and related research.

[8]  P S Walker,et al.  A comparative study of uncemented tibial components. , 1990, The Journal of arthroplasty.

[9]  R. E. Sherman,et al.  Stability of initial fixation of the tibial component in cementless total knee arthroplasty , 1990, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[10]  Ranawat Cs,et al.  Effect of posterior cruciate sacrifice on durability of the cement-bone interface. A nine-year survivorship study of 100 total condylar knee arthroplasties. , 1989 .

[11]  P S Walker,et al.  Tibial Component Fixation in Deficient Tibial Bone Stock , 1984, Clinical orthopaedics and related research.

[12]  M. Ritter,et al.  The Herbert total knee replacement: a longer than three year follow-up. , 1977, Clinical orthopaedics and related research.

[13]  W. Enneking,et al.  Biomechanical properties of paired canine fibulas. , 1972, Journal of biomechanics.

[14]  S. White,et al.  The effect of central stem and stem length on micromovement of the tibial tray. , 1992, The Journal of arthroplasty.

[15]  J. Galante,et al.  A comparison of cemented and cementless fixation with the Miller-Galante total knee arthroplasty. , 1989, The Orthopedic clinics of North America.

[16]  D R Pedersen,et al.  An analysis of tibial component design in total knee arthroplasty. , 1983, Journal of biomechanics.

[17]  J B Morrison,et al.  The mechanics of the knee joint in relation to normal walking. , 1970, Journal of biomechanics.