Skin and proximity effects in the conductors of split gradient coils for a hybrid Linac-MRI scanner.

[1]  A. Kameari Transient eddy current analysis on thin conductors with arbitrary connections and shapes , 1981 .

[2]  R. Turner Minimum inductance coils , 1988 .

[3]  R. Bowtell,et al.  Gradient coil design using active magnetic screening , 1991, Magnetic resonance in medicine.

[4]  C. Boesch,et al.  Temporal and spatial analysis of fields generated by eddy currents in superconducting magnets: Optimization of corrections and quantitative characterization of magnet/gradient systems , 1991, Magnetic resonance in medicine.

[5]  S. Pissanetzky Minimum energy MRI gradient coils of general geometry , 1992 .

[6]  D. Doddrell,et al.  Gradient-Coil Design by Simulated Annealing , 1993 .

[7]  R. Turner,et al.  Gradient coil design: a review of methods. , 1993, Magnetic resonance imaging.

[8]  Roberto D. Graglia,et al.  On the numerical integration of the linear shape functions times the 3-D Green's function or its gradient on a plane triangle , 1993 .

[9]  Jianming Jin Electromagnetic Analysis and Design in Magnetic Resonance Imaging , 1998 .

[10]  Stuart Crozier,et al.  Determining complicated winding patterns for shim coils using stream functions and the target-field method , 2002 .

[11]  G. Peeren Stream function approach for determining optimal surface currents , 2003 .

[12]  J. M. B. Kroot,et al.  Eddy currents in a gradient coil, modeled as circular loops of strips , 2004, Proceedings. ICCEA 2004. 2004 3rd International Conference on Computational Electromagnetics and Its Applications, 2004..

[13]  Reinhold Ludwig,et al.  A Stream Function Method for Gradient Coil Design , 2005 .

[14]  A General Framework for Mixed Structured/Unstructured PEEC Modelling , 2008 .

[15]  Richard Bowtell,et al.  Novel gradient coils designed using a boundary element method , 2007 .

[16]  J. Kroot,et al.  Eddy currents in a transverse MRI gradient coil , 2008 .

[17]  Stuart Crozier,et al.  An improved equivalent magnetization current method applied to the design of local breast gradient coils. , 2009, Journal of magnetic resonance.

[18]  Feng Liu,et al.  Equivalent Magnetization Current Method Applied to the Design of Gradient Coils for Magnetic Resonance Imaging , 2009, IEEE Transactions on Magnetics.

[19]  Stuart Crozier,et al.  Minimax current density coil design , 2010, 1002.3413.

[20]  Roland Probst,et al.  Goodbye wires and formers: 3-D additive manufacturing and fractal cooling applied to construction of MRI gradient coils , 2011, 2011 IEEE Nuclear Science Symposium Conference Record.

[21]  Stuart Crozier,et al.  Simulation and analysis of the interactions between split gradient coils and a split magnet cryostat in an MRI-PET system. , 2012, Journal of magnetic resonance.

[22]  Stuart Crozier,et al.  Minimax current density gradient coils: Analysis of coil performance and heating , 2012, Magnetic resonance in medicine.

[23]  N. Shah,et al.  Theoretical design of gradient coils with minimum power dissipation: accounting for the discretization of current density into coil windings. , 2013, Journal of magnetic resonance.

[24]  Stuart Crozier,et al.  Flanged-edge transverse gradient coil design for a hybrid LINAC-MRI system. , 2013, Journal of magnetic resonance.

[25]  M. Repetto,et al.  Multilayer integral method for simulation of eddy currents in thin volumes of arbitrary geometry produced by MRI gradient coils , 2014, Magnetic resonance in medicine.