Quantitative measurement of wall shear rate by pulsed Doppler ultrasound.

A 20 MHz pulsed Doppler ultrasound system was used to obtain steady flow velocity profiles in cylindrical tubes. A deconvolution technique was employed to improve the spatial resolution and the corrected results were compared with Poiseuille's theory. Frequency domain windowing was used to suppress noise in the deconvolution procedure, using a method which reduced distortions at the window boundaries. Wall shear rate was calculated from the measured velocity profiles both before and after deconvolution, and compared with theory to quantify the accuracy of the technique. The results illustrate the significant improvement provided by deconvolution, with the average error in measured wall shear rate reducing from 46 to 12% after applying the technique. Some of the discrepancy is in part attributed to the method used to determine wall shear rate.

[1]  ROBERT M. NEREM,et al.  Velocity Distribution and Intimal Proliferation in Autologous Vein Grafts in Dogs , 1978, Circulation research.

[2]  P. Lafrance,et al.  Digital filters , 1974, Proceedings of the IEEE.

[3]  C. Miller,et al.  Transcutaneous measurement of blood velocity profiles and flow. , 1973, Cardiovascular research.

[4]  J. L. Garbini,et al.  An Analytical Procedure of Calibration for the Pulsed Ultrasonic Doppler Flow Meter , 1973 .

[5]  William H. Press,et al.  Numerical recipes , 1990 .

[6]  L. Sauvage,et al.  Current arterial prostheses. Experimental evaluation by implantation in the carotid and circumflex coronary arteries of the dog. , 1979, Archives of surgery.

[7]  Robert W. Ramirez,et al.  The Fft, Fundamentals and Concepts , 1984 .

[8]  Andrew R. Walker,et al.  Evaluating doppler devices using a moving string test target , 1982, Journal of clinical ultrasound : JCU.

[9]  朝倉 利光 R. B. Blackman and J. W. Tukey: The Measurement of Power Spectra, Dover Publications, Inc., New York, 1958, 208頁, 13.5×16cm, $1.85 , 1964 .

[10]  K. Morinaga,et al.  Effect of wall shear stress on intimal thickening of arterially transplanted autogenous veins in dogs. , 1985, Journal of vascular surgery.

[11]  D R Pedersen,et al.  Some characteristics of laminar flow velocity spectra detected by a 20 MHz pulsed ultrasound Doppler. , 1985, Journal of biomechanics.

[12]  M. G. Taylor,et al.  Directional Doppler techniques for detection of blood velocities. , 1976, Ultrasound in medicine & biology.

[13]  Hughes Pe The hydrodynamics of arterial prostheses. , 1991 .

[14]  Thien How,et al.  Attenuation of flow disturbances in tapered arterial grafts. , 1989, Journal of biomechanical engineering.

[15]  J. Wolfe,et al.  Experimental evidence to support the use of interposition vein collars/patches in distal PTFE anastomoses. , 1990, European journal of vascular surgery.

[16]  S. A. Ahmed,et al.  Velocity measurements in steady flow through axisymmetric stenoses at moderate Reynolds numbers. , 1983, Journal of biomechanics.

[17]  H. Schlichting Boundary Layer Theory , 1955 .

[18]  R. Black,et al.  Pulsed Doppler ultrasound system for the measurement of velocity distributions and flow disturbances in arterial prostheses. , 1989, Journal of biomedical engineering.

[19]  J. S. Cole,et al.  An ultrasonic pulsed Doppler system for measuring blood flow in small vessels. , 1974, Journal of applied physiology.

[20]  D. Giddens,et al.  Steady flow in a model of the human carotid bifurcation. Part II--laser-Doppler anemometer measurements. , 1982, Journal of biomechanics.

[21]  C. Zarins,et al.  Carotid Bifurcation Atherosclerosis: Quantitative Correlation of Plaque Localization with Flow Velocity Profiles and Wall Shear Stress , 1983, Circulation research.