Time-Frequency-Based Instantaneous Power Components for Transient Disturbances According to IEEE Standard 1459

IEEE Standard 1459 defines the power components based on the fast Fourier series. However, Fourier series assumes the signal is periodic in nature, and provides erroneous assessment of the power components in the presence of transient signals. Therefore, a new method is proposed for the evaluation of the IEEE Standard 1459 power components based on the time-frequency distribution (TFD) and the cross time-frequency distribution (XTFD) of transient signals. The TFD and XTFD preserve simultaneous time and variable frequency information of transient signals, and estimate the instantaneous power components according to IEEE Standard 1459. Results of computer simulated and real-world power quality disturbance case studies justify the effectiveness of the proposed method for the assessment of instantaneous power components under transient conditions.

[1]  Zbigniew Leonowicz,et al.  Measurement of IEC Groups and Subgroups using Advanced Spectrum Estimation Methods , 2006, IMTC 2006.

[2]  S. N. Singh,et al.  An Adaptive Time-Efficient Technique for Harmonic Estimation of Nonstationary Signals , 2013, IEEE Transactions on Industrial Electronics.

[3]  S. N. Singh,et al.  Fast Harmonic Estimation of Stationary and Time-Varying Signals Using EA-AWNN , 2013, IEEE Transactions on Instrumentation and Measurement.

[4]  A. Cataliotti,et al.  A Time-Domain Strategy for the Measurement of IEEE Standard 1459-2000 Power Quantities in Nonsinusoidal Three-Phase and Single-Phase Systems , 2008, IEEE Transactions on Power Delivery.

[5]  Liuchen Chang,et al.  Wavelet-Based Reactive Power and Energy Measurement in the Presence of Power Quality Disturbances , 2011, IEEE Transactions on Power Systems.

[6]  Miodrag D. Kusljevic,et al.  An Adaptive Resonator-Based Method for Power Measurements According to the IEEE Trial-Use Standard 1459–2000 , 2010, IEEE Transactions on Instrumentation and Measurement.

[7]  H. Lin Intelligent Neural Network-Based Fast Power System Harmonic Detection , 2007, IEEE Transactions on Industrial Electronics.

[8]  Guido Carpinelli,et al.  Adaptive Prony method for waveform distortion detection in power systems , 2007 .

[9]  Gary W. Chang,et al.  A two-stage ADALINE for harmonics and interharmonics measurement , 2010, 2010 5th IEEE Conference on Industrial Electronics and Applications.

[10]  G.W. Chang,et al.  Extended Real Model of Kalman Filter for Time-Varying Harmonics Estimation , 2010, IEEE Transactions on Power Delivery.

[11]  Walid Morsi,et al.  A new perspective for the IEEE standard 1459-2000 via stationary wavelet transform in the presence of nonstationary power quality disturbance , 2009, 2009 IEEE Power & Energy Society General Meeting.

[12]  A.R. Abdullah,et al.  Power quality analysis using linear time-frequency distribution , 2008, 2008 IEEE 2nd International Power and Energy Conference.

[13]  A. Cataliotti,et al.  A New Measurement Method for the Detection of Harmonic Sources in Power Systems Based on the Approach of the IEEE Std. 1459–2000 , 2010, IEEE Transactions on Power Delivery.

[14]  Zhenyu Guo,et al.  The time-frequency distributions of nonstationary signals based on a Bessel kernel , 1994, IEEE Trans. Signal Process..

[15]  Cheng-I Chen,et al.  Radial-Basis-Function-Based Neural Network for Harmonic Detection , 2010, IEEE Transactions on Industrial Electronics.

[16]  M. El-Hawary,et al.  Reformulating Power Components Definitions Contained in the IEEE Standard 1459-2000 Using Discrete Wavelet Transform , 2007, 2007 IEEE Power Engineering Society General Meeting.

[17]  S. N. Singh,et al.  Exact Model Order ESPRIT Technique for Harmonics and Interharmonics Estimation , 2012, IEEE Transactions on Instrumentation and Measurement.

[18]  M.E. El-Hawary,et al.  Wavelet Packet Transform-Based Power Quality Indices for Balanced and Unbalanced Three-Phase Systems Under Stationary or Nonstationary Operating Conditions , 2009, IEEE Transactions on Power Delivery.

[19]  M. Grady,et al.  Power quality indices for transient disturbances , 2006, 2006 IEEE Power Engineering Society General Meeting.

[20]  Math Bollen,et al.  A new joint sliding-window ESPRIT and DFT scheme for waveform distortion assessment in power systems , 2012 .

[21]  T. Thayaparan Time-Frequency Signal Analysis , 2014 .

[22]  M.H.J. Bollen,et al.  Estimating Interharmonics by Using Sliding-Window ESPRIT , 2008, IEEE Transactions on Power Delivery.

[23]  Mj Martin Bastiaans Time-frequency signal analysis , 2008 .

[24]  Jechang Jeong,et al.  Kernel design for reduced interference distributions , 1992, IEEE Trans. Signal Process..

[25]  A. Pigazo,et al.  Accurate and Computationally Efficient Implementation of the IEEE 1459-2000 Standard in Three-Phase Three-Wire Power Systems , 2007, IEEE Transactions on Power Delivery.

[26]  Yong-June Shin,et al.  Cross time-frequency distribution function , 2000, SPIE Optics + Photonics.

[27]  Kemal Leblebicioglu,et al.  Interharmonics analysis of power signals with fundamental frequency deviation using Kalman filtering , 2010 .

[28]  Alexander Eigeles Emanuel,et al.  Clarke's alpha, beta and zero components: a possible approach for the conceptual design of instrumentation compatible with IEEE std. 1459-2000 , 2004, Proceedings of the 21st IEEE Instrumentation and Measurement Technology Conference (IEEE Cat. No.04CH37510).

[29]  Johan Driesen,et al.  DSP implementation of power measurements according to the IEEE trial-use standard 1459 , 2004, IEEE Transactions on Instrumentation and Measurement.

[30]  M. El-Hawary,et al.  Reformulating Three-Phase Power Components Definitions Contained in the IEEE Standard 1459–2000 Using Discrete Wavelet Transform , 2007, IEEE Transactions on Power Delivery.