Multiband multi-echo simultaneous ASL/BOLD for task-induced functional MRI

Typical simultaneous blood oxygenation-level dependent (BOLD) and arterial spin labeling (ASL) sequences acquire two echoes, one perfusion-sensitive and one BOLD-sensitive. However, for ASL, spatial resolution and brain coverage are limited due to the T1 decay of the labeled blood. This study applies a sequence combining a multiband acquisition with four echoes for simultaneous BOLD and pseudo-continuous ASL (pCASL) echo planar imaging (MBME ASL/BOLD) for block-design task-fMRI. A multiband acceleration of four was employed to increase brain coverage and reduce slice-timing effects on the ASL signal. Multi-echo independent component analysis (MEICA) was implemented to automatically denoise the BOLD signal by regressing non-BOLD components. This technique led to increased temporal signal-to-noise ratio (tSNR) and BOLD sensitivity. The MEICA technique was also modified to denoise the ASL signal by regressing artifact and BOLD signals from the first echo time-series. The MBME ASL/BOLD sequence was applied to a finger-tapping task functional MRI (fMRI) experiment. Signal characteristics and activation were evaluated using single echo BOLD, combined ME BOLD, combined ME BOLD after MEICA denoising, perfusion-weighted (PW), and perfusion-weighted after MEICA denoising time-series. The PW data was extracted using both surround subtraction and high-pass filtering followed by demodulation. In addition, the CBF/BOLD response ratio and CBF/BOLD coupling were analyzed. Results showed that the MEICA denoising procedure significantly improved the BOLD signal, leading to increased BOLD sensitivity, tSNR, and activation statistics compared to conventional single echo BOLD data. At the same time, the denoised PW data showed increased tSNR and activation statistics compared to the non-denoised PW data. CBF/BOLD coupling was also increased using the denoised ASL and BOLD data. Our preliminary data suggest that the MBME ASL/BOLD sequence can be employed to collect whole-brain task-fMRI with improved data quality for both BOLD and PW time series, thus improving the results of block-design task fMRI.

[1]  J. Polimeni,et al.  Blipped‐controlled aliasing in parallel imaging for simultaneous multislice echo planar imaging with reduced g‐factor penalty , 2012, Magnetic resonance in medicine.

[2]  J. Hendrikse,et al.  Age‐related changes in brain hemodynamics; A calibrated MRI study , 2015, Human brain mapping.

[3]  G. Zaharchuk,et al.  Recommended implementation of arterial spin-labeled perfusion MRI for clinical applications: A consensus of the ISMRM perfusion study group and the European consortium for ASL in dementia. , 2015, Magnetic resonance in medicine.

[4]  J. Detre,et al.  A theoretical and experimental investigation of the tagging efficiency of pseudocontinuous arterial spin labeling , 2007, Magnetic resonance in medicine.

[5]  Greg Lee,et al.  Optimized simultaneous ASL and BOLD functional imaging of the whole brain , 2014, Journal of magnetic resonance imaging : JMRI.

[6]  Benedikt A. Poser,et al.  Investigating the benefits of multi-echo EPI for fMRI at 7 T , 2009, NeuroImage.

[7]  Thomas T. Liu,et al.  Cerebral blood flow and BOLD responses to a memory encoding task: A comparison between healthy young and elderly adults , 2007, NeuroImage.

[8]  Manus J Donahue,et al.  Dual echo vessel‐encoded ASL for simultaneous BOLD and CBF reactivity assessment in patients with ischemic cerebrovascular disease , 2015, Magnetic resonance in medicine.

[9]  Mark J. Lowe,et al.  Quantitative Comparison of Functional Contrast from BOLD-Weighted Spin-Echo and Gradient-Echo Echoplanar Imaging at 1.5 Tesla and H215O PET in the Whole Brain , 2000, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[10]  Wen-Ming Luh,et al.  Differentiating BOLD and non-BOLD signals in fMRI time series using multi-echo EPI , 2012, NeuroImage.

[11]  T. L. Davis,et al.  Calibrated functional MRI: mapping the dynamics of oxidative metabolism. , 1998, Proceedings of the National Academy of Sciences of the United States of America.

[12]  Noah D. Brenowitz,et al.  Integrated strategy for improving functional connectivity mapping using multiecho fMRI , 2013, Proceedings of the National Academy of Sciences.

[13]  Kevin Murphy,et al.  How long to scan? The relationship between fMRI temporal signal to noise ratio and necessary scan duration , 2007, NeuroImage.

[14]  R W Cox,et al.  AFNI: software for analysis and visualization of functional magnetic resonance neuroimages. , 1996, Computers and biomedical research, an international journal.

[15]  Thomas T. Liu,et al.  A signal processing model for arterial spin labeling functional MRI , 2005, NeuroImage.

[16]  Paul A. Taylor,et al.  FMRI Clustering in AFNI: False-Positive Rates Redux , 2017, Brain Connect..

[17]  G. Aguirre,et al.  Experimental Design and the Relative Sensitivity of BOLD and Perfusion fMRI , 2002, NeuroImage.

[18]  D. Norris,et al.  BOLD contrast sensitivity enhancement and artifact reduction with multiecho EPI: Parallel‐acquired inhomogeneity‐desensitized fMRI , 2006, Magnetic resonance in medicine.

[19]  Michael Brady,et al.  Improved Optimization for the Robust and Accurate Linear Registration and Motion Correction of Brain Images , 2002, NeuroImage.

[20]  Yi Wang,et al.  Simultaneous multi-slice Turbo-FLASH imaging with CAIPIRINHA for whole brain distortion-free pseudo-continuous arterial spin labeling at 3 and 7T , 2015, NeuroImage.

[21]  Sungho Tak,et al.  Associations of Resting-State fMRI Functional Connectivity with Flow-BOLD Coupling and Regional Vasculature , 2015, Brain Connect..

[22]  Amy J. Jak,et al.  Differential age effects on cerebral blood flow and BOLD response to encoding: Associations with cognition and stroke risk , 2009, Neurobiology of Aging.

[23]  R W Cox,et al.  Software tools for analysis and visualization of fMRI data , 1997, NMR in biomedicine.

[24]  Robin M Heidemann,et al.  Generalized autocalibrating partially parallel acquisitions (GRAPPA) , 2002, Magnetic resonance in medicine.

[25]  S. Posse,et al.  Enhancement of BOLD‐contrast sensitivity by single‐shot multi‐echo functional MR imaging , 1999, Magnetic resonance in medicine.

[26]  Michael A. Chappell,et al.  Effects of background suppression on the sensitivity of dual-echo arterial spin labeling MRI for BOLD and CBF signal changes , 2014, NeuroImage.

[27]  Society of magnetic resonance in medicine , 1990 .

[28]  Stefan Posse,et al.  Multi-echo acquisition , 2012, NeuroImage.

[29]  Ninon Burgos,et al.  New advances in the Clinica software platform for clinical neuroimaging studies , 2019 .

[30]  R. Buxton,et al.  Implementation of quantitative perfusion imaging techniques for functional brain mapping using pulsed arterial spin labeling , 1997, NMR in biomedicine.

[31]  D. Noll,et al.  Homodyne detection in magnetic resonance imaging. , 1991, IEEE transactions on medical imaging.

[32]  Jeff H. Duyn,et al.  Mapping resting-state functional connectivity using perfusion MRI , 2008, NeuroImage.

[33]  Hanzhang Lu,et al.  Detrimental effects of BOLD signal in arterial spin labeling fMRI at high field strength , 2006, Magnetic resonance in medicine.

[34]  Kawin Setsompop,et al.  Ultra-fast MRI of the human brain with simultaneous multi-slice imaging. , 2013, Journal of magnetic resonance.

[35]  Monique Ernst,et al.  Robust resting state fMRI processing for studies on typical brain development based on multi-echo EPI acquisition , 2014, Brain Imaging and Behavior.

[36]  Wanyong Shin,et al.  Whole brain perfusion measurements using arterial spin labeling with multiband acquisition , 2013, Magnetic resonance in medicine.

[37]  M. Corbetta,et al.  Resting interhemispheric functional magnetic resonance imaging connectivity predicts performance after stroke , 2009, Annals of neurology.

[38]  Sungho Tak,et al.  Dynamic and static contributions of the cerebrovasculature to the resting-state BOLD signal , 2014, NeuroImage.

[39]  David A Feinberg,et al.  Arterial spin labeling with simultaneous multi‐slice echo planar imaging , 2013, Magnetic resonance in medicine.

[40]  Carl D. Hacker,et al.  Clustering of Resting State Networks , 2012, PloS one.

[41]  P. Batchelor,et al.  International Society for Magnetic Resonance in Medicine , 1997 .

[42]  Andrew S. Nencka,et al.  Multiband multi-echo imaging of simultaneous oxygenation and flow timeseries for resting state connectivity , 2017, PloS one.

[43]  J. Detre,et al.  Cerebral perfusion and arterial transit time changes during task activation determined with continuous arterial spin labeling , 2000, Magnetic resonance in medicine.

[44]  D. Alsop,et al.  Continuous flow‐driven inversion for arterial spin labeling using pulsed radio frequency and gradient fields , 2008, Magnetic resonance in medicine.

[45]  Senhua Zhu,et al.  Resting State Brain Function Analysis Using Concurrent BOLD in ASL Perfusion fMRI , 2013, PloS one.

[46]  Steen Moeller,et al.  Multiband multislice GE‐EPI at 7 tesla, with 16‐fold acceleration using partial parallel imaging with application to high spatial and temporal whole‐brain fMRI , 2010, Magnetic resonance in medicine.

[47]  Silvina G. Horovitz,et al.  Separating slow BOLD from non-BOLD baseline drifts using multi-echo fMRI , 2015, NeuroImage.

[48]  Edward T. Bullmore,et al.  Differentiating BOLD and non-BOLD signals in fMRI time series from anesthetized rats using multi-echo EPI at 11.7T , 2014, NeuroImage.

[49]  Kevin Murphy,et al.  The absolute CBF response to activation is preserved during elevated perfusion: Implications for neurovascular coupling measures , 2016, NeuroImage.

[50]  Steen Moeller,et al.  Evaluation of highly accelerated simultaneous multi-slice EPI for fMRI , 2015, NeuroImage.