Aortic root sizing for transcatheter aortic valve implantation using a shape model parameterisation

During a transcatheter aortic valve implantation, an axisymmetric implant is placed in an irregularly shaped aortic root. Implanting an incorrect size can cause complications such as leakage of blood alongside or through the implant. The aim of this study was to construct a method that determines the optimal size of the implant based on the three-dimensional shape of the aortic root. Based on the pre-interventional computed tomography scan of 89 patients, a statistical shape model of their aortic root was constructed. The weights associated with the principal components and the volume of calcification in the aortic valve were used as parameters in a classification algorithm. The classification algorithm was trained using the patients with no or mild leakage after their intervention. Subsequently, the algorithms were applied to the patients with moderate to severe leakage. Cross validation showed that a random forest classifier assigned the same size in 65 ± 7% of the training cases, while 57 ± 8% of the patients with moderate to severe leakage were assigned a different size. This initial study showed that this semi-automatic method has the potential to correctly assign an implant size. Further research is required to assess whether the different size implants would improve the outcome of those patients.

[1]  Alec Vahanian,et al.  Determinants of significant paravalvular regurgitation after transcatheter aortic valve: implantation impact of device and annulus discongruence. , 2009, JACC. Cardiovascular interventions.

[2]  J. Dark,et al.  Aortic valve replacement in octogenarians , 2007, Journal of cardiothoracic surgery.

[3]  C. Lillehei,et al.  LEFT RETROGRADE CARDIOANGIOGRAPHY IN ACQUIRED CARDIAC DISEASE: TECHNIC, INDICATIONS AND INTERPRETATIONS IN 700 CASES. , 1964, The American journal of cardiology.

[4]  Hamid Behnam,et al.  Automatic Computation of Left Ventricular Volume Changes Over a Cardiac Cycle from Echocardiography Images by Nonlinear Dimensionality Reduction , 2015, Journal of Digital Imaging.

[5]  R. Baghaei OUTCOMES OF SURGICAL AORTIC VALVE REPLACEMENT IN HIGH-RISK PATIENTS: A MULTIINSTITUTIONAL STUDY , 2011 .

[6]  J. Leipsic,et al.  CT in transcatheter aortic valve replacement. , 2013, Radiology.

[7]  Jos Vander Sloten,et al.  Segmentation accuracy of long bones. , 2014, Medical engineering & physics.

[8]  Pablo Lamata,et al.  Myocardial Infarction Detection from Left Ventricular Shapes Using a Random Forest , 2015, STACOM@MICCAI.

[9]  Alejandro F. Frangi,et al.  A High-Resolution Atlas and Statistical Model of the Human Heart From Multislice CT , 2013, IEEE Transactions on Medical Imaging.

[10]  Renaud Keriven,et al.  Diffusion maps as a framework for shape modeling , 2011, Comput. Vis. Image Underst..

[11]  Juha Koikkalainen,et al.  Statistical shape model of atria, ventricles and epicardium from short- and long-axis MR images , 2004, Medical Image Anal..

[12]  J. Reiber,et al.  Ventricular shape biomarkers for Alzheimer's disease in clinical MR images , 2008, Magnetic resonance in medicine.

[13]  Susheel Kodali,et al.  Two-Year Outcomes After Transcatheter or Surgical Aortic Valve Replacement , 2013 .

[14]  Antonio Colombo,et al.  Computed tomography-based evaluation of aortic annulus, prosthesis size and impact on early residual aortic regurgitation after transcatheter aortic valve implantation. , 2013, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[15]  Alejandro F. Frangi,et al.  Joint Clustering and Component Analysis of Spatio-Temporal Shape Patterns in Myocardial Infarction , 2015, STACOM@MICCAI.

[16]  Cristian Lorenz,et al.  A comprehensive shape model of the heart , 2006, Medical Image Anal..

[17]  Jan Sijbers,et al.  Evaluation of an anthropometric shape model of the human scalp. , 2015, Applied ergonomics.

[18]  Nadia Magnenat-Thalmann,et al.  Automatic modeling of virtual humans and body clothing , 2004, Journal of Computer Science and Technology.

[19]  Maxime Sermesant,et al.  A statistical shape modelling framework to extract 3D shape biomarkers from medical imaging data: assessing arch morphology of repaired coarctation of the aorta , 2016, BMC Medical Imaging.

[20]  Adriaan Moelker,et al.  Three dimensional evaluation of the aortic annulus using multislice computer tomography: are manufacturer's guidelines for sizing for percutaneous aortic valve replacement helpful? , 2010, European heart journal.

[21]  Jan Sijbers,et al.  Automatic Construction of Correspondences for Tubular Surfaces , 2010, IEEE Transactions on Pattern Analysis and Machine Intelligence.

[22]  Gaël Varoquaux,et al.  Scikit-learn: Machine Learning in Python , 2011, J. Mach. Learn. Res..

[23]  Alejandro F Frangi,et al.  Computational cardiac atlases: from patient to population and back , 2009, Experimental physiology.

[24]  Vladimir Kolmogorov,et al.  An experimental comparison of min-cut/max- flow algorithms for energy minimization in vision , 2001, IEEE Transactions on Pattern Analysis and Machine Intelligence.

[25]  Stefan Zachow,et al.  Reconstruction of mandibular dysplasia using a statistical 3D shape model , 2005 .

[26]  Jos Vander Sloten,et al.  A validated methodology for patient specific computational modeling of self-expandable transcatheter aortic valve implantation. , 2016, Journal of biomechanics.

[27]  Rasmus Reinhold Paulsen,et al.  Building and Testing a Statistical Shape Model of the Human Ear Canal , 2002, MICCAI.

[28]  M. Leon,et al.  Cross-sectional computed tomographic assessment improves accuracy of aortic annular sizing for transcatheter aortic valve replacement and reduces the incidence of paravalvular aortic regurgitation. , 2012, Journal of the American College of Cardiology.

[29]  Sanjay Kaul,et al.  2012 ACCF/AATS/SCAI/STS expert consensus document on transcatheter aortic valve replacement. , 2012, Journal of the American College of Cardiology.

[30]  Paul M. Thompson,et al.  Applying tensor-based morphometry to parametric surfaces can improve MRI-based disease diagnosis , 2013, NeuroImage.

[31]  Timothy F. Cootes,et al.  A minimum description length approach to statistical shape modeling , 2002, IEEE Transactions on Medical Imaging.

[32]  Alejandro F. Frangi,et al.  Statistical Shape Modeling Using Partial Least Squares: Application to the Assessment of Myocardial Infarction , 2015, STACOM@MICCAI.

[33]  Yaozong Gao,et al.  Estimating Anatomically-Correct Reference Model for Craniomaxillofacial Deformity via Sparse Representation , 2014, MICCAI.

[34]  M. Morice,et al.  Impact of CT-guided valve sizing on post-procedural aortic regurgitation in transcatheter aortic valve implantation. , 2012, EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology.

[35]  Milan Sonka,et al.  Congenital aortic disease: 4D magnetic resonance segmentation and quantitative analysis , 2009, Medical Image Anal..

[36]  Martin Styner,et al.  Evaluation of 3D Correspondence Methods for Model Building , 2003, IPMI.

[37]  Timothy F. Cootes,et al.  Use of active shape models for locating structures in medical images , 1994, Image Vis. Comput..