Fundamental imaging characteristics of a slot-scan digital chest radiographic system.

Our purpose in this study was to evaluate the fundamental image quality characteristics of a new slot-scan digital chest radiography system (ThoraScan, Delft Imaging Systems/Nucletron, Veenendaal, The Netherlands). The linearity of the system was measured over a wide exposure range at 90, 117, and 140 kVp with added Al filtration. System uniformity and reproducibility were established with an analysis of images from repeated exposures. The modulation transfer function (MTF) was evaluated using an established edge method. The noise power spectrum (NPS) and the detective quantum efficiency (DQE) of the system were evaluated at the three kilo-voltages over a range of exposures. Scatter fraction (SF) measurements were made using a posterior beam stop method and a geometrical chest phantom. The system demonstrated excellent linearity, but some structured nonuniformities. The 0.1 MTF values occurred between 3.3-3.5 mm(-1). The DQE(0.15) and DQE(2.5) were 0.21 and 0.07 at 90 kVp, 0.18 and 0.05 at 117 kVp, and 0.16 and 0.03 at 140 kVp, respectively. The system exhibited remarkably lower SFs compared to conventional full-field systems with anti-scatter grid, measuring 0.13 in the lungs and 0.43 in the mediastinum. The findings indicated that the slot-scan design provides marked scatter reduction leading to high effective DQE (DQEeff) of the system and reduced patient dose required to achieve high image quality.

[1]  Ehsan Samei Image quality in two phosphor-based flat panel digital radiographic detectors. , 2003, Medical physics.

[2]  William Des Jardin,et al.  Large-format high-performance CCD sensor for medical x-ray applications , 2000, Medical Imaging.

[3]  C E Ravin,et al.  Small object contrast in AMBER and conventional chest radiography. , 1991, Radiology.

[4]  C E Ravin,et al.  Measurement of scatter fractions in erect posteroanterior and lateral chest radiography. , 1993, Radiology.

[5]  D. P. Trauernicht,et al.  System considerations in CCD-based x-ray imaging for digital chest radiography and digital mammography. , 1997, Medical physics.

[6]  Ehsan Samei,et al.  An experimental comparison of detector performance for direct and indirect digital radiography systems. , 2003, Medical physics.

[7]  H. Blume,et al.  DQE(f) of four generations of computed radiography acquisition devices. , 1995, Medical physics.

[8]  R. F. Wagner,et al.  Effect of reduced scatter on radiographic information content and patient exposure: a quantitative demonstration. , 1980, Medical physics.

[9]  E. Samei,et al.  A method for measuring the presampled MTF of digital radiographic systems using an edge test device. , 1998, Medical physics.

[10]  U Neitzel,et al.  Image quality of a digital chest radiography system based on a selenium detector. , 1994, Medical physics.

[11]  Mathias Prokop,et al.  Principles of image processing in digital chest radiography. , 2003, Journal of thoracic imaging.

[12]  A Fenster,et al.  A time-delay integration charge-coupled device camera for slot-scanned digital radiography. , 1990, Medical physics.

[13]  J A Rowlands,et al.  X-ray detectors for digital radiography. , 1997, Physics in medicine and biology.

[14]  E. Samei,et al.  Experimental comparison of noise and resolution for 2k and 4k storage phosphor radiography systems. , 1999, Medical physics.

[15]  J A Rowlands,et al.  Flat-panel digital radiology with amorphous selenium and active-matrix readout. , 1997, Radiographics : a review publication of the Radiological Society of North America, Inc.

[16]  Ehsan Samei,et al.  An experimental comparison of detector performance for computed radiography systems. , 2002, Medical physics.

[17]  C E Ravin,et al.  Imaging characteristics of an amorphous silicon flat-panel detector for digital chest radiography. , 2001, Radiology.

[18]  C E Ravin,et al.  Measurement of scatter fractions in clinical bedside radiography. , 1992, Radiology.

[19]  Martin J Yaffe,et al.  A slot-scanned photodiode-array/CCD hybrid detector for digital mammography. , 2002, Medical physics.

[20]  J A Seibert,et al.  Performance evaluation of computed radiography systems. , 2001, Medical physics.

[21]  J A Sorenson,et al.  Performance characteristics of improved antiscatter grids. , 1980, Medical physics.

[22]  C E Ravin,et al.  Scatter fractions in AMBER imaging. , 1990, Radiology.