Characterization of a third-generation Faraday-strip array detector coupled to a Mattauch-Herzog geometry mass spectrograph with a dc-glow discharge ionization source

A third-generation Faraday-strip array detector has been coupled to a Mattauch-Herzog mass spectrometer and dc glow-discharge ionization source. This combination offers simultaneous determination of multiple elements directly from solid samples and provides superior resolving power and improved limits of detection over previous generations of array detectors. With the third-generation detector array, resolving power is limited only by the mass spectrometer and not by the array. Because of this enhanced resolution, limits of detection, especially for higher mass-to-charge ratios, were improved. Isotope-ratio precision was found to be 0.07% RSD on average and quantitative response was linear over 5 orders of magnitude.

[1]  G. Hieftje,et al.  Evaluation of a 512-channel Faraday-strip array detector coupled to an inductively coupled plasma Mattauch-Herzog mass spectrograph. , 2009, Analytical chemistry.

[2]  James H Barnes,et al.  Characterization of a second-generation focal-plane camera coupled to an inductively coupled plasma Mattauch-Herzog geometry mass spectrograph. , 2006, Analytical chemistry.

[3]  M. B. Denton,et al.  Simultaneous multichannel mass-specific detection for high-performance liquid chromatography using an array detector sector-field mass spectrometer , 2004, Analytical and bioanalytical chemistry.

[4]  G. Hieftje,et al.  Coupling of a gas chromatograph to a simultaneous-detection inductively coupled plasma mass spectrograph for speciation of organohalide and organometallic compounds , 2004 .

[5]  M. B. Denton,et al.  Characterization of a focal plane camera fitted to a Mattauch-Herzog geometry mass spectrograph. 2. Use with an inductively coupled plasma. , 2004, Analytical chemistry.

[6]  M. B. Denton,et al.  Characterization of a focal plane camera fitted to a Mattauch-Herzog geometry mass spectrograph. 1. Use with a glow-discharge source. , 2002, Analytical chemistry.

[7]  G. Hieftje,et al.  Advancing the capabilities of a glow-discharge sector-field mass spectrometer , 2002 .

[8]  O. Grøn,et al.  Analytical capabilities of an inductively coupled plasma Mattauch–Herzog mass spectrometer , 2001 .

[9]  G. Hieftje,et al.  Plasma-source sector mass spectrometry with array detection , 1999 .

[10]  R. Hites,et al.  Design and performance of a plasma-source mass spectrograph , 1997 .

[11]  J. Mattauch A Double-Focusing Mass Spectrograph and the Masses of N 15 and O 18 , 1936 .

[12]  J. Mattauch,et al.  Über einen neuen Massenspektrographen , 1934 .