Evaluation of a polyaxial angle-stable volar plate in a distal radius C-fracture model--a biomechanical study.
暂无分享,去创建一个
Boyko Gueorguiev | Markus Windolf | Thomas Mückley | Gunther O Hofmann | G. Hofmann | F. Gras | K. Klos | T. Mückley | M. Windolf | B. Gueorguiev | Sascha Rausch | Kajetan Klos | Helen Stephan | Konrad Hoffmeier | Florian Gras | K. Hoffmeier | S. Rausch | Helen Stephan
[1] Randal P. Morris,et al. Comparison of different distal radius dorsal and volar fracture fixation plates: a biomechanical study. , 2003, The Journal of hand surgery.
[2] H. Drobetz,et al. Osteosynthesis of distal radial fractures with a volar locking screw plate system , 2002, International Orthopaedics.
[3] K. Koval,et al. A Biomechanical Comparison of a Dorsal 3.5-mm T-Plate and a Volar Fixed-Angle Plate in a Model of Dorsally Unstable Distal Radius Fractures , 2005, Journal of orthopaedic trauma.
[4] P Regazzoni,et al. Comparison of three different plating techniques for the dorsum of the distal radius: a biomechanical study. , 2000, The Journal of hand surgery.
[5] R. L. Linscheid,et al. Force distribution across wrist joint: application of pressure-sensitive conductive rubber. , 1992, The Journal of hand surgery.
[6] Kapil Kumar,et al. Displaced distal radial fractures treated using volar locking plates: maintenance of normal anatomy. , 2009, The Journal of trauma.
[7] Akira Ikeda,et al. Biomechanics of the Wrist Joint , 2011 .
[8] A. Bryant,et al. Volar fixed-angle plating of distal radius extension fractures: influence of plate position on secondary loss of reduction--a biomechanic study in a cadaveric model. , 2006, The Journal of hand surgery.
[9] C. Voigt,et al. Welche Vorteile bietet die volare Plattenosteosynthese gegenüber der Kirschner-Drahtstabilisierung bei distalen Radiusextensionsfrakturen des alten Menschen? , 2006, Der Unfallchirurg.
[10] D. Zlotolow. Comparison of External and Percutaneous Pin Fixation with Plate Fixation for Intra-Articular Distal Radial Fractures: A Randomized Study , 2009 .
[11] M. Al-Rashid,et al. Delayed ruptures of the extensor tendon secondary to the use of volar locking compression plates for distal radial fractures. , 2006, The Journal of bone and joint surgery. British volume.
[12] R. L. Linscheid,et al. Forces in the normal and abnormal hand , 1985, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.
[13] J. Orbay,et al. Volar fixation for dorsally displaced fractures of the distal radius: a preliminary report. , 2002, The Journal of hand surgery.
[14] G. Gradl,et al. A novel non-bridging external fixator construct versus volar angular stable plating for the fixation of intra-articular fractures of the distal radius--a biomechanical study. , 2010, Injury.
[15] P. Stern,et al. Volar neutralization plate fixation of dorsally displaced distal radius fractures. , 2002, Orthopedics.
[16] H. Lill,et al. [What advantages does volar plate fixation have over K-wire fixation for distal radius extension fractures in the elderly?]. , 2006, Der Unfallchirurg.
[17] A. Amis,et al. The Palmar Locking Compression Plate is Biomechanically Comparable to the Dorsal PI Plate for Dorsally Comminuted, Intraarticular Wrist Fractures , 2007 .
[18] P. Regazzoni,et al. Fractures of the distal end of the radius treated by internal fixation and early function. A preliminary report of 20 cases. , 1996, The Journal of bone and joint surgery. British volume.
[19] N. Gjerdet,et al. Different osteosyntheses for Colles' fracture , 2009, Acta orthopaedica.
[20] Cemal Kural,et al. [Volar plate fixation of distal radius fractures]. , 2012, Ulusal travma ve acil cerrahi dergisi = Turkish journal of trauma & emergency surgery : TJTES.
[21] H. Krimmer,et al. [Multidirectional palmar fixed-angle plate fixation for unstable distal radius fracture]. , 2007, Handchirurgie, Mikrochirurgie, plastische Chirurgie : Organ der Deutschsprachigen Arbeitsgemeinschaft fur Handchirurgie : Organ der Deutschsprachigen Arbeitsgemeinschaft fur Mikrochirurgie der Peripheren Nerven und Gefasse : Organ der V....
[22] G. Hofmann,et al. The strength of polyaxial locking interfaces of distal radius plates. , 2009, Clinical biomechanics.
[23] G. Hofmann,et al. A biomechanical comparison of a biodegradable volar locked plate with two titanium volar locked plates in a distal radius fracture model. , 2009, The Journal of trauma.
[24] J L Lewis,et al. Distal radial metaphyseal forces in an extrinsic grip model: implications for postfracture rehabilitation. , 2000, Journal of Hand Surgery-American Volume.
[25] T. Trumble,et al. Percutaneous pins versus volar plates for unstable distal radius fractures: a biomechanic study using a cadaver model. , 2007, The Journal of hand surgery.
[26] Erik N. Kubiak,et al. A biomechanical comparison of two volar locked plates in a dorsally unstable distal radius fracture model. , 2006, The Journal of trauma.
[27] J Goldhahn,et al. The potential of bioresorbable plates and screws in distal radius fracture fixation. , 2002, Injury.
[28] R. R. Slater. Internal Fixation of Dorsally Displaced Fractures of the Distal Part of the Radius: A Biomechanical Analysis of Volar Plate Fracture Stability , 2008 .
[29] E. B. Toby,et al. Locking versus nonlocking T-plates for dorsal and volar fixation of dorsally comminuted distal radius fractures: a biomechanical study. , 2005, The Journal of hand surgery.
[30] S. Trigg. Volar Versus Dorsal Fixed-Angle Fixation of Dorsally Unstable Extra-Articular Distal Radius Fractures: A Biomechanic Study , 2008 .
[31] N. Downing,et al. A revolution in the management of fractures of the distal radius? , 2008, The Journal of bone and joint surgery. British volume.