Rebinning-based algorithms for helical cone-beam CT.

Several image reconstruction algorithms based on rebinning have been proposed recently for helical cone-beam CT. These algorithms separate the 3D reconstruction into a set of independent 2D reconstructions for a set of surfaces: planar or non-planar surfaces are defined and then reconstructed using 2D filtered backprojection from a 2D fan-beam or parallel-beam set of data estimated from the cone-beam (CB) measurements. The first part of this paper presents a unified derivation of rebinning algorithms for planar and non-planar surfaces. An integral equation is derived for the surface allowing the best rebinning and an iterative algorithm converging to the solution of that equation is given. The second part presents an efficient method to correct the residual reconstruction artefacts observed with rebinning algorithms when the cone-angle is too large for the required accuracy. This correction algorithm involves a CB backprojection and the reconstruction time is slightly longer than for the zero-boundary (ZB) method.

[1]  Marc Kachelriess,et al.  Single-slice reconstruction in spiral cone-beam computed tomography , 2000, IEEE Trans. Medical Imaging.

[2]  Günter Lauritsch,et al.  Exact Radon rebinning algorithm for the long object problem in helical cone-beam CT , 2000, IEEE Transactions on Medical Imaging.

[3]  Hiroyuki Kudo,et al.  Quasi-exact filtered backprojection algorithm for long-object problem in helical cone-beam tomography , 2000, IEEE Transactions on Medical Imaging.

[4]  Akram Aldroubi,et al.  B-SPLINE SIGNAL PROCESSING: PART II-EFFICIENT DESIGN AND APPLICATIONS , 1993 .

[5]  Michael Grass,et al.  The n-PI-method for helical cone-beam CT , 2000, IEEE Transactions on Medical Imaging.

[6]  Richard M. Leahy,et al.  Cone beam tomography with circular, elliptical and spiral orbits , 1992 .

[7]  Jens Krause,et al.  Spiral Interpolation Algorithms for Multi-Slice Spiral CT Part I: Theory , 2000, IEEE Trans. Medical Imaging.

[8]  Akram Aldroubi,et al.  B-spline signal processing. II. Efficiency design and applications , 1993, IEEE Trans. Signal Process..

[9]  G. Wang,et al.  A general cone-beam reconstruction algorithm , 1993, IEEE Trans. Medical Imaging.

[10]  Kwok C. Tam Exact local regions-of-interest reconstruction in spiral cone-beam filtered-backprojection CT: theory , 2000, Medical Imaging: Image Processing.

[11]  R Y Levine,et al.  Optimum beam configurations in tomographic intensity modulated radiation therapy. , 2000, Physics in medicine and biology.

[12]  Hiroyuki Kudo,et al.  Performance of quasi-exact cone-beam filtered backprojection algorithm for axially truncated helical data , 1998 .

[13]  Thomas J. Flohr,et al.  New efficient Fourier-reconstruction method for approximate image reconstruction in spiral cone-beam CT at small cone angles , 1997, Medical Imaging.

[14]  M. Defrise,et al.  Cone-beam filtered-backprojection algorithm for truncated helical data. , 1998, Physics in medicine and biology.

[15]  Per-Erik Danielsson,et al.  The PI-method: non-redundant data capture and efficient reconstruction for helical cone-beam CT , 1998, 1998 IEEE Nuclear Science Symposium Conference Record. 1998 IEEE Nuclear Science Symposium and Medical Imaging Conference (Cat. No.98CH36255).

[16]  L. Feldkamp,et al.  Practical cone-beam algorithm , 1984 .

[17]  M. Defrise,et al.  Single-slice rebinning method for helical cone-beam CT. , 1999, Physics in medicine and biology.

[18]  M. Defrise,et al.  A solution to the long-object problem in helical cone-beam tomography. , 2000, Physics in medicine and biology.

[19]  Michael Unser,et al.  B-spline signal processing. I. Theory , 1993, IEEE Trans. Signal Process..

[20]  Per-Erik Danielsson,et al.  An improved PI-method for reconstruction from helical cone-beam projections , 1999, 1999 IEEE Nuclear Science Symposium. Conference Record. 1999 Nuclear Science Symposium and Medical Imaging Conference (Cat. No.99CH37019).

[21]  S. Samarasekera,et al.  Exact cone beam CT with a spiral scan. , 1998, Physics in medicine and biology.

[22]  P. Grangeat Mathematical framework of cone beam 3D reconstruction via the first derivative of the radon transform , 1991 .

[23]  M D Silver,et al.  High-helical-pitch, cone-beam computed tomography. , 1998, Physics in medicine and biology.

[24]  Avinash C. Kak,et al.  Principles of computerized tomographic imaging , 2001, Classics in applied mathematics.

[25]  D. Parker Optimal short scan convolution reconstruction for fan beam CT , 1982 .

[26]  Marc Kachelriess,et al.  Advanced single-slice rebinning in cone-beam spiral CT: theoretical considerations and medical applications , 2000, Medical Imaging: Image Processing.

[27]  Marc Kachelrieß,et al.  Advanced single-slice rebinning in cone-beam spiral CT: theoretical considerations and medical applications , 2000, Image Processing.

[28]  M. Defrise,et al.  Approximate short-scan filtered-backprojection for helical CB reconstruction , 1998, 1998 IEEE Nuclear Science Symposium Conference Record. 1998 IEEE Nuclear Science Symposium and Medical Imaging Conference (Cat. No.98CH36255).

[29]  Y. Liu,et al.  Half-scan cone-beam x-ray microtomography formula. , 2008, Scanning.

[30]  Henrik Turbell,et al.  Cone-Beam Reconstruction Using Filtered Backprojection , 2001 .