Mysteries of LiF TLD response following high ionization density irradiation: Glow curve shapes, dose response, the unified interaction model and modified track structure theory
暂无分享,去创建一个
A. Rosenfeld | H. Datz | Y. Horowitz | L. Oster | J. Livingstone | E. Fuks
[1] M. Margaliot,et al. Energy dependence of the supralinearity (f(D)max) of peaks 7 and 8 in the high temperature thermoluminescence of LiF:Mg,Ti (TLD-100): Interpretation using the unified interaction model , 2011 .
[2] A. Rosenfeld,et al. Mysteries of LiF TLD response following high ionisation density irradiation: nanodosimetry and track structure theory, dose response and glow curve shapes. , 2011, Radiation protection dosimetry.
[3] A. Rosenfeld,et al. Thermoluminescence solid-state nanodosimetry--the peak 5A/5 dosemeter. , 2011, Radiation protection dosimetry.
[4] Y. Horowitz,et al. OSL and TL in TLD-100 following alpha and beta irradiation: Application to mixed-field radiation dosimetry , 2010 .
[5] A. Rosenfeld,et al. Experimental investigation of the 100 keV X-ray dose response of the high-temperature thermoluminescence in LiF:Mg,Ti (TLD-100): theoretical interpretation using the unified interaction model. , 2010, Radiation protection dosimetry.
[6] Y. Horowitz,et al. Ionization density effects following F-centre optical excitation in LiF : Mg, Ti (TLD-100): analysis via track structure theory , 2009 .
[7] T. Berger,et al. TL-efficiency—Overview and experimental results over the years , 2008 .
[8] M. Brandan,et al. Onset of supralinear response in TLD-100 exposed to 60Co gamma-rays , 2006 .
[9] P. Olko,et al. The effects of ionisation density on the thermoluminescence response (efficiency) of LiF:Mg,Ti and LiF:Mg,Cu,P. , 2004, Radiation protection dosimetry.
[10] Y. Horowitz,et al. Localized transitions in the thermoluminescence of LiF : Mg,Ti: potential for nanoscale dosimetry , 2003 .
[11] A. Buenfil,et al. On the correct measurement of relative heavy charged particles to gamma thermoluminescent efficiencies. , 2002, Radiation protection dosimetry.
[12] M. Brandan,et al. Influence of fdelta(D) on modified track structure theory efficiency calculations. , 2002, Radiation protection dosimetry.
[13] Y. S. Horowitz,et al. Theory of thermoluminescence gamma dose response: The unified interaction model , 2001 .
[14] Y. Weizman,et al. Investigation of the composite structure of peak 5 in the thermoluminescent glow curve of LiF:Mg,Ti (TLD-100) using optical bleaching , 1999 .
[15] M. Brandan,et al. Study of the energy deposition in LiF by heavy charged particle irradiation and its relation to the thermoluminescent efficiency of the material , 1999 .
[16] A. Buenfil,et al. Thermoluminescent response and relative efficiency of TLD-100 exposed to low-energy x-rays. , 1998, Physics in medicine and biology.
[17] G. Kraft,et al. Efficiency of thermoluminescent detectors to heavy charged particles , 1998 .
[18] J. E. Turner,et al. Microdosimetry and Its Applications. H. H. Rossi , M. Zaider , 1996 .
[19] Y. Horowitz,et al. Beta ray spectroscopy based on a plastic scintillation detector/silicon surface barrier detector coincidence telescope , 1994 .
[20] N. Nariyama,et al. Responses of LiF TLDs to 10-40 keV Monoenergetic Photons from Synchrotron Radiation , 1993 .
[21] D. Pearson,et al. Thermoluminescent Response of Lithium Fluoride (TLD-100) to Monoenergetic Photon Beams of 600, 730, 900 and 1,500 eV , 1993 .
[22] M. Folkard,et al. Measurement and analysis of supralinearity in LiF TLD-100 irradiated by 1.5 keV x-rays. , 1989, Physics in medicine and biology.
[23] H. Ing,et al. A short atlas of beta-ray spectra , 1983 .
[24] J. Kalef-Ezra,et al. Heavy charged particle thermoluminescence dosimetry: Track structure theory and experiments , 1982 .
[25] M. Waligórski,et al. Supralinearity of peak 5 and peak 6 in TLD-700 , 1980 .
[26] P. R. Moran,et al. Thermoluminescent response of LiF (TLD-100) to 5-30 keV electrons and the effect of annealing in various atmospheres. , 1977, Physics in medicine and biology.
[27] Y. Horowitz. Microdosimetric response of physical and biological systems to low- and high-LET radiations : theory and applications to dosimetry , 2006 .
[28] Y. Horowitz. A Unified and Comprehensive Theory of the TL Dose Response of Thermoluminescent Systems Applied to LiF:Mg,Ti , 2006 .
[29] F A Cucinotta,et al. Radial distribution of electron spectra from high-energy ions , 1998, Radiation and environmental biophysics.