BPF-based Grid Voltage Feedforward Control of Grid-connected Converters for Improving Robust Stability

Grid voltage feedforward is extensively used for controlling grid-connected converters. However, the conventional voltage feedforward control reduces the stability margins of the converter connected to a high-impedance grid. The effect mechanism of voltage feedforward on the grid-connected converter control under high-inductive conditions of the grid impedance is clearly explained in this study using the equivalent transformations of control block diagrams. Results show that the delay produced by the digital control is the root cause of this effect. An improved voltage feedforward strategy, in which a bandpass filter (BPF) is introduced into the feedforward path, is proposed to strengthen the converter’s robust stability against grid impedance variations. The selection method of the BPF’s bandwidth is also provided considering the tradeoff between the response speed to the grid voltage sag and the system’s robust stability. The converter can work stably over a wide range of the grid impedance through the proposed approach. Simulation and experimental results fully verify the effectiveness of the BPF-based voltage feedforward strategy.

[1]  Guozhu Chen,et al.  Design and Research on High-Reliability HPEBB Used in Cascaded DSTATCOM , 2015 .

[2]  J L Agorreta,et al.  Modeling and Control of $N$ -Paralleled Grid-Connected Inverters With LCL Filter Coupled Due to Grid Impedance in PV Plants , 2011, IEEE Transactions on Power Electronics.

[3]  Li Tong,et al.  LCL type grid-connected converter no startup inrush current control method based on capacitor branch voltage feedforward , 2015, IECON 2015 - 41st Annual Conference of the IEEE Industrial Electronics Society.

[4]  A. Gole,et al.  Impact of Short-Circuit Ratio and Phase-Locked-Loop Parameters on the Small-Signal Behavior of a VSC-HVDC Converter , 2014, IEEE Transactions on Power Delivery.

[5]  Chen Chen,et al.  A Modified Capacitor Current Feedback Active Damping Approach for Grid Connected Converters with an LCL Filter , 2015 .

[6]  Bo Wen,et al.  Analysis of D-Q Small-Signal Impedance of Grid-Tied Inverters , 2016, IEEE Transactions on Power Electronics.

[7]  Tsai-Fu Wu,et al.  Predictive Current Controlled 5-kW Single-Phase Bidirectional Inverter With Wide Inductance Variation for DC-Microgrid Applications , 2010, IEEE Transactions on Power Electronics.

[8]  M. Liserre,et al.  Grid Impedance Estimation via Excitation of $LCL$ -Filter Resonance , 2007, IEEE Transactions on Industry Applications.

[9]  Xiaohu Zhou,et al.  High-Frequency Resonance Mitigation for Plug-In Hybrid Electric Vehicles’ Integration With a Wide Range of Grid Conditions , 2012, IEEE Transactions on Power Electronics.

[10]  Xinbo Ruan,et al.  Optimized Controller Design for $LCL$-Type Grid-Connected Inverter to Achieve High Robustness Against Grid-Impedance Variation , 2015, IEEE Transactions on Industrial Electronics.

[11]  Seon-Yeong Jeong,et al.  Active Damping of LLCL Filters Using PR Control for Grid-Connected Three-Level T-Type Converters , 2015 .

[12]  Steven E. Widergren,et al.  An Orderly Transition to a Transformed Electricity System , 2010, IEEE Transactions on Smart Grid.

[13]  Shaojun Xie,et al.  Evaluations of current control in weak grid case for grid-connected LCL-filtered inverter , 2013 .

[14]  Wei Hu,et al.  A Resonant Characteristics Analysis and Suppression Strategy for Multiple Parallel Grid-connected Inverters with LCL Filter , 2016 .

[15]  Manigandan Thathan,et al.  Modelling and analysis of modular multilevel converter for solar photovoltaic applications to improve power quality , 2015 .

[16]  M. Liserre,et al.  Stability of photovoltaic and wind turbine grid-connected inverters for a large set of grid impedance values , 2006, IEEE Transactions on Power Electronics.

[17]  F. Blaabjerg,et al.  An LLCL Power Filter for Single-Phase Grid-Tied Inverter , 2012, IEEE Transactions on Power Electronics.

[18]  Josep M. Guerrero,et al.  Stationary Frame Current Control Evaluations for Three-Phase Grid-Connected Inverters with PVR-based Active Damped LCL Filters , 2016 .

[19]  Hans-Peter Nee,et al.  Interconnection of Two Very Weak AC Systems by VSC-HVDC Links Using Power-Synchronization Control , 2011, IEEE Transactions on Power Systems.

[20]  Jun Yang,et al.  An LTCL Filter for Three-Phase Grid-Connected Converters , 2014, IEEE Transactions on Power Electronics.

[21]  Gayadhar Panda,et al.  Harmonic Elimination and Reactive Power Compensation with a Novel Control Algorithm based Active Power Filter , 2015 .

[22]  Shuai Jiang,et al.  Grid-Connected Boost-Half-Bridge Photovoltaic Microinverter System Using Repetitive Current Control and Maximum Power Point Tracking , 2012, IEEE Transactions on Power Electronics.

[23]  Shaojun Xie,et al.  Improved control strategy with grid-voltage feedforward for LCL-filter-based inverter connected to weak grid , 2014 .