Effectiveness of Low Levels of Nonventilated Lung Continuous Positive Airway Pressure in Improving Arterial Oxygenation During One‐Lung Ventilation

Continuous positive airway pressure (CPAP) of 5 and 10 cm H2O applied to the nonventilated lung is effective in improving arterial oxygenation during one-lung ventilation (1-LV). The effectiveness of lower levels of CPAP on improving oxygenation, however, has not been reported, possibly because of limitations of previous methods of CPAP delivery. Recently, a disposable, self-assembled CPAP system capable of delivering CPAP over a wide range of pressures has been introduced (Mallinckrodt Medical, Inc., St. Louis, MO). The purpose of this study was to evaluate the effectiveness of 2 and 5 cm H2O of CPAP delivered with this device in improving Pao2, in thoracic surgical patients during 1 -LV. Twenty patients scheduled for thoracotomy were anesthetized and a left-sided endobronchial tube was placed with fiberoptic bronchoscopic guidance. Patients were ventilated with a tidal volume of 12 mL/kg, an F102, of 1.0, and the respiratory rate was adjusted to maintain Paco, at 40 ± 4 mm Hg. Patients were randomized to receive nonventilated lung CPAP at either the 2 (Group I) or 5 (Group 11) cm H2O pressure setting of the device. Application of CPAP followed 20 min of stable 1-LV in the lateral decubitus position. Compared with two-lung ventilation, Pao2 (mean ± SD) was significantly less with I-LV (Group I, 126 ± 75 mm Hg, and Group 11,173 2 79 mm Hg). Application of the assigned CPAP resulted in an increase in Pao2 compared to 1-LV (Group I, 270 ± 112 mm Hg, and Group11, 386 ± 66 mm Hg, P < 0.05). Nonventilated lung airway pressure with the CPAP system at the 2 and 5 settings was 2.6 ± 0.4 and 5.5 ± 0.5 cm H2O, respectively. These results demonstrate that during 1-LV, improvement in arterial oxygenation with nonventilated lung CPAP can be achieved with both the 2 and 5 cm H2O CPAP settings of the Mallinckrodt CPAP system.

[1]  G. Topulos,et al.  Flow sensitivity of the Mallinckrodt Continuous Positive Airway Pressure device. , 1992, Journal of cardiothoracic and vascular anesthesia.

[2]  D. Thys,et al.  Oxygenation and hemodynamic changes during one-lung ventilation: effects of CPAP10, PEEP10, and CPAP10/PEEP10. , 1988, Journal of cardiothoracic anesthesia.

[3]  P. Slinger,et al.  Improving arterial oxygenation during one-lung ventilation. , 1988, Anesthesiology.

[4]  A. Baraka,et al.  CPAP oxygenation during one-lung ventilation using an underwater seal assembly. , 1986, Anesthesiology.

[5]  J. Benumof One‐Lung Ventilation and Hypoxic Pulmonary Vasoconstriction: Implications for Anesthetic Management , 1985, Anesthesia and analgesia.

[6]  R. F. Davis,et al.  A simple device for oxygen insufflation with continuous positive airway pressure during one-lung ventilation. , 1984, Anesthesiology.

[7]  A. Hannenberg,et al.  A device for applying CPAP to the nonventilated upper lung during one-lung ventilation. II. , 1984, Anesthesiology.

[8]  H. Turndorf,et al.  Optimization of Arterial Oxygenation during One‐Lung Anesthesia , 1980, Anesthesia and analgesia.

[9]  P. Boysen Pulmonary resection and postoperative pulmonary function. , 1980, Chest.

[10]  T. Torda,et al.  PULMONARY VENOUS ADMIXTURE DURING ONE-LUNG ANAESTHESIA. THE EFFECT OF INHALED OXYGEN-TENSION AND RESPIRATION RATE , 1975 .

[11]  D. F. Thomson,et al.  CHANGES IN ARTERIAL OXYGEN TENSION DURING ONE-LUNG ANAESTHESIA , 1973 .