Continuous positive airway pressure (CPAP) of 5 and 10 cm H2O applied to the nonventilated lung is effective in improving arterial oxygenation during one-lung ventilation (1-LV). The effectiveness of lower levels of CPAP on improving oxygenation, however, has not been reported, possibly because of limitations of previous methods of CPAP delivery. Recently, a disposable, self-assembled CPAP system capable of delivering CPAP over a wide range of pressures has been introduced (Mallinckrodt Medical, Inc., St. Louis, MO). The purpose of this study was to evaluate the effectiveness of 2 and 5 cm H2O of CPAP delivered with this device in improving Pao2, in thoracic surgical patients during 1 -LV. Twenty patients scheduled for thoracotomy were anesthetized and a left-sided endobronchial tube was placed with fiberoptic bronchoscopic guidance. Patients were ventilated with a tidal volume of 12 mL/kg, an F102, of 1.0, and the respiratory rate was adjusted to maintain Paco, at 40 ± 4 mm Hg. Patients were randomized to receive nonventilated lung CPAP at either the 2 (Group I) or 5 (Group 11) cm H2O pressure setting of the device. Application of CPAP followed 20 min of stable 1-LV in the lateral decubitus position. Compared with two-lung ventilation, Pao2 (mean ± SD) was significantly less with I-LV (Group I, 126 ± 75 mm Hg, and Group 11,173 2 79 mm Hg). Application of the assigned CPAP resulted in an increase in Pao2 compared to 1-LV (Group I, 270 ± 112 mm Hg, and Group11, 386 ± 66 mm Hg, P < 0.05). Nonventilated lung airway pressure with the CPAP system at the 2 and 5 settings was 2.6 ± 0.4 and 5.5 ± 0.5 cm H2O, respectively. These results demonstrate that during 1-LV, improvement in arterial oxygenation with nonventilated lung CPAP can be achieved with both the 2 and 5 cm H2O CPAP settings of the Mallinckrodt CPAP system.
[1]
G. Topulos,et al.
Flow sensitivity of the Mallinckrodt Continuous Positive Airway Pressure device.
,
1992,
Journal of cardiothoracic and vascular anesthesia.
[2]
D. Thys,et al.
Oxygenation and hemodynamic changes during one-lung ventilation: effects of CPAP10, PEEP10, and CPAP10/PEEP10.
,
1988,
Journal of cardiothoracic anesthesia.
[3]
P. Slinger,et al.
Improving arterial oxygenation during one-lung ventilation.
,
1988,
Anesthesiology.
[4]
A. Baraka,et al.
CPAP oxygenation during one-lung ventilation using an underwater seal assembly.
,
1986,
Anesthesiology.
[5]
J. Benumof.
One‐Lung Ventilation and Hypoxic Pulmonary Vasoconstriction: Implications for Anesthetic Management
,
1985,
Anesthesia and analgesia.
[6]
R. F. Davis,et al.
A simple device for oxygen insufflation with continuous positive airway pressure during one-lung ventilation.
,
1984,
Anesthesiology.
[7]
A. Hannenberg,et al.
A device for applying CPAP to the nonventilated upper lung during one-lung ventilation. II.
,
1984,
Anesthesiology.
[8]
H. Turndorf,et al.
Optimization of Arterial Oxygenation during One‐Lung Anesthesia
,
1980,
Anesthesia and analgesia.
[9]
P. Boysen.
Pulmonary resection and postoperative pulmonary function.
,
1980,
Chest.
[10]
T. Torda,et al.
PULMONARY VENOUS ADMIXTURE DURING ONE-LUNG ANAESTHESIA. THE EFFECT OF INHALED OXYGEN-TENSION AND RESPIRATION RATE
,
1975
.
[11]
D. F. Thomson,et al.
CHANGES IN ARTERIAL OXYGEN TENSION DURING ONE-LUNG ANAESTHESIA
,
1973
.