Performance Comparison of PD Data Acquisition Techniques for Condition Monitoring of Medium Voltage Cables

Already installed cables are aging and the cable network is growing rapidly. Improved condition monitoring methods are required for greater visibility of insulation defects in the cable networks. One of the critical challenges for continuous monitoring is the large amount of partial discharge (PD) data that poses constraints on the diagnostic capabilities. This paper presents the performance comparison of two data acquisition techniques based on phase resolved partial discharge (PRPD) and pulse acquisition (PA). The major contribution of this work is to provide an in-depth understanding of these techniques considering the perspective of randomness of the PD mechanism and improvements in the reliability of diagnostics. Experimental study is performed on the medium voltage (MV) cables in the laboratory environment. It has been observed that PRPD based acquisition not only requires a significantly larger amount of data but is also susceptible to losing the important information especially when multiple PD sources are being investigated. On the other hand, the PA technique presents improved performance for PD diagnosis. Furthermore, the use of the PA technique enables the efficient practical implementation of the continuous PD monitoring by reducing the amount of data that is acquired by extracting useful signals and discarding the silent data intervals.

[1]  Mohamad Ghaffarian Niasar,et al.  Partial Discharge Signatures of Defects in Insulation Systems Consisting of Oil and Oil-impregnated Paper , 2012 .

[2]  J.D. van Wyk,et al.  An overview of integratable current sensor technologies , 2003, 38th IAS Annual Meeting on Conference Record of the Industry Applications Conference, 2003..

[3]  George K. Karagiannidis,et al.  Big Data Analytics for Dynamic Energy Management in Smart Grids , 2015, Big Data Res..

[4]  A. Golubev,et al.  Advantages of continuous monitoring of partial discharges in rotating equipment and switchgear , 2003, Conference Record of the 2003 Annual Pulp and Paper Industry Technical Conference, 2003..

[5]  Javier Ortego,et al.  Application of HFCT and UHF Sensors in On-Line Partial Discharge Measurements for Insulation Diagnosis of High Voltage Equipment , 2015, Sensors.

[6]  V. M. Catterson,et al.  The impact of smart grid technology on dielectrics and electrical insulation , 2015, IEEE Transactions on Dielectrics and Electrical Insulation.

[7]  Lanlan Li,et al.  Compression of smart meter big data: A survey , 2018, Renewable and Sustainable Energy Reviews.

[8]  Hong Wang,et al.  A Review of Online Partial Discharge Measurement of Large Generators , 2017 .

[9]  R. J. Brunt Physics and chemistry of partial discharge and corona. Recent advances and future challenges , 1994 .

[10]  Kimmo Kauhaniemi,et al.  Online condition monitoring of MV cable feeders using Rogowski coil sensors for PD measurements , 2019, Electric Power Systems Research.

[11]  Ricardo Albarracín Sánchez,et al.  Separation of Partial Discharge Sources Measured in the High-Frequency Range with HFCT Sensors Using PRPD-teff Patterns , 2020, Sensors.

[12]  Patrick Mulroy,et al.  CONTINUOUS ONLINE MONITORING OF PD ACTIVITY IN THE MEDIUM VOLTAGE DISTRIBUTION NETWORK , 2013 .

[13]  Ivo Palu,et al.  Identification and Location of PD Defects in Medium voltage Underground Power Cables Using High Frequency Current Transformer , 2019, IEEE Access.

[14]  G. Robles,et al.  A Partial Discharges acquisition and statistical analysis software , 2012, 2012 IEEE International Instrumentation and Measurement Technology Conference Proceedings.

[15]  Li Zhao,et al.  Design and Implementation of Data Acquisition for Partial Discharge in Power Cable , 2011 .

[16]  Alireza Ghasempour,et al.  Internet of Things in Smart Grid: Architecture, Applications, Services, Key Technologies, and Challenges , 2019, Inventions.

[17]  Markus Zdrallek,et al.  Economical and practicable condition assessment of MV- and LV-distribution grids , 2017 .

[18]  V. Fuster,et al.  Localization techniques of partial discharges at cable ends in off-line single-sided partial discharge cable measurements , 2016, IEEE Transactions on Dielectrics and Electrical Insulation.

[19]  G. Robles,et al.  Partial discharge signal propagation in medium voltage branched cable feeder , 2018, IEEE Electrical Insulation Magazine.

[20]  S. Bahadoorsingh,et al.  A Framework Linking Knowledge of Insulation Aging to Asset Management - [Feature Article] , 2008, IEEE Electrical Insulation Magazine.

[21]  F. Munoz,et al.  Effect of acquisition parameters on equivalent time and equivalent bandwidth algorithms for partial discharge clustering , 2017 .

[22]  R. S. Nema,et al.  Characterisation of partial discharge pulses in artificial voids in polypropylene films used in capacitors , 1996, Conference Record of the 1996 IEEE International Symposium on Electrical Insulation.

[23]  Yu-Min Hsueh,et al.  Development of a High-Speed Data Acquisition Card for Partial Discharge Measurement , 2019, IEEE Access.

[24]  Luis Hernández-Callejo,et al.  A Comprehensive Review of Operation and Control, Maintenance and Lifespan Management, Grid Planning and Design, and Metering in Smart Grids , 2019, Energies.